ABB 1SDA072107R1 Emax 2 E1.2C 800 three-pole withdrawable air circuit breaker moving part with an 800 A rated current, 50 kA breaking capacity at 400–440 V AC and Ekip G Touch LSIG electronic protection for power distribution and generator applications.
£5,597.54
The ABB E1.2C 800 Ekip G Touch LSIG 3p WMP, order code 1SDA072107R1, is a withdrawable Emax 2 air circuit breaker (ACB) designed for advanced protection and switching in low-voltage power distribution and generator applications. As part of the ABB SACE Emax 2 series, this three-pole moving part combines an 800 A rated uninterrupted current with the Ekip G Touch LSIG electronic trip unit for comprehensive circuit and generator protection.
The compact E1.2C platform provides high short-circuit performance for industrial, commercial and power-generation switchboards. Its Ekip G Touch LSIG electronic release provides long-time, short-time, instantaneous and ground-fault protection, while the generator-oriented Ekip G platform adds functions designed for the protection and management of generating sets and complex power networks.
With an 800 A current rating, three-pole configuration, ultimate short-circuit breaking capacity of 50 kA at 400–440 V AC and rated short-time withstand current of 42 kA for 1 s, the E1.2C 800 is suited to demanding electrical systems. The WMP withdrawable moving-part configuration is designed for installation with the corresponding Emax 2 fixed part, supporting convenient isolation, testing and maintenance.
The ABB Emax 2 E1.2C combines high-performance circuit interruption with intelligent electronic protection for important low-voltage circuits. Its 50 kA breaking capacity at 400–440 V AC and 42 kA short-time withstand capability allow the breaker to protect distribution equipment while supporting selective coordination in installations with high prospective fault currents.
The Ekip G Touch LSIG trip unit is particularly suited to generator-connected systems. It combines adjustable long-time, short-time, instantaneous and ground-fault protection with generator-oriented functionality and an intuitive touchscreen interface. This makes the breaker suitable for installations where generating sets, utility supplies and critical loads must be protected and coordinated within the same low-voltage network.
| Product group | Emax2 Air Circuit Breaker |
|---|---|
| Series | SACE Emax 2 |
| ABB order code | 1SDA072107R1 |
| Product type | Air circuit breaker moving part |
| Frame | E1.2 |
| Short-circuit performance level | C |
| Rated uninterrupted current (Iu) | 800 A |
| Number of poles | 3 |
| Current type | AC |
| Rated operational voltage | up to 690 V AC |
| Ultimate short-circuit breaking capacity (Icu) | 50 kA at 400–440 V AC |
| Rated short-time withstand current (Icw) | 42 kA for 1 s |
| Trip unit | Ekip G Touch LSIG |
| Release type | Electronic / solid-state |
| Protection functions | Long-time, short-time, instantaneous and ground fault (LSIG) |
| Overload release adjustment | 320–800 A |
| Short-time delayed short-circuit adjustment | 480–8000 A |
| Instantaneous short-circuit adjustment | 1200–12000 A |
| Integrated earth-fault protection | Yes |
| Execution | Withdrawable moving part (WMP) |
| Auxiliary contacts | 4 change-over contacts |
| Motor drive | Optional |
| Standard | IEC |
| Application | Low-voltage power distribution and generator protection |
The ABB 1SDA072107R1 is an Emax 2 air circuit breaker moving part designed for switching and protecting three-phase low-voltage power distribution and generator circuits.
The circuit breaker has a rated uninterrupted current of 800 A.
The breaker uses an Ekip G Touch LSIG electronic trip unit providing long-time, short-time, instantaneous and ground-fault protection together with generator-oriented protection functionality.
The E1.2C 800 has an ultimate short-circuit breaking capacity of 50 kA at 400–440 V AC and 42 kA at 500–690 V AC, with a rated short-time withstand current of 42 kA for 1 s.
WMP identifies the withdrawable moving part of the circuit breaker, designed for installation with the corresponding fixed part in an ABB Emax 2 withdrawable switchgear assembly.
ABB SACE Emax 2 air circuit breakers combine high-performance low-voltage circuit protection with advanced electronic trip technology, generator-oriented functionality and flexible withdrawable switchgear integration for modern industrial, commercial and power-generation systems.