1SDA072176R1 ABB E1.2B 1250 Ekip Touch LSIG 3p WMP Air Circuit Breaker

1SDA072176R1 ABB E1.2B 1250 Ekip Touch LSIG 3p WMP Air Circuit Breaker

ABB 1SDA072176R1 E1.2B 1250 Ekip Touch LSIG three-pole withdrawable air circuit breaker moving part with a 1250 A rated current, 42 kA breaking capacity and touchscreen-configurable long-time, short-time, instantaneous and earth-fault protection.

SKU: 1SDA072176R1MPN: 1SDA072176R1
Price
List Price £4,754.90 ex VAT
Your Price (ex VAT) Save 25%
£3,566.18 25% OFF
You save £1,188.73 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,566.18
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,566.18

Why Choose the ABB E1.2B 1250 Ekip Touch LSIG 3p WMP Air Circuit Breaker?

The ABB E1.2B 1250 Ekip Touch LSIG 3p WMP, order code 1SDA072176R1, is a compact air circuit breaker (ACB) moving part from the ABB SACE Emax 2 series, designed for switching and comprehensive protection in low-voltage power distribution systems. With a rated uninterrupted current of 1250 A, three-pole construction and ABB's Ekip Touch electronic trip technology, it provides dependable protection for industrial, commercial and infrastructure electrical installations.

The Ekip Touch LSIG electronic trip unit provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection. Its touchscreen interface provides convenient access to protection settings and operating information, while the combination of L, S, I and G functions supports selective coordination and comprehensive fault protection within modern electrical distribution networks.

The 1SDA072176R1 is a withdrawable moving part (WMP) designed for use with the corresponding Emax 2 E1.2 fixed part. The E1.2B performance level provides a rated ultimate short-circuit breaking capacity of 42 kA, combining compact construction, comprehensive LSIG protection and convenient isolation for inspection and maintenance.

Key Advantages

  • Compact 1250 A Emax 2 air circuit breaker moving part for low-voltage power distribution.
  • Three-pole construction for three-phase AC electrical networks.
  • Ekip Touch LSIG electronic trip unit provides comprehensive overload, short-circuit and earth-fault protection.
  • Integrated long-time, short-time, instantaneous and earth-fault protection.
  • 42 kA ultimate short-circuit breaking capacity for dependable fault interruption.
  • Long-time overload protection adjustable from 500–1250 A.
  • Instantaneous protection adjustable from 1875–18750 A.
  • Touchscreen interface provides convenient configuration and access to protection information.
  • Withdrawable moving-part design facilitates isolation, inspection and maintenance when used with the corresponding fixed part.

Key Features

  • ABB SACE Emax 2 E1.2B series.
  • 1250 A rated uninterrupted current.
  • Three-pole construction.
  • Ekip Touch LSIG electronic trip unit.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • Integrated earth-fault protection.
  • Touchscreen interface for protection configuration and electrical information.
  • 500–1250 A long-time protection adjustment range.
  • 1875–18750 A instantaneous protection adjustment range.
  • 42 kA ultimate short-circuit breaking capacity.
  • Withdrawable moving part for integration with the corresponding Emax 2 fixed part.
  • Compact E1.2 frame for space-efficient low-voltage switchgear.

Comprehensive LSIG Protection for Low-Voltage Distribution

Air circuit breakers such as the ABB SACE Emax 2 E1.2B provide switching, isolation and protection for low-voltage electrical distribution circuits. The compact E1.2 architecture combines substantial fault-clearing capability with a withdrawable construction, allowing the breaker moving part to be disconnected from its corresponding fixed part for inspection, servicing or replacement.

The Ekip Touch LSIG electronic trip unit combines adjustable long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection. This comprehensive protection arrangement supports selective distribution system design while providing protection against overloads, severe short circuits and earth-fault conditions, with settings accessible through the touchscreen interface.

Typical Applications

  • Low-voltage power distribution switchboards.
  • Industrial electrical distribution systems.
  • Commercial building power distribution.
  • Manufacturing and process installations.
  • Incoming and feeder circuit protection.
  • Three-phase circuits requiring 1250 A rated protection.
  • Distribution systems requiring comprehensive LSIG and earth-fault protection.
  • Applications requiring touchscreen-configurable electronic protection.
  • Networks requiring selective short-circuit protection.
  • Withdrawable switchgear requiring convenient isolation and maintenance.

Technical Specifications

Series SACE Emax 2
Product group Emax2 Air Circuit Breaker
Order code / MPN 1SDA072176R1
Product type Air circuit breaker moving part
Frame E1.2
Performance level B
Rated uninterrupted current 1250 A
Rated ultimate short-circuit breaking capacity 42 kA
Number of poles 3
Trip unit Ekip Touch LSIG
Release type Electronic trip unit
Protection functions LSIG (long-time, short-time, instantaneous and earth-fault)
Long-time overload protection adjustment range 500–1250 A
Instantaneous protection adjustment range 1875–18750 A
Long-time overload protection Yes
Short-time delayed short-circuit protection Yes
Instantaneous short-circuit protection Yes
Integrated earth-fault protection Yes
Configuration interface Touchscreen
Installation Withdrawable
Component type Moving part (WMP)
Applicable standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA072176R1 used for?

The ABB 1SDA072176R1 is the withdrawable moving part of an Emax 2 E1.2B air circuit breaker, designed for switching and comprehensive protection of three-phase low-voltage power distribution circuits.

What is the current rating of the ABB E1.2B 1250?

The circuit breaker has a rated uninterrupted current of 1250 A, with long-time overload protection adjustable from 500–1250 A.

What protection does the Ekip Touch LSIG trip unit provide?

The Ekip Touch LSIG electronic trip unit provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection, with settings accessible through its touchscreen interface.

What is the breaking capacity of the ABB E1.2B 1250?

The E1.2B 1250 has a rated ultimate short-circuit breaking capacity of 42 kA, providing dependable short-circuit protection for low-voltage distribution systems.

Is the ABB 1SDA072176R1 fixed or withdrawable?

The 1SDA072176R1 is a withdrawable moving part (WMP) designed for installation with the corresponding ABB Emax 2 fixed part.

Trusted Power Protection from ABB

ABB SACE Emax 2 air circuit breakers provide reliable switching and advanced electronic protection for modern low-voltage power distribution systems, combining compact construction, flexible installation and comprehensive circuit protection technology.