1SDA071855R1 ABB E4.2V 4000 Ekip Touch LSI 4p FHR Air Circuit Breaker

1SDA071855R1 ABB E4.2V 4000 Ekip Touch LSI 4p FHR Air Circuit Breaker

ABB 1SDA071855R1 Emax 2 E4.2V 4000 is a 4000 A four-pole fixed air circuit breaker with Ekip Touch LSI electronic protection, 150 kA breaking capacity at 440 V AC and rear horizontal terminals for demanding low-voltage power distribution systems.

SKU: 1SDA071855R1MPN: 1SDA071855R1
Price
List Price £36,231.25 ex VAT
Your Price (ex VAT) Save 25%
£27,173.44 25% OFF
You save £9,057.81 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £27,173.44
Trade pricing is personalised to your account

Manufacturer Lead Time

£27,173.44

Why Choose the ABB E4.2V 4000 Ekip Touch LSI 4p FHR Air Circuit Breaker?

The ABB E4.2V 4000 Ekip Touch LSI 4p FHR, order code 1SDA071855R1, is a high-performance four-pole air circuit breaker (ACB) designed for protection, switching and isolation in demanding low-voltage power distribution systems. As part of the advanced ABB SACE Emax 2 series, it combines a substantial 4000 A rated current with very high short-circuit performance for critical industrial, commercial and infrastructure installations.

This Emax 2 circuit breaker incorporates the Ekip Touch LSI electronic trip unit, providing long-time overload, short-time selective short-circuit and instantaneous short-circuit protection. The addition of short-time protection supports improved selectivity and coordination between upstream and downstream protective devices, helping maintain continuity while protecting electrical equipment against damaging fault conditions.

The E4.2V 4000 is a fixed, four-pole breaker with rear horizontal terminals. The E4.2V performance level provides an ultimate short-circuit breaking capacity of 150 kA at 440 V AC and a rated short-time withstand current of 100 kA for 1 s, making it particularly suitable for high-fault-level incoming supplies, feeders and critical main distribution switchboards.

Key Advantages

  • High-capacity 4000 A air circuit breaker for demanding low-voltage distribution systems.
  • Four-pole configuration for comprehensive switching and isolation.
  • Advanced Ekip Touch LSI electronic trip unit for accurate circuit protection.
  • Long-time, short-time selective and instantaneous protection supports effective system coordination.
  • Exceptional 150 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 100 kA short-time withstand current for 1 s supports high-performance selective distribution designs.
  • Fixed installation for permanent integration into low-voltage switchboards.
  • Rear horizontal terminals facilitate connection to high-current busbar systems.

Key Features

  • ABB SACE Emax 2 E4.2V air circuit breaker.
  • 4000 A rated current.
  • Four-pole configuration.
  • Ekip Touch LSI electronic trip unit.
  • Long-time overload (L) protection.
  • Short-time selective short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • 150 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 100 kA rated short-time withstand current for 1 s.
  • Fixed construction with rear horizontal terminals.
  • Designed for high-fault-level industrial and commercial power distribution.

High-Performance Circuit Protection for Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 E4.2V provide protection, switching and isolation for high-current low-voltage electrical networks. By detecting overload and short-circuit conditions, the breaker can disconnect the affected circuit to help protect cables, switchgear and connected equipment while supporting dependable operation of the wider distribution system.

The Ekip Touch LSI trip unit combines long-time, short-time and instantaneous electronic protection, enabling selective coordination in sophisticated electrical networks. Combined with the E4.2V frame's 4000 A current rating, 150 kA breaking capacity at 440 V AC and 100 kA short-time withstand capability, the 1SDA071855R1 is well suited to critical high-power distribution applications.

Typical Applications

  • Industrial low-voltage main distribution switchboards.
  • Manufacturing plants and production facilities.
  • Commercial building electrical distribution systems.
  • Data centres and critical power infrastructure.
  • Utilities and infrastructure installations.
  • Generator and transformer distribution systems.
  • High-fault-level incoming supply protection.
  • Main and feeder circuits requiring selective short-circuit protection.

Technical Specifications

Series SACE Emax 2
Order code / Product ID 1SDA071855R1
Product type Air circuit breaker
Frame / subtype E4.2V
Performance level V
Rated current 4000 A
Number of poles 4
Current type AC
Rated operational voltage up to 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) 150 kA at 440 V AC
Rated short-time withstand current (Icw) 100 kA for 1 s
Trip unit Ekip Touch LSI
Release type Electronic
Protection functions Long-time (L), short-time (S) and instantaneous (I)
Installation version Fixed
Terminal configuration Rear horizontal
Main circuit connection Bolted
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071855R1 used for?

The ABB 1SDA071855R1 is a 4000 A four-pole air circuit breaker used for protection, switching and isolation in high-current low-voltage power distribution systems.

What protection functions does the Ekip Touch LSI trip unit provide?

The Ekip Touch LSI electronic trip unit provides long-time overload (L), short-time selective short-circuit (S) and instantaneous short-circuit (I) protection.

What is the breaking capacity of the ABB E4.2V 4000?

The E4.2V 4000 provides an ultimate short-circuit breaking capacity of 150 kA at 440 V AC.

Is the 1SDA071855R1 a fixed or withdrawable circuit breaker?

The 1SDA071855R1 is a fixed-version circuit breaker equipped with rear horizontal terminals for integration into low-voltage switchboards.

What is the short-time withstand current of the ABB E4.2V 4000?

The E4.2V 4000 has a rated short-time withstand current of 100 kA for 1 s, supporting selective protection in demanding high-fault-current distribution systems.

Trusted for High-Performance Power Distribution

ABB SACE Emax 2 air circuit breakers are designed for reliable protection, switching and management of low-voltage electrical systems, combining high-current capability with advanced electronic protection and exceptional short-circuit performance for demanding industrial, commercial and infrastructure applications.