1SDA100580R1 ABB Ekip Dip LS/I 400A XT5 3-Pole Electronic Trip Unit

1SDA100580R1 ABB Ekip Dip LS/I 400A XT5 3-Pole Electronic Trip Unit

ABB 1SDA100580R1 is a 400 A three-pole Ekip Dip LS/I solid-state electronic trip unit for configurable SACE Tmax XT5 power distribution circuit breakers.

SKU: 1SDA100580R1MPN: 1SDA100580R1
Price
List Price £527.46 ex VAT
Your Price (ex VAT) Save 25%
£395.60 25% OFF
You save £131.87 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £395.60
Trade pricing is personalised to your account

Manufacturer Lead Time

£395.60

Why Choose the ABB 1SDA100580R1 Ekip Dip LS/I Trip Unit?

The ABB 1SDA100580R1 is a 400 A three-pole Ekip Dip LS/I solid-state electronic trip unit designed for the ABB SACE Tmax XT5 moulded case circuit breaker platform. Supplied as a separate protection release, it can be combined with a compatible three-pole XT5 breaking part to create a complete circuit breaker configuration for low-voltage power distribution.

Rated at 400 A, the Ekip Dip LS/I provides electronic long-time overload and short-circuit protection for AC distribution circuits. Its adjustable protection characteristics allow the circuit breaker configuration to be matched more closely to the protected conductors and downstream equipment while supporting selective coordination within the electrical distribution system.

Because the 1SDA100580R1 is supplied as the electronic trip unit rather than a complete MCCB, engineers and panel builders can select the required compatible XT5 breaking part independently. This modular approach allows the interruption performance of the breaking part and the 400 A Ekip Dip LS/I protection characteristics to be combined according to the requirements of the installation.

Key Advantages

  • Genuine ABB Ekip Dip electronic trip unit for SACE Tmax XT5 circuit breakers.
  • 400 A rated current for industrial AC power distribution applications.
  • LS/I electronic protection for overload and short-circuit conditions.
  • Adjustable protection characteristics support improved coordination with downstream circuits.
  • Three-pole configuration for three-phase electrical distribution systems.
  • Modular design allows pairing with a compatible three-pole ABB XT5 breaking part.

Key Features

  • ABB SACE Tmax XT series.
  • Ekip Dip LS/I electronic release.
  • 400 A rated current (In).
  • Three-pole configuration.
  • Solid-state electronic protection technology.
  • Designed for AC applications.
  • Long-time overload protection.
  • Short-circuit protection with configurable characteristics.
  • Separate/configurable trip-unit construction for use with an XT5 breaking part.
  • Designed for low-voltage power distribution protection.

Configurable Electronic Protection for Power Distribution

The ABB Ekip Dip LS/I platform provides electronic protection for low-voltage distribution circuits while allowing the protective release and circuit breaker breaking part to be selected separately. This modular architecture gives engineers flexibility when configuring an XT5 circuit breaker, particularly where a specific interruption performance and 400 A protection rating are required.

By combining the 1SDA100580R1 400 A three-pole Ekip Dip LS/I release with a compatible ABB XT5 three-pole breaking part, a complete MCCB can be configured for the required distribution application. This approach makes the trip unit suitable for switchboard manufacturing, system upgrades and replacement applications where the required XT5 breaking part is specified separately.

Typical Applications

  • Configurable ABB XT5 moulded case circuit breaker assemblies.
  • Industrial low-voltage power distribution.
  • Main and sub-distribution switchboards.
  • Three-phase feeder protection.
  • Manufacturing and process plant electrical systems.
  • Commercial and infrastructure distribution panels.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA100580R1
GTIN / EAN 8056221006569
Product type Electronic trip unit / protection release
Suitable for ABB SACE Tmax XT5
Application Power distribution protection
Rated current (In) 400 A
Number of poles 3
Current type AC
Trip unit Ekip Dip LS/I
Release technology Solid-state electronic
Protection function Long-time overload protection
Short-circuit protection Electronic short-circuit protection
Configuration Separate trip unit for configurable XT5 circuit breaker assemblies
Associated circuit breaker type Power distribution MCCB
Net weight approx. 1.395 kg

Frequently Asked Questions

What is the ABB 1SDA100580R1?

The ABB 1SDA100580R1 is a 400 A three-pole Ekip Dip LS/I solid-state electronic trip unit designed for configurable ABB SACE Tmax XT5 moulded case circuit breakers used in AC power distribution.

Is the ABB 1SDA100580R1 a complete circuit breaker?

No. The 1SDA100580R1 is the electronic protection trip unit. It is designed to be combined with a compatible three-pole ABB XT5 breaking part to create a complete moulded case circuit breaker assembly.

What is the rated current of the ABB 1SDA100580R1?

The Ekip Dip LS/I trip unit has a rated current of 400 A and is designed for the ABB SACE Tmax XT5 platform.

What protection does the ABB Ekip Dip LS/I provide?

The Ekip Dip LS/I provides electronic protection against sustained overloads and short-circuit conditions, with configurable protection characteristics that support coordination within low-voltage power distribution systems.

Which circuit breaker platform is the ABB 1SDA100580R1 designed for?

The 1SDA100580R1 is designed for the ABB SACE Tmax XT5 platform and is used with a compatible three-pole XT5 breaking part to configure a complete AC power distribution circuit breaker.

Trusted by Electrical Engineers Worldwide

ABB Ekip electronic trip units provide configurable solid-state protection for SACE Tmax XT moulded case circuit breakers, allowing engineers and switchboard manufacturers to combine the required protection characteristics with an appropriate breaking part for demanding low-voltage power distribution systems.