ABB 1SDA071854R1 Emax 2 E4.2V 4000 is a 4000 A four-pole fixed air circuit breaker with Ekip Touch LI electronic protection, up to 150 kA short-circuit breaking capacity and rear horizontal terminals for demanding low-voltage power distribution systems.
£26,866.48
The ABB E4.2V 4000 Ekip Touch LI 4p FHR, order code 1SDA071854R1, is a high-performance four-pole air circuit breaker (ACB) designed for protection, switching and isolation in demanding low-voltage power distribution systems. As part of the advanced ABB SACE Emax 2 series, it combines a substantial 4000 A rated current with exceptional short-circuit performance for critical industrial, commercial and infrastructure installations.
This Emax 2 circuit breaker incorporates the Ekip Touch LI electronic trip unit, providing long-time overload and instantaneous short-circuit protection. Its electronic protection system and intuitive interface enable accurate configuration while helping protect cables, switchgear and connected equipment against damaging electrical fault conditions.
The E4.2V 4000 is a fixed, four-pole breaker with rear horizontal terminals. It is rated for operation at up to 690 V AC and provides an ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC and 100 kA at 500–690 V AC, making it particularly suitable for high-fault-level incoming supplies and critical main distribution switchboards.
Air circuit breakers such as the ABB SACE Emax 2 E4.2V provide protection, switching and isolation for high-current low-voltage electrical networks. By detecting overload and severe short-circuit conditions, the breaker can disconnect the affected circuit to help protect cables, switchgear and connected equipment while supporting safe and dependable power distribution.
The E4.2V performance level is designed for installations with particularly high prospective fault currents. Combined with the Ekip Touch LI trip unit, 4000 A current rating and breaking capacity of up to 150 kA, the 1SDA071854R1 provides a robust solution for critical incoming supplies and high-power distribution systems.
| Series | SACE Emax 2 |
|---|---|
| Order code / Product ID | 1SDA071854R1 |
| Product type | Air circuit breaker |
| Frame / subtype | E4.2V |
| Short-circuit performance level | V |
| Rated current | 4000 A |
| Rated uninterrupted current (Iu) | 4000 A |
| Number of poles | 4 |
| Neutral pole current | 100% |
| Current type | AC |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Ultimate short-circuit breaking capacity (Icu) | 150 kA at 400–440 V AC; 100 kA at 500–690 V AC |
| Service short-circuit breaking capacity (Ics) | 150 kA at 380–440 V AC; 100 kA at 500–690 V AC |
| Ics as percentage of Icu | 100% |
| Rated short-time withstand current (Icw) | 100 kA for 1 s; 75 kA for 3 s |
| Trip unit | Ekip Touch LI |
| Release type | Electronic |
| Protection functions | Long-time (L) and instantaneous (I) |
| Overload release current setting | from 1600 A |
| Instantaneous short-circuit release setting | from 6000 A |
| Integrated earth-fault protection | No |
| Installation version | Fixed |
| Terminal configuration | Rear flat horizontal |
| Main circuit connection | Bolt connection |
| Auxiliary contacts | 4 change-over contacts |
| Power loss | 465 W |
| Electrical durability | 5000 cycles at ≤440 V AC; 4000 cycles at 500–690 V AC |
| Mechanical durability | 15000 cycles |
| Protection rating | IP30 |
| Dimensions (W × H × D) | 510 × 371 × 270 mm |
| Weight | 70 kg |
| GTIN / EAN | 8015644757045 |
| Standard | IEC 60947-2 |
The ABB 1SDA071854R1 is a 4000 A four-pole air circuit breaker used for protection, switching and isolation in high-current low-voltage power distribution systems.
The Ekip Touch LI electronic trip unit provides long-time overload (L) and instantaneous short-circuit (I) protection.
The E4.2V 4000 provides an ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC and 100 kA at 500–690 V AC.
The 1SDA071854R1 is a fixed-version circuit breaker equipped with rear flat horizontal terminals for integration into low-voltage switchboards.
The breaker has a rated short-time withstand current of 100 kA for 1 s and 75 kA for 3 s, supporting demanding high-fault-current distribution applications.
ABB SACE Emax 2 air circuit breakers are designed for reliable protection, switching and management of low-voltage electrical systems, combining high-current capability with advanced electronic protection and exceptional short-circuit performance for demanding industrial, commercial and infrastructure applications.