1SDA071955R1 ABB E6.2H/f 4000 Ekip Touch LSI 4p FHR Air Circuit Breaker

1SDA071955R1 ABB E6.2H/f 4000 Ekip Touch LSI 4p FHR Air Circuit Breaker

ABB 1SDA071955R1 E6.2H/f 4000 Ekip Touch LSI four-pole fixed full-size-neutral air circuit breaker with a 4000 A rated uninterrupted current, electronic LSI protection, rear horizontal terminals, 100 kA breaking capacity at 440 V AC and 100 kA short-time withstand current.

SKU: 1SDA071955R1MPN: 1SDA071955R1
Price
List Price £32,313.45 ex VAT
Your Price (ex VAT) Save 25%
£24,235.09 25% OFF
You save £8,078.36 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £24,235.09
Trade pricing is personalised to your account

Manufacturer Lead Time

£24,235.09

Why Choose the ABB E6.2H/f 4000 Ekip Touch LSI 4p FHR Air Circuit Breaker?

The ABB E6.2H/f 4000 Ekip Touch LSI 4p FHR, order code 1SDA071955R1, is a high-performance four-pole SACE Emax 2 air circuit breaker designed for protection and switching in demanding low-voltage power-distribution systems. This E6.2H/f full-size-neutral version combines a 4000 A rated uninterrupted current with the advanced Ekip Touch LSI electronic trip unit.

The E6.2H/f performance level provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 100 kA for 1 s. Its Ekip Touch LSI trip unit provides long-time overload, selective short-time and instantaneous short-circuit protection, allowing effective protection coordination in high-capacity electrical distribution networks.

This model is a fixed four-pole air circuit breaker with a full-size neutral and rear horizontal (FHR) terminals. The combination of a fully rated neutral path, E6.2 high-current construction and touchscreen-based LSI protection makes the 1SDA071955R1 particularly suitable for main switchboards, industrial installations, data centres and infrastructure where high neutral loading and selective short-circuit protection must be accommodated.

Key Advantages

  • High-performance ABB SACE Emax 2 E6.2H/f air circuit breaker for demanding low-voltage distribution systems.
  • 4000 A rated uninterrupted current for high-capacity incoming and distribution circuits.
  • Full-size neutral configuration for four-wire systems requiring a fully rated neutral pole.
  • 100 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 100 kA short-time withstand current for 1 s supports selective protection in high-fault-level systems.
  • Ekip Touch LSI electronic trip unit provides long-time, selective short-time and instantaneous protection.
  • Short-time protection enables improved selectivity and coordination with downstream protective devices.
  • Fixed construction with rear horizontal terminals supports integration into high-current switchboards.

Key Features

  • ABB SACE Emax 2 E6.2H/f series.
  • 4000 A rated uninterrupted current.
  • Four-pole configuration.
  • Full-size neutral.
  • Ekip Touch LSI electronic trip unit.
  • Long-time overload protection.
  • Selective short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Touchscreen interface for protection setting and supervision.
  • 100 kA Icu at 440 V AC.
  • 100 kA Icw for 1 s.
  • Fixed execution.
  • Rear horizontal (FHR) terminals.
  • E6.2 frame engineered for high-current low-voltage distribution.
  • Suitable for main incoming, busbar and high-capacity feeder protection.

Selective Full-Size-Neutral Protection for High-Current Distribution

High-current four-wire distribution systems can place substantial demands on the neutral conductor, particularly where unbalanced loads or harmonic-producing equipment are present. The ABB E6.2H/f combines a 4000 A rated uninterrupted current, full-size neutral configuration and 100 kA short-circuit performance at 440 V AC, providing a robust platform for major incoming circuits, busbars and high-capacity distribution feeders.

The Ekip Touch LSI trip unit adds selective short-time protection to the long-time and instantaneous functions, supporting more precise coordination between upstream and downstream protective devices. Its touchscreen interface simplifies configuration and supervision, making the 1SDA071955R1 well suited to installations requiring high current capacity, a fully rated neutral and advanced selective electronic protection.

Typical Applications

  • Main incoming protection in high-current four-wire low-voltage switchboards.
  • Industrial power-distribution systems.
  • Large manufacturing and process facilities.
  • Data centres and critical power infrastructure.
  • Commercial buildings with substantial neutral loading.
  • Transformer secondary and high-current feeder protection.
  • High-capacity busbar distribution systems.
  • Installations requiring a full-size neutral with selective LSI electronic protection.

Technical Specifications

Series SACE Emax 2 E6.2
Order code / MPN 1SDA071955R1
Product type Air circuit breaker (ACB)
Product group Emax 2 Air Circuit Breaker
Frame / performance level E6.2H/f
Rated uninterrupted current (Iu) 4000 A
Number of poles 4
Neutral configuration Full-size neutral
Trip unit Ekip Touch LSI
Release technology Electronic
Protection functions Long-time, short-time and instantaneous (LSI)
Earth-fault protection Not included in the LSI configuration
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated short-time withstand current (Icw), 1 s 100 kA
Execution Fixed
Main terminals Rear horizontal (FHR)
Frame size E6.2
Protection platform Ekip Touch
Application High-current low-voltage power distribution

Frequently Asked Questions

What is the ABB 1SDA071955R1 used for?

The ABB 1SDA071955R1 is an Emax 2 air circuit breaker designed for protection and switching of high-current four-wire low-voltage distribution systems, including main incoming circuits, busbars and high-capacity feeders.

What does E6.2H/f mean on the ABB 1SDA071955R1?

E6.2 identifies the Emax 2 frame, H identifies the short-circuit performance level, and the /f designation identifies the four-pole full-size-neutral configuration.

What protection does the Ekip Touch LSI trip unit provide?

The Ekip Touch LSI electronic trip unit provides long-time overload, selective short-time and instantaneous short-circuit protection. The LSI configuration does not include the earth-fault protection function provided by an LSIG release.

What is the breaking capacity of the ABB 1SDA071955R1?

The E6.2H/f 4000 has a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 100 kA for 1 s.

Is the ABB 1SDA071955R1 fixed or withdrawable?

The 1SDA071955R1 is a fixed four-pole, full-size-neutral air circuit breaker equipped with rear horizontal terminals for integration into high-current low-voltage switchboards.

Trusted Protection for High-Current Four-Wire Power Systems

ABB SACE Emax 2 air circuit breakers combine high current-carrying capability, advanced electronic protection and robust short-circuit performance, while the E6.2H/f full-size-neutral configuration supports demanding four-wire distribution systems requiring effective selectivity and dependable circuit protection.