1SDA074043R1 ABB Emax 2 E6.2 6300 A VR/HR Terminal Kit 4-Pole

1SDA074043R1 ABB Emax 2 E6.2 6300 A VR/HR Terminal Kit 4-Pole

ABB 1SDA074043R1 is a four-piece vertical rear/horizontal rear terminal kit for four-pole SACE Emax 2 E6.2 air circuit-breaker applications with a rated uninterrupted current of 6300 A.

SKU: 1SDA074043R1MPN: 1SDA074043R1
Price
List Price £1,573.88 ex VAT
Your Price (ex VAT) Save 25%
£1,180.41 25% OFF
You save £393.47 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,180.41
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,180.41

Why Choose the ABB 1SDA074043R1 Emax 2 VR/HR Terminal Kit?

The ABB 1SDA074043R1 is a genuine four-pole vertical rear/horizontal rear terminal kit for ABB SACE Emax 2 E6.2 air circuit breakers with a rated uninterrupted current of 6300 A. Identified by ABB as KIT VR/HR E6.2 IU=6300 4PCS, it provides four main-circuit terminal assemblies for high-current switchgear connections.

The VR/HR terminal arrangement supports rear connection geometry for integrating the breaker with the switchboard busbar system. Vertical rear and horizontal rear arrangements give panel designers flexibility when matching the circuit breaker to the physical routing and orientation of high-current busbars within a low-voltage assembly.

Supplied as a four-piece kit, the 1SDA074043R1 is intended for a four-pole E6.2 installation rated at 6300 A. Its ABB-engineered construction provides a purpose-designed main-circuit interface for demanding industrial, infrastructure and critical-power distribution applications.

Key Advantages

  • Genuine ABB SACE Emax 2 terminal accessory.
  • Designed specifically for high-current E6.2 6300 A applications.
  • Supports vertical rear / horizontal rear connection arrangements.
  • Supplied as a four-piece kit for four-pole installations.
  • Rear connection geometry supports efficient integration with switchboard busbars.
  • Purpose-designed for demanding low-voltage power-distribution assemblies.
  • ABB-engineered compatibility with the specified Emax 2 breaker platform.

Key Features

  • ABB SACE Emax 2 accessory.
  • VR/HR rear terminal configuration.
  • Vertical rear / horizontal rear connection arrangement.
  • Designed for the E6.2 breaker frame.
  • Rated uninterrupted current application: 6300 A.
  • Four-piece kit.
  • Suitable for a four-pole circuit-breaker configuration.
  • Designed for main-circuit busbar connections.
  • Suitable for high-current low-voltage switchgear applications.

Flexible High-Current Rear Connections

Large-frame air circuit breakers require robust main-circuit connections capable of integrating with substantial switchboard busbar systems. Rear terminal arrangements keep these high-current connections behind the breaker and allow the busbar architecture to be designed around the available switchgear space and required conductor routing.

The ABB 1SDA074043R1 provides four VR/HR terminal assemblies for a four-pole E6.2 application with an uninterrupted current rating of 6300 A. This makes the kit suitable for high-capacity distribution assemblies where the breaker must interface with vertically or horizontally arranged rear busbars.

Typical Applications

  • ABB SACE Emax 2 E6.2 air circuit-breaker installations.
  • Four-pole 6300 A low-voltage distribution systems.
  • Switchgear with vertical or horizontal rear busbar connections.
  • Industrial main power-distribution boards.
  • Transformer incomer and outgoing feeder switchgear.
  • Generator and critical-power distribution systems.
  • Data centre and infrastructure electrical distribution.
  • OEM high-current switchboard assemblies.

Technical Specifications

Series SACE Emax 2
Order code 1SDA074043R1
Product designation KIT VR/HR E6.2 IU=6300 4PCS
Product type Main-circuit terminal kit
Terminal arrangement Vertical rear / horizontal rear (VR/HR)
Compatible breaker frame E6.2
Rated uninterrupted current (Iu) 6300 A
Number of poles 4
Number of terminal assemblies 4
Application High-current rear main-circuit connections
ABB product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA074043R1 used for?

The ABB 1SDA074043R1 is a four-piece VR/HR terminal kit for ABB SACE Emax 2 E6.2 air circuit breakers with a rated uninterrupted current of 6300 A, providing the main-circuit connection interface for a four-pole installation.

What does VR/HR mean on ABB 1SDA074043R1?

VR/HR identifies vertical rear / horizontal rear terminal arrangements used to connect the circuit breaker to the rear busbar system of compatible switchgear.

What current rating is the ABB 1SDA074043R1 designed for?

The product designation specifies an E6.2 application with a rated uninterrupted current, Iu, of 6300 A.

How many terminals are included in ABB 1SDA074043R1?

The kit contains four terminal assemblies and is intended for a four-pole circuit-breaker configuration.

Which breaker frame is ABB 1SDA074043R1 designed for?

The 1SDA074043R1 is specifically identified for the ABB SACE Emax 2 E6.2 air circuit-breaker frame.

Engineered for ABB High-Current Power Distribution Systems

ABB SACE Emax 2 terminal accessories provide purpose-designed main-circuit connection options for high-current air circuit breakers, helping switchboard builders integrate large-frame breakers with the required rear busbar architecture.