1SDA071965R1 ABB E6.2V/f 4000 Ekip Touch LSI 4p FHR Air Circuit Breaker

1SDA071965R1 ABB E6.2V/f 4000 Ekip Touch LSI 4p FHR Air Circuit Breaker

ABB 1SDA071965R1 Emax 2 E6.2V/f 4000 Ekip Touch LSI four-pole fixed air circuit breaker with full-size neutral, rated at 4000 A and 690 V AC with up to 150 kA breaking capacity and adjustable long-time, short-time and instantaneous protection.

SKU: 1SDA071965R1MPN: 1SDA071965R1
Price
List Price £40,454.78 ex VAT
Your Price (ex VAT) Save 25%
£30,341.09 25% OFF
You save £10,113.70 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £30,341.09
Trade pricing is personalised to your account

Manufacturer Lead Time

£30,341.09

Why Choose the ABB E6.2V/f 4000 Ekip Touch LSI 4p FHR Air Circuit Breaker?

The ABB 1SDA071965R1 is a high-performance Emax 2 air circuit breaker (ACB) designed for protection, switching and isolation in demanding low-voltage power-distribution systems. Identified as the E6.2V/f 4000 Ekip Touch LSI 4p FHR, this four-pole fixed circuit breaker combines a 4000 A rated uninterrupted current with ABB’s advanced Ekip Touch LSI solid-state electronic trip unit.

As part of the ABB SACE Emax 2 E6.2V/f series, this breaker features a full-size neutral and exceptionally high short-circuit performance for critical industrial, commercial and infrastructure installations. The Ekip Touch LSI release provides adjustable long-time overload, short-time selective and instantaneous short-circuit protection, allowing protection characteristics to be coordinated with downstream devices.

With a rated operational voltage of 690 V AC, an ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC, 130 kA at 500–525 V AC and 100 kA at 690 V AC, the 1SDA071965R1 is engineered for systems with exceptionally high prospective fault currents. Its fixed construction and rear flat horizontal terminals provide a robust configuration for permanent integration into high-capacity low-voltage switchboards.

Key Advantages

  • High-performance ABB Emax 2 E6.2V/f air circuit breaker for demanding low-voltage power distribution.
  • 4000 A rated uninterrupted current for major industrial, commercial and infrastructure installations.
  • 150 kA Icu at 400–440 V AC for dependable interruption of exceptionally high prospective fault currents.
  • 130 kA Icu at 500–525 V AC and 100 kA Icu at 690 V AC.
  • 100 kA short-time withstand current for 1 s and 3 s supports selective protection strategies.
  • Ekip Touch LSI electronic trip unit provides long-time, short-time and instantaneous protection.
  • Four-pole full-size-neutral configuration for systems requiring a fully rated neutral pole.
  • Fixed construction with rear flat horizontal terminals for permanent switchboard integration.

Key Features

  • ABB SACE Emax 2 E6.2V/f series.
  • 4000 A rated uninterrupted current.
  • 690 V AC rated operational voltage.
  • 150 kA Icu at 400–440 V AC.
  • 130 kA Icu at 500–525 V AC.
  • 100 kA Icu at 690 V AC.
  • 100% Ics/Icu ratio.
  • 100 kA Icw for 1 s and 3 s.
  • Ekip Touch LSI solid-state electronic protection release.
  • Long-time overload protection.
  • Short-time selective short-circuit protection.
  • Instantaneous short-circuit protection.
  • 1600–4000 A overload adjustment range.
  • 2400–40000 A short-time protection adjustment range.
  • 6000–60000 A instantaneous protection adjustment range.
  • 4-pole configuration with full-size neutral.
  • Fixed circuit-breaker construction.
  • Rear flat horizontal main terminals with bolted connection.
  • Four auxiliary contacts and circuit-breaker open/closed position indication.

Advanced Selective Power Distribution Protection

The ABB Emax 2 E6.2V/f platform is designed for high-current low-voltage systems where exceptional fault-interruption capability and coordinated electronic protection are required. With a 4000 A rated uninterrupted current, breaking capacity reaching 150 kA and a 100 kA short-time withstand rating for up to three seconds, this breaker is particularly suited to critical distribution points exposed to very high prospective fault currents.

The Ekip Touch LSI electronic trip unit provides long-time overload, short-time selective and instantaneous short-circuit protection. The addition of the short-time function over an LI release enables improved time-based coordination with downstream protective devices, helping maintain selectivity and continuity of service while protecting transformers, busbars, cables and connected equipment.

Typical Applications

  • Main incomer protection in high-current low-voltage switchboards.
  • Industrial power-distribution systems.
  • Transformer secondary distribution.
  • Manufacturing and process plants.
  • Large commercial electrical installations.
  • Data centres and critical power systems.
  • Utility and infrastructure electrical distribution.
  • Four-pole systems requiring a full-size neutral and selective short-circuit protection.

Technical Specifications

Product group Emax 2 Air Circuit Breaker
Range SACE Emax 2
Series E6.2V/f
ABB order code / MPN 1SDA071965R1
EAN / GTIN 8015644758158
Product type Air circuit breaker
Rated uninterrupted current (Iu) 4000 A
Rated operational voltage (Ue) 690 V AC
Rated ultimate short-circuit breaking capacity (Icu) at 400–415 V AC 150 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 150 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500–525 V AC 130 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 100 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw) 100 kA for 1 s / 100 kA for 3 s
Number of poles 4
Neutral configuration Full-size neutral
Short-circuit performance level V
Trip unit Ekip Touch LSI
Release type Solid-state electronic
Protection functions LSI
Long-time overload protection Yes
Overload release adjustment range 1600–4000 A
Short-time selective protection Yes
Short-time protection adjustment range 2400–40000 A
Instantaneous short-circuit protection Yes
Instantaneous protection adjustment range 6000–60000 A
Integrated earth-fault protection No
Installation Fixed
Terminal position Rear
Terminal configuration Rear flat horizontal
Main circuit connection Bolted connection
Auxiliary contacts 4
Open / closed position indication Yes
Dimensions (W × H × D) 371 × 1014 × 270 mm
Net weight 151 kg
Country of origin Italy
Standard IEC 60947

Frequently Asked Questions

What is the ABB 1SDA071965R1 used for?

The ABB 1SDA071965R1 is an Emax 2 air circuit breaker designed for high-current low-voltage switching, isolation and selective circuit protection in industrial, commercial and infrastructure power-distribution systems.

What is the current rating of the ABB 1SDA071965R1?

The E6.2V/f 4000 has a rated uninterrupted current of 4000 A, making it suitable for major high-current electrical distribution systems.

What is the breaking capacity of the E6.2V/f 4000?

The breaker provides an ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC, 130 kA at 500–525 V AC and 100 kA at 690 V AC.

What protection functions does the Ekip Touch LSI provide?

The Ekip Touch LSI electronic trip unit provides adjustable long-time overload, short-time selective and instantaneous short-circuit protection. This LSI configuration does not include integrated earth-fault protection.

How is the ABB 1SDA071965R1 installed?

This model is a four-pole fixed air circuit breaker with a full-size neutral, equipped with rear flat horizontal terminals and bolted main-circuit connections for permanent integration into compatible high-current low-voltage switchboards.

Trusted High-Performance Power Protection

ABB SACE Emax 2 air circuit breakers combine high current-handling and exceptional fault-interruption capability with advanced electronic protection, helping demanding industrial and infrastructure installations achieve dependable overload and selective short-circuit protection while supporting safe, coordinated and reliable power distribution.