1SDA100023R1 ABB XT2N 160 Ekip Dip LSIG In=100A 4P Moulded Case Circuit Breaker

1SDA100023R1 ABB XT2N 160 Ekip Dip LSIG In=100A 4P Moulded Case Circuit Breaker

ABB 1SDA100023R1 is an XT2N 160 four-pole fixed moulded case circuit breaker with front terminals, a 100 A Ekip Dip electronic trip unit providing LSIG protection and a 36 kA breaking capacity at 415 V AC.

SKU: 1SDA100023R1MPN: 1SDA100023R1
Price
List Price £1,990.72 ex VAT
Your Price (ex VAT) Save 25%
£1,493.04 25% OFF
You save £497.68 per unit
Manufacturer Lead Time Estimated Delivery 3 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,493.04
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,493.04

Why Choose the ABB XT2N 160 Ekip Dip LSIG In=100A 4P Circuit Breaker?

The ABB XT2N 160 Ekip Dip LSIG In=100A 4P, order code 1SDA100023R1, is a compact and versatile moulded case circuit breaker (MCCB) from the ABB SACE Tmax XT range. Designed for low-voltage power distribution, it combines the XT2N 160 frame with an Ekip Dip LSIG electronic trip unit rated at 100 A.

The Ekip Dip LSIG trip unit provides long-time (L), short-time (S), instantaneous (I) and earth-fault (G) protection. These electronic protection functions enable the breaker to respond to overloads, selective short-circuit conditions, severe instantaneous faults and earth faults, making it suitable for coordinated protection in industrial and commercial distribution systems.

The 1SDA100023R1 is supplied as a four-pole fixed circuit breaker with front terminals. The XT2N performance level provides a rated ultimate and service short-circuit breaking capacity of 36 kA at 415 V AC, while the breaker supports operational voltages up to 690 V AC.

Key Advantages

  • Compact ABB SACE Tmax XT2 moulded case circuit breaker.
  • 100 A Ekip Dip electronic trip unit for advanced circuit protection.
  • LSIG functionality provides overload, short-time, instantaneous and earth-fault protection.
  • 36 kA Icu and Ics at 415 V AC.
  • Four-pole configuration for applications requiring four-pole switching and protection.
  • 690 V AC rated operational voltage for a broad range of low-voltage systems.
  • Fixed execution with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax XT2N 160 platform.
  • 100 A rated current.
  • Ekip Dip electronic trip unit.
  • LSIG protection functions.
  • L – Long-time overload protection.
  • S – Short-time short-circuit protection.
  • I – Instantaneous short-circuit protection.
  • G – Earth-fault protection.
  • N short-circuit performance level.
  • 36 kA breaking capacity at 415 V AC.
  • 4-pole fixed configuration with front terminals.
  • Designed to IEC 60947-2 requirements.

Advanced LSIG Electronic Protection with Ekip Dip

The ABB Ekip Dip LSIG trip unit provides four complementary protection functions within the XT2N circuit breaker. Long-time protection responds to sustained overloads, short-time protection supports selective coordination during short-circuit events, instantaneous protection provides rapid operation under severe faults, and the G function provides dedicated earth-fault protection.

The Ekip Dip platform also incorporates features such as thermal memory and front fault indication, supporting effective operation and fault assessment in modern distribution systems. Combined with a 100 A rated trip unit, 36 kA breaking capacity at 415 V AC and four-pole construction, the ABB 1SDA100023R1 provides a comprehensive protection solution for demanding low-voltage installations.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Commercial building power distribution.
  • Four-pole feeder and branch-circuit protection.
  • Circuits requiring earth-fault protection.
  • Switchboards requiring selective short-circuit coordination.
  • Industrial machinery and process equipment.
  • OEM electrical distribution assemblies.

Technical Specifications

Series SACE Tmax XT
ABB order code 1SDA100023R1
Product type Moulded case circuit breaker
Frame XT2N
Frame size / rated uninterrupted current 160 A
Rated trip-unit current (In) 100 A
Trip unit Ekip Dip electronic
Protection functions LSIG
Long-time protection L
Short-time protection S
Instantaneous protection I
Earth-fault protection G
Short-circuit performance level N
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 36 kA
Rated service short-circuit breaking capacity (Ics) at 415 V AC 36 kA
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V AC
Rated impulse withstand voltage 8 kV
Rated frequency 50/60 Hz
Number of poles 4
Mounting execution Fixed
Terminal arrangement Front terminals
Standard IEC 60947-2
Electrical durability 8,000 cycles
Mechanical durability 25,000 cycles
EAN 8056221000789

Frequently Asked Questions

What is the ABB 1SDA100023R1?

The ABB 1SDA100023R1 is an XT2N 160 four-pole fixed moulded case circuit breaker with front terminals and a 100 A Ekip Dip LSIG electronic trip unit.

What is the rated current of the ABB XT2N 160 1SDA100023R1?

The Ekip Dip electronic trip unit is rated at 100 A, while the XT2 frame has a rated uninterrupted current of 160 A.

What does LSIG mean on the ABB Ekip Dip trip unit?

LSIG represents long-time, short-time, instantaneous and earth-fault protection, providing comprehensive electronic protection against overloads and several types of electrical fault.

Does the ABB 1SDA100023R1 provide earth-fault protection?

Yes. The G function within the Ekip Dip LSIG trip unit provides dedicated earth-fault protection.

What is the breaking capacity of the ABB XT2N 160 1SDA100023R1?

The XT2N configuration has rated ultimate and service short-circuit breaking capacities of 36 kA at 415 V AC.

What is the rated operational voltage of the ABB 1SDA100023R1?

The circuit breaker has a rated operational voltage of up to 690 V AC.

How is the ABB XT2N 160 1SDA100023R1 installed?

This model is supplied as a four-pole fixed circuit breaker with front terminals for integration into compatible switchboards, distribution panels and industrial electrical assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are used by panel builders, electrical engineers, machine builders and OEMs for advanced overload, short-circuit and earth-fault protection in demanding commercial and industrial low-voltage distribution systems.