Why Choose the ABB 1SDA074278R1 800 A L OFF Rating Plug?

The ABB 1SDA074278R1 is an 800 A L OFF rating plug designed for compatible ABB SACE Emax 2 air circuit breakers and Ekip electronic trip units. As part of the ABB Emax 2 circuit breaker accessory range, this genuine ABB component provides an 800 A rated-current configuration for suitable protection applications.

Designed for E1.2 through E6.2 Emax 2 frame sizes, the 1SDA074278R1 combines an 800 A rating with an L OFF configuration. This configuration is intended for compatible applications where the long-time overcurrent protection function is disabled, while the applicable protection functions provided by the Ekip trip unit remain available.

The 1SDA074278R1 is the installed version of the 800 A L OFF rating plug. Its compatibility across the E1.2, E2.2, E4.2 and E6.2 Emax 2 frame range makes it suitable for factory-configured switchgear and circuit breaker assemblies requiring an installed 800 A L OFF rating plug.

Key Advantages

  • Genuine ABB Emax 2 rating plug for compatible Ekip protection units.
  • 800 A rated-current configuration for compatible circuit breaker applications.
  • L OFF configuration for applications where long-time overcurrent protection is disabled.
  • Suitable for ABB SACE Emax 2 E1.2 through E6.2 frame sizes.
  • Installed configuration for integration with compatible circuit breaker assemblies.
  • Purpose-designed ABB accessory for dependable compatibility within the Emax 2 protection system.

Key Features

  • ABB SACE Emax 2 accessory.
  • 800 A rating plug.
  • L OFF protection configuration.
  • Designed for compatible ABB Ekip electronic trip units.
  • Suitable for E1.2, E2.2, E4.2 and E6.2 Emax 2 frame sizes.
  • Designed for applications requiring the long-time protection function to be disabled.
  • Installed version.
  • ABB order code 1SDA074278R1.

Configurable Protection for Emax 2 Circuit Breakers

Rating plugs form part of the configurable protection architecture used with ABB Ekip electronic trip units. They provide the rated-current reference required by the compatible protection configuration, helping match the circuit breaker and trip unit to the requirements of the low-voltage electrical distribution system.

The ABB 1SDA074278R1 provides an 800 A current rating together with an L OFF configuration. It is intended for compatible Emax 2 applications where the long-time overcurrent protection function is disabled and provides an installed manufacturer-specified configuration across E1.2 through E6.2 circuit breaker frames.

Typical Applications

  • ABB SACE Emax 2 air circuit breaker installations.
  • E1.2, E2.2, E4.2 and E6.2 breaker configurations.
  • Compatible ABB Ekip electronic trip units.
  • Low-voltage switchboards and power distribution systems.
  • Industrial installations requiring an 800 A L OFF protection configuration.
  • Factory-configured switchgear and circuit breaker assemblies.

Technical Specifications

Series SACE Emax 2
Model / order code 1SDA074278R1
Product type L OFF rating plug
Rated current 800 A
Protection configuration L OFF
Compatible circuit breaker frames E1.2, E2.2, E4.2 and E6.2
Compatible product family ABB SACE Emax 2 air circuit breakers
Trip unit type Compatible ABB Ekip electronic protection units
Supply configuration Installed

Frequently Asked Questions

What is the ABB 1SDA074278R1 used for?

The ABB 1SDA074278R1 is an 800 A L OFF rating plug installed with compatible Ekip electronic trip units in ABB SACE Emax 2 air circuit breaker applications.

What is the current rating of the ABB 1SDA074278R1?

The 1SDA074278R1 has a rated current of 800 A.

Which Emax 2 circuit breaker sizes are compatible with this rating plug?

ABB specifies the 1SDA074278R1 for compatible E1.2, E2.2, E4.2 and E6.2 SACE Emax 2 circuit breaker frames.

What does L OFF mean on the ABB 1SDA074278R1?

L OFF identifies a rating-plug configuration for compatible applications where the long-time overcurrent protection function is disabled.

Is the ABB 1SDA074278R1 supplied loose or installed?

The 1SDA074278R1 is specified as the installed version of the 800 A L OFF rating plug for compatible ABB SACE Emax 2 applications.

Trusted ABB Circuit Breaker Accessories

ABB SACE Emax 2 rating plugs provide dedicated rated-current and protection configurations for compatible Ekip electronic trip units, supporting flexible circuit protection across low-voltage switchgear and industrial power distribution systems.