1SDA071772R1 ABB E4.2N 3200 Ekip Dip LSI 4p F HR Air Circuit Breaker 3200 A

1SDA071772R1 ABB E4.2N 3200 Ekip Dip LSI 4p F HR Air Circuit Breaker 3200 A

ABB 1SDA071772R1 E4.2N 3200 Ekip Dip LSI 4p F HR is a 3200 A four-pole fixed SACE Emax 2 air circuit breaker with Ekip Dip LSI electronic protection, 66 kA short-circuit breaking capacity and rear horizontal terminals.

SKU: 1SDA071772R1MPN: 1SDA071772R1
Price
List Price £17,092.43 ex VAT
Your Price (ex VAT) Save 25%
£12,819.32 25% OFF
You save £4,273.11 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £12,819.32
Trade pricing is personalised to your account

Manufacturer Lead Time

£12,819.32

Why Choose the ABB E4.2N 3200 Ekip Dip LSI 4p F HR Air Circuit Breaker?

The ABB E4.2N 3200 Ekip Dip LSI 4p F HR, order code 1SDA071772R1, is a high-current four-pole air circuit breaker (ACB) from the ABB SACE Emax 2 range. Designed for fixed installation in demanding low-voltage power distribution systems, it combines a 3200 A rated uninterrupted current with an Ekip Dip LSI solid-state electronic release for long-time overload, selective short-time and instantaneous short-circuit protection.

The Ekip Dip LSI release provides configurable electronic protection using straightforward DIP-switch settings. Long-time protection is adjustable from 0.4–1 × In, selective short-circuit protection from 0.6–10 × In and instantaneous short-circuit protection from 1.5–15 × In, allowing the breaker to be coordinated with other protective devices throughout the electrical distribution system.

The E4.2N performance level provides a rated ultimate short-circuit breaking capacity of 66 kA at 380–690 V AC and a rated short-time withstand current of 66 kA for 1 s. Its four-pole fixed construction, rear horizontal terminals and four auxiliary change-over contacts make the 1SDA071772R1 a robust solution for high-current industrial, commercial and infrastructure switchboards.

Key Advantages

  • High-current ABB SACE Emax 2 air circuit breaker for demanding low-voltage distribution systems.
  • 3200 A rated uninterrupted current for substantial industrial and commercial electrical loads.
  • Four-pole configuration for simultaneous switching of three phases and neutral.
  • Ekip Dip LSI electronic trip unit with straightforward DIP-switch adjustment.
  • Provides long-time, selective short-time and instantaneous short-circuit protection.
  • 66 kA Icu at 380–690 V AC for robust short-circuit protection across common low-voltage system voltages.
  • 66 kA Icw for 1 s supports selective protection coordination in high-current distribution systems.
  • Fixed construction with rear horizontal terminals for permanent switchboard integration.
  • Four auxiliary change-over contacts support breaker status signalling and control-system integration.

Key Features

  • ABB SACE Emax 2 E4.2N series.
  • 3200 A rated uninterrupted current.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 50 / 60 Hz operating frequency.
  • Four-pole fixed air circuit breaker.
  • Ekip Dip LSI solid-state electronic release.
  • Adjustable long-time overload protection.
  • Adjustable selective short-time short-circuit protection.
  • Adjustable instantaneous short-circuit protection.
  • Long-time protection adjustment from 0.4–1 × In.
  • Short-time protection adjustment from 0.6–10 × In.
  • Instantaneous protection adjustment from 1.5–15 × In.
  • 66 kA Icu at 380–690 V AC.
  • 66 kA Icw for 1 s.
  • Rear horizontal main terminals with bolted main-circuit connection.
  • Four auxiliary change-over contacts.
  • Open/closed circuit-breaker position indication.
  • Optional motor-drive capability.

Selective High-Current Protection for Power Distribution

ABB SACE Emax 2 air circuit breakers provide switching, isolation and protection for high-current low-voltage distribution circuits. With its 3200 A rated uninterrupted current, 66 kA ultimate short-circuit breaking capacity and 66 kA short-time withstand capability for 1 s, the E4.2N 3200 is designed for substantial incoming supplies and distribution feeders where reliable fault interruption is essential.

The Ekip Dip LSI release combines long-time overload protection with selective short-time and instantaneous short-circuit protection. Its DIP-switch configuration provides a straightforward method of setting protection thresholds, while short-time protection enables coordinated distribution-system designs that can help isolate downstream faults without unnecessarily interrupting unaffected circuits.

Typical Applications

  • Low-voltage main distribution switchboards.
  • High-current incoming supply circuits.
  • Industrial electrical distribution systems.
  • Manufacturing and process plants.
  • Large commercial building power distribution.
  • Transformer secondary protection.
  • High-current outgoing distribution feeders.
  • Infrastructure and utility installations.
  • Power distribution systems requiring selective short-circuit coordination.

Technical Specifications

Series SACE Emax 2
ABB product group Emax2 Air Circuit Breaker
Frame / type E4.2N
Order code 1SDA071772R1
EAN / GTIN 8015644756222
Product type Air circuit breaker
Rated uninterrupted current (Iu) 3200 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50 / 60 Hz
Number of poles 4
Release Ekip Dip LSI
Release type Solid-state electronic
Protection functions Long-time, short-time and instantaneous (LSI)
Long-time overload protection setting 0.4–1 × In
Long-time overload adjustment 1280–3200 A
Selective short-circuit protection setting 0.6–10 × In
Instantaneous short-circuit protection setting 1.5–15 × In
Instantaneous protection adjustment 4800–48000 A
Integrated earth-fault protection No
Protection adjustment method DIP switches
Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 400–415 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500–525 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Rated short-time withstand current (Icw) 66 kA for 1 s
Short-circuit performance level N
Version Fixed (F)
Terminal connection Rear horizontal (HR)
Main-circuit connection Bolt connection
Main-circuit connection position Rear
Auxiliary contacts 4 change-over contacts
Position indication Circuit breaker open / closed
Control element Push button
Motor drive Optional
Degree of protection IP30
Power loss 425 W
Dimensions (W × H × D) 510 × 371 × 270 mm
Net weight 70 kg
Country of origin Italy
Reference standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071772R1 used for?

The ABB 1SDA071772R1 is a 3200 A four-pole air circuit breaker designed for switching and protecting high-current low-voltage distribution circuits where configurable LSI protection and selective short-circuit coordination are required.

What is the current rating of the E4.2N 3200 Ekip Dip LSI?

The breaker has a rated uninterrupted current of 3200 A and a rated operational voltage of up to 690 V AC.

What protection does the Ekip Dip LSI release provide?

The Ekip Dip LSI solid-state electronic release provides long-time overload, selective short-time short-circuit and instantaneous short-circuit protection, with protection settings configured using DIP switches.

What is the breaking capacity of the ABB E4.2N 3200?

The E4.2N 3200 provides a rated ultimate short-circuit breaking capacity of 66 kA at 380–690 V AC and a rated short-time withstand current of 66 kA for 1 s.

Is the ABB 1SDA071772R1 fixed or withdrawable?

The 1SDA071772R1 is a fixed four-pole air circuit breaker with rear horizontal terminals and bolted main-circuit connections for permanent installation within a low-voltage switchboard.

Trusted High-Current Power Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high-current switching, configurable electronic protection and strong short-time withstand performance to provide dependable selective protection for demanding low-voltage electrical distribution systems.