ABB 1SDA100541R1 XT5H 630 fixed four-pole moulded case circuit breaker with front terminals, a 630 A TMG thermomagnetic release and a 100% rated neutral for generator and demanding low-voltage distribution protection.

SKU: 1SDA100541R1MPN: 1SDA100541R1
Price
List Price £2,796.15 ex VAT
Your Price (ex VAT) Save 25%
£2,097.11 25% OFF
You save £699.04 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,097.11
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,097.11

Why Choose the ABB XT5H 630 TMG 630-3150 4p F F In=100%In?

The ABB 1SDA100541R1 is a high-performance Tmax XT5H moulded case circuit breaker (MCCB) designed for generator, transformer and demanding low-voltage distribution applications. Part of the ABB SACE Tmax XT series, this fixed four-pole circuit breaker combines an XT5 630 A frame with a TMG thermomagnetic trip unit rated at 630 A.

The TMG release combines thermal overload protection with magnetic short-circuit protection and is particularly suited to generator applications where fault currents can differ from those encountered in conventional utility-fed distribution systems. The 630–3150 A designation identifies the 630 A trip-unit rating and its magnetic protection level up to 3150 A.

With four-pole construction, a fully rated neutral at 100% of In, fixed mounting and front terminals, the XT5H 630 TMG is well suited to three-phase four-wire systems. The XT5H high breaking-capacity performance class provides robust fault interruption for industrial, commercial and infrastructure power systems.

Key Advantages

  • High-performance ABB Tmax XT5H moulded case circuit breaker for generator and power distribution protection.
  • 630 A TMG thermomagnetic trip unit provides overload and magnetic short-circuit protection.
  • 3150 A magnetic protection reference supports effective protection of generator-fed circuits.
  • Four-pole construction enables switching and protection across three-phase four-wire systems.
  • 100% rated neutral supports installations where the neutral conductor carries full rated current.
  • Fixed mounting with front terminals provides straightforward integration into low-voltage switchboards.

Key Features

  • ABB SACE Tmax XT5H circuit breaker.
  • 630 A frame and trip-unit rating.
  • TMG thermomagnetic release.
  • Thermal overload protection.
  • Magnetic short-circuit protection.
  • 3150 A magnetic protection reference.
  • Four-pole construction.
  • Neutral rating: 100% of In.
  • Fixed mounting configuration.
  • Front terminals for main circuit connections.
  • XT5 frame size with H short-circuit performance level.
  • Suitable for generator and demanding low-voltage distribution applications.

Dedicated Generator and Four-Pole Distribution Protection

Generator circuits can require different protection characteristics from conventional utility-fed distribution circuits because the available short-circuit current may be comparatively limited. The ABB TMG thermomagnetic release is designed to provide overload and magnetic short-circuit protection appropriate to these applications while retaining the straightforward operation and independence of a thermomagnetic trip unit.

The four-pole construction of the 1SDA100541R1 enables switching of all three phases and the neutral conductor, with the neutral rated at 100% of In. Combined with its 630 A rating, XT5H performance class, fixed mounting and front-terminal arrangement, this breaker is well suited to generator switchboards, standby power systems and substantial industrial or commercial distribution installations.

Typical Applications

  • Generator protection and generator switchboards.
  • Standby and emergency power systems.
  • Transformer and installation protection.
  • Three-phase four-wire distribution systems.
  • Industrial low-voltage switchboards.
  • Commercial and infrastructure power distribution.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Order code 1SDA100541R1
Product type Moulded case circuit breaker (MCCB)
Frame size XT5
Frame rating 630 A
Short-circuit performance level H
Trip-unit rated current (In) 630 A
Trip unit TMG thermomagnetic release
Protection functions Thermal overload and magnetic short-circuit protection
Magnetic protection reference 3150 A
Number of poles 4
Neutral rating 100% of In
Mounting Fixed
Terminal configuration Front terminals
Application Generator and low-voltage distribution protection

Frequently Asked Questions

What is the ABB 1SDA100541R1 used for?

The ABB 1SDA100541R1 is a Tmax XT5H four-pole moulded case circuit breaker with a TMG thermomagnetic release designed for generator, transformer and demanding low-voltage distribution protection.

What is the rated current of the ABB XT5H 630 TMG 630-3150?

The circuit breaker uses an XT5 630 A frame and is fitted with a 630 A TMG thermomagnetic trip unit.

What protection does the TMG trip unit provide?

The TMG thermomagnetic release provides thermal protection against sustained overloads together with magnetic protection for rapid interruption of short-circuit currents.

What does In=100%In mean on the ABB 1SDA100541R1?

The 100% In designation indicates that the neutral is fully rated relative to the trip-unit current, making this four-pole breaker suitable for systems requiring a full-current neutral conductor.

How is the ABB 1SDA100541R1 installed?

This model is a fixed four-pole circuit breaker with front terminals, making it suitable for integration into compatible generator panels, industrial switchboards and low-voltage distribution assemblies.

Trusted Generator and Circuit Protection from ABB

ABB SACE Tmax XT moulded case circuit breakers combine compact construction, application-specific protection and robust fault interruption for generator, transformer and demanding industrial or commercial low-voltage power systems.