1SDA072100R1 ABB E1.2B 800 Ekip G Hi-Touch LSIG 3p WMP Air Circuit Breaker

1SDA072100R1 ABB E1.2B 800 Ekip G Hi-Touch LSIG 3p WMP Air Circuit Breaker

ABB 1SDA072100R1 is a SACE Emax 2 E1.2B 800 A three-pole withdrawable air circuit breaker moving part with Ekip G Hi-Touch LSIG electronic generator protection, a 690 V AC rating and 42 kA ultimate short-circuit breaking capacity at 440 V AC.

SKU: 1SDA072100R1MPN: 1SDA072100R1
Price
List Price £8,025.14 ex VAT
Your Price (ex VAT) Save 25%
£6,018.86 25% OFF
You save £2,006.29 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,018.86
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,018.86

Why Choose the ABB E1.2B 800 Ekip G Hi-Touch LSIG 3p WMP Air Circuit Breaker?

The ABB E1.2B 800 Ekip G Hi-Touch LSIG 3p WMP, order code 1SDA072100R1, is a high-performance SACE Emax 2 air circuit breaker moving part designed for generator protection and demanding low-voltage power distribution applications. Rated at 800 A, this three-pole unit incorporates ABB's advanced Ekip G Hi-Touch LSIG electronic trip release and is intended for use with the appropriate fixed part in a withdrawable Emax 2 installation.

The Ekip G Hi-Touch LSIG release combines long-time, short-time, instantaneous and ground-fault protection with advanced generator-oriented protection, measurement and supervision capabilities. This sophisticated platform supports selective protection, electrical monitoring and integration into modern generator switchboards and critical power systems.

The E1.2B performance level provides an ultimate short-circuit breaking capacity of 42 kA at 440 V AC and a rated short-time withstand current of 42 kA for 1 second. Its withdrawable moving-part configuration enables convenient isolation, inspection and maintenance when installed with the appropriate ABB Emax 2 fixed part.

Key Advantages

  • Advanced ABB SACE Emax 2 E1.2B air circuit breaker moving part.
  • 800 A rated current for generator and power distribution applications.
  • Three-pole configuration for three-phase electrical systems.
  • Ekip G Hi-Touch LSIG electronic trip unit with generator-oriented protection capabilities.
  • Long-time, short-time, instantaneous and ground-fault protection functions.
  • Advanced electrical measurement, monitoring and power-management capabilities.
  • 42 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 42 kA short-time withstand current for 1 second.
  • Moving-part configuration for compatible withdrawable Emax 2 installations.

Key Features

  • ABB SACE Emax 2 E1.2B series.
  • 800 A rated uninterrupted current.
  • Three-pole construction.
  • Ekip G Hi-Touch LSIG electronic protection release.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • Integrated ground-fault protection.
  • Generator-oriented protection and supervision functions.
  • 690 V AC rated operational voltage.
  • 42 kA Icu at 440 V AC.
  • 42 kA Icw for 1 second.
  • Moving part for withdrawable circuit-breaker installation.
  • Advanced Ekip measurement and monitoring capabilities.

Advanced Generator and Power Distribution Protection

ABB SACE Emax 2 air circuit breakers combine dependable fault interruption with sophisticated electronic protection, measurement and power-management capabilities. The Ekip G Hi-Touch LSIG release is specifically suited to generator applications while providing comprehensive protection against overloads, delayed and instantaneous short circuits and ground faults.

With its 800 A rating, 42 kA breaking capacity and withdrawable moving-part configuration, the 1SDA072100R1 is particularly suitable for generator switchboards, power-generation installations and critical distribution systems where advanced protection, system supervision and convenient maintenance access are required.

Typical Applications

  • Generator protection and generator switchboards.
  • Power generation and energy installations.
  • Low-voltage power distribution switchboards.
  • Withdrawable circuit-breaker assemblies.
  • Industrial electrical distribution systems.
  • Data centres and critical power infrastructure.

Technical Specifications

Series SACE Emax 2 E1.2B
Order code 1SDA072100R1
Product type Air circuit breaker moving part
Rated uninterrupted current (Iu) 800 A
Number of poles 3
Current type AC
Trip unit Ekip G Hi-Touch LSIG
Release type Electronic
Protection functions LSIG – long-time, short-time, instantaneous and ground-fault
Rated operational voltage 690 V AC
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 42 kA
Rated short-time withstand current (Icw), 1 s 42 kA
Integrated ground-fault protection Yes
Generator-oriented protection Yes
Execution Moving part for withdrawable installation
Product width 278 mm
Product depth 271 mm
Product weight 18 kg
Standards/approvals IEC

Frequently Asked Questions

What is the ABB 1SDA072100R1 used for?

The ABB 1SDA072100R1 is an Emax 2 E1.2B 800 air circuit breaker moving part designed for generator protection and low-voltage power distribution in compatible withdrawable switchgear.

What is the rated current of the ABB E1.2B 1SDA072100R1?

The circuit breaker moving part has a rated uninterrupted current of 800 A and is designed for AC systems with a rated operational voltage up to 690 V AC.

What protection does the Ekip G Hi-Touch LSIG trip unit provide?

The Ekip G Hi-Touch LSIG release provides long-time, short-time, instantaneous and ground-fault protection together with advanced generator-oriented protection, measurement and monitoring capabilities.

What is the breaking capacity of the ABB E1.2B 800?

The E1.2B 800 provides an ultimate short-circuit breaking capacity of 42 kA at 440 V AC and a rated short-time withstand current of 42 kA for 1 second.

How is the ABB 1SDA072100R1 installed?

The 1SDA072100R1 is the moving part of a withdrawable Emax 2 circuit breaker and is installed with the appropriate ABB E1.2 fixed part, allowing the breaker to be isolated and withdrawn for inspection or maintenance.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers combine dependable switching, advanced generator protection, electrical measurement and intelligent power-management capabilities for modern power generation, industrial and critical infrastructure systems.