1SDA073378R1 ABB E6.2V/f 6300 Ekip Hi-Touch LSI 4p WMP Air Circuit Breaker

1SDA073378R1 ABB E6.2V/f 6300 Ekip Hi-Touch LSI 4p WMP Air Circuit Breaker

ABB 1SDA073378R1 E6.2V/f 6300 Ekip Hi-Touch LSI 4p WMP is a 6300 A four-pole full-size withdrawable Emax 2 air circuit breaker moving part with advanced long-time, short-time and instantaneous electronic protection for high-fault-level low-voltage power distribution systems.

SKU: 1SDA073378R1MPN: 1SDA073378R1
Price
List Price £76,126.52 ex VAT
Your Price (ex VAT) Save 25%
£57,094.89 25% OFF
You save £19,031.63 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £57,094.89
Trade pricing is personalised to your account

Manufacturer Lead Time

£57,094.89

Why Choose the ABB E6.2V/f 6300 Ekip Hi-Touch LSI 4p WMP Air Circuit Breaker?

The ABB E6.2V/f 6300 Ekip Hi-Touch LSI 4p WMP, order code 1SDA073378R1, is a high-performance four-pole withdrawable air circuit breaker moving part from the ABB SACE Emax 2 range. Designed for very high-current low-voltage distribution systems, it combines a rated uninterrupted current of 6300 A with the advanced Ekip Hi-Touch LSI electronic trip unit for long-time overload, short-time selective short-circuit and instantaneous short-circuit protection.

The E6.2V/f full-size platform is engineered for critical switchboards requiring exceptionally high fault-clearing performance. Its V performance level provides a rated ultimate short-circuit breaking capacity of 150 kA at 440 V AC, while a rated short-time withstand current of 100 kA for 1 s supports selective coordination in complex industrial and infrastructure power networks.

The Ekip Hi-Touch release provides advanced protection, measurement and monitoring functionality through an intuitive interface, giving operators greater visibility and control over critical electrical systems. The withdrawable moving-part architecture enables the breaker to be used with the appropriate ABB Emax 2 fixed part, supporting efficient inspection, servicing and replacement where continuity of service is important.

Key Advantages

  • Very high-capacity 6300 A four-pole air circuit breaker for demanding low-voltage distribution systems.
  • Ekip Hi-Touch LSI electronic trip unit provides advanced long-time, short-time and instantaneous protection.
  • 150 kA rated ultimate short-circuit breaking capacity at 440 V AC for high-fault-level installations.
  • 100 kA short-time withstand current for 1 s supports selective protection and system coordination.
  • Adjustable overload protection from 2520–6300 A.
  • Adjustable short-time protection from 3780–63000 A.
  • Adjustable instantaneous protection from 9450–94500 A.
  • Advanced Hi-Touch functionality supports sophisticated protection, measurement and monitoring requirements.
  • Withdrawable moving-part design facilitates inspection, maintenance and replacement.
  • Part of the proven ABB SACE Emax 2 air circuit breaker platform.

Key Features

  • ABB SACE Emax 2 E6.2V/f full-size air circuit breaker.
  • 6300 A rated uninterrupted current.
  • Four-pole (4P) configuration with full-size neutral.
  • Ekip Hi-Touch LSI solid-state electronic protection release.
  • Long-time (L) overload protection.
  • Short-time (S) selective short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • 690 V AC rated voltage.
  • 150 kA rated ultimate short-circuit breaking capacity at 440 V AC.
  • 100 kA rated short-time withstand current for 1 s.
  • 2520–6300 A overload release adjustment range.
  • 3780–63000 A short-time delayed short-circuit adjustment range.
  • 9450–94500 A instantaneous short-circuit adjustment range.
  • Four change-over auxiliary contacts.
  • Open/closed circuit breaker position indication.
  • Optional motor drive.
  • Withdrawable moving part (WMP) configuration.

Advanced Protection for High-Fault-Level Power Distribution

The ABB Emax 2 E6.2V/f platform is designed for electrical systems where exceptionally high continuous current and fault-clearing performance are required. Combining a 6300 A current rating, 150 kA ultimate short-circuit breaking capacity at 440 V AC and 100 kA short-time withstand capability, this breaker is particularly suited to main incomers, transformer secondary circuits, bus couplers and other critical high-current circuits.

The Ekip Hi-Touch LSI electronic release combines adjustable long-time overload, short-time selective and instantaneous short-circuit protection with advanced monitoring functionality. Together with the Emax 2 withdrawable architecture, this provides a powerful protection solution for installations where electrical selectivity, system visibility, high availability and maintainability are key requirements.

Typical Applications

  • Main incomers in very high-current low-voltage switchboards.
  • Industrial power distribution systems.
  • Transformer secondary protection.
  • Bus couplers and bus-tie circuit breaker applications.
  • Data centres and critical power infrastructure.
  • Large commercial buildings and infrastructure facilities.
  • Manufacturing plants and process industries.
  • Utility and energy distribution systems.
  • High-fault-level switchgear requiring advanced selective protection.
  • Critical distribution systems requiring advanced protection and monitoring capabilities.

Technical Specifications

Series SACE Emax 2
Product group Emax2 Air Circuit Breaker
Frame / type E6.2V/f
Order code / MPN 1SDA073378R1
EAN / GTIN 8015644772284
Product type Air circuit breaker moving part
Construction Full-size, withdrawable
Rated uninterrupted current (Iu) 6300 A
Number of poles 4P
Neutral configuration Full-size neutral
Current type AC
Trip unit Ekip Hi-Touch LSI
Release type Solid-state electronic
Protection functions L (long-time), S (short-time), I (instantaneous)
Overload release setting range 2520–6300 A
Short-time delayed short-circuit setting range 3780–63000 A
Instantaneous short-circuit setting range 9450–94500 A
Rated voltage 690 V AC
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 150 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 150 kA
Rated short-time withstand current (Icw), 1 s 100 kA
Short-circuit performance level V
Integrated earth-fault protection No
Auxiliary contacts 4 change-over contacts
Circuit breaker indication Open/closed position
Integrated motor drive No
Optional motor drive Yes
Main circuit connection Connection via separate fixed chassis part
Installation Withdrawable
Configuration Moving part (WMP)

Frequently Asked Questions

What is the ABB 1SDA073378R1 used for?

The ABB 1SDA073378R1 is a 6300 A four-pole Emax 2 air circuit breaker moving part designed for protection, switching and isolation in very high-current, high-fault-level low-voltage electrical distribution systems.

What protection functions does the Ekip Hi-Touch LSI trip unit provide?

The Ekip Hi-Touch LSI electronic trip unit provides long-time overload (L), short-time selective short-circuit (S) and instantaneous short-circuit (I) protection, together with advanced monitoring and measurement functionality.

What is the breaking capacity of the ABB 1SDA073378R1?

The E6.2V/f 6300 provides a rated ultimate short-circuit breaking capacity of 150 kA at 400 V AC and 440 V AC, making it suitable for demanding installations with very high prospective fault currents.

Does the ABB 1SDA073378R1 include earth-fault protection?

No. The Ekip Hi-Touch LSI release provides long-time, short-time and instantaneous overcurrent protection. An LSIG-equipped Emax 2 version should be selected where integrated earth-fault protection is required.

Is the ABB 1SDA073378R1 a withdrawable circuit breaker?

Yes. The 1SDA073378R1 is the moving part of a withdrawable ABB Emax 2 air circuit breaker and is designed for use with the appropriate compatible Emax 2 fixed part.

Trusted Protection for High-Current Power Systems

ABB SACE Emax 2 air circuit breakers combine very high current capability, advanced electronic protection, exceptional short-circuit performance and maintainable withdrawable architecture for demanding industrial, commercial and critical low-voltage power distribution applications.