1SDA071640R1 ABB E2.2S 1600 Ekip G Hi-Touch LSIG 4-Pole Fixed Air Circuit Breaker

1SDA071640R1 ABB E2.2S 1600 Ekip G Hi-Touch LSIG 4-Pole Fixed Air Circuit Breaker

ABB 1SDA071640R1 Emax 2 E2.2S 1600 is a 1600 A four-pole fixed air circuit breaker with rear horizontal terminals and an Ekip G Hi-Touch LSIG electronic trip unit for advanced generator, overload, short-circuit and ground-fault protection.

SKU: 1SDA071640R1MPN: 1SDA071640R1
Price
List Price £14,091.00 ex VAT
Your Price (ex VAT) Save 25%
£10,568.25 25% OFF
You save £3,522.75 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £10,568.25
Trade pricing is personalised to your account

Manufacturer Lead Time

£10,568.25

Why Choose the ABB E2.2S 1600 Ekip G Hi-Touch LSIG 4p FHR Air Circuit Breaker?

The ABB E2.2S 1600 Ekip G Hi-Touch LSIG 4p FHR, order code 1SDA071640R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) engineered for generator protection and demanding low-voltage power distribution systems. This fixed four-pole E2.2S breaker combines a 1600 A rated current with ABB's advanced Ekip G Hi-Touch LSIG solid-state electronic trip unit and rear horizontal main terminals.

The Ekip G Hi-Touch LSIG release provides long-time overload, short-time selective short-circuit, instantaneous short-circuit and ground-fault protection, together with protection functions specifically developed for generator applications. Integrated Ekip Measuring Pro and Network Analyzer functionality adds advanced electrical measurement and power-quality analysis, supporting detailed supervision of critical generation and distribution systems.

The E2.2S performance level provides an ultimate short-circuit breaking capacity of 85 kA at 380–440 V AC and 66 kA at 500–690 V AC. With a rated operational voltage of 690 V AC, fixed four-pole construction and rear horizontal connections, the 1SDA071640R1 is well suited to generator switchboards, standby power systems, main incomers and critical industrial distribution networks.

Key Advantages

  • 1600 A rated current for high-current generator and power-distribution circuits.
  • Ekip G Hi-Touch LSIG release combines comprehensive circuit protection with generator-specific protection functions.
  • Long-time, short-time, instantaneous and ground-fault functions provide comprehensive electronic protection.
  • 85 kA Icu at 380–440 V AC provides substantial short-circuit interruption capability.
  • 66 kA Icu at 500–690 V AC supports demanding higher-voltage low-voltage networks.
  • Ekip Measuring Pro provides integrated advanced electrical measurement.
  • Integrated Network Analyzer supports power-quality monitoring and analysis.
  • Touch-sensitive display provides an intuitive interface for configuration and operating information.
  • Fixed four-pole construction with rear horizontal terminals supports straightforward switchboard integration.

Key Features

  • ABB SACE Emax 2 E2.2S frame.
  • 1600 A rated current.
  • Four-pole fixed air circuit breaker.
  • Ekip G Hi-Touch LSIG solid-state electronic release.
  • Long-time overload protection (L).
  • Short-time selective short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Ground-fault protection (G).
  • Dedicated generator protection functionality.
  • Overload protection adjustable from 0.4–1 × In.
  • Instantaneous protection adjustable from 1.5–15 × In.
  • Ground-fault protection adjustable from 0.1–1 × In.
  • Integrated Ekip Measuring Pro functionality.
  • Integrated Network Analyzer functionality.
  • Touch-sensitive electronic configuration interface.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 50 / 60 Hz rated frequency.
  • 85 kA Icu at 380–440 V AC.
  • 66 kA Icu at 500–690 V AC.
  • 66 kA rated short-time withstand current for 1 s.
  • Rear horizontal main terminals.
  • Four auxiliary contacts with circuit-breaker open/closed position indication.
  • Designed in accordance with IEC 60947-2.

Advanced Generator and Power-Distribution Protection

The ABB SACE Emax 2 E2.2S combines substantial short-circuit interruption capability with advanced electronic protection designed for critical low-voltage systems. The Ekip G Hi-Touch release is specifically equipped for generator applications, where the electrical behaviour and fault-current characteristics of generating sets require sophisticated protection and supervision.

LSIG functionality provides protection against sustained overloads, selective short circuits, severe instantaneous faults and ground faults. Ekip Measuring Pro and Network Analyzer functionality additionally provide detailed electrical measurement and power-quality information, making the 1SDA071640R1 a comprehensive protection and monitoring solution for generator-fed and critical distribution systems.

Typical Applications

  • Generator protection and generator switchboards.
  • Standby and emergency power-generation systems.
  • Main low-voltage switchboards and distribution assemblies.
  • Industrial main incomers and high-current feeders.
  • Transformer and generator-fed distribution networks.
  • Manufacturing and process facilities.
  • Data centres and critical power infrastructure.
  • Networks requiring advanced measurement, ground-fault protection and power-quality supervision.

Technical Specifications

Series SACE Emax 2
Frame E2.2S
ABB order code 1SDA071640R1
EAN 8015644754907
Product type Air circuit breaker
Current type AC
Rated current 1600 A
Number of poles 4
Trip unit Ekip G Hi-Touch LSIG
Release type Solid-state electronic
Protection functions Long-time (L), short-time (S), instantaneous (I) and ground-fault (G)
Application Generator and power-distribution protection
Overload protection adjustment 0.4–1 × In
Instantaneous protection adjustment 1.5–15 × In
Ground-fault protection adjustment 0.1–1 × In
Measurement Ekip Measuring Pro
Power-quality analysis Integrated Network Analyzer
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated frequency 50 / 60 Hz
Icu at 380 / 400 / 415 / 440 V AC 85 kA
Icu at 500 / 525 / 690 V AC 66 kA
Rated short-time withstand current (Icw), 1 s 66 kA
Installation Fixed
Terminal position Rear
Terminal orientation Horizontal
Auxiliary contacts 4
Breaker position indication Open / closed
Product width 366 mm
Product height 371 mm
Product depth 270 mm
Net weight 53 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB E2.2S 1600 Ekip G Hi-Touch LSIG 4p FHR used for?

It is a 1600 A four-pole fixed air circuit breaker designed for advanced generator and low-voltage power-distribution protection, making it suitable for generator switchboards, critical power systems and industrial distribution networks.

What protection functions does the Ekip G Hi-Touch LSIG trip unit provide?

The Ekip G Hi-Touch LSIG electronic release provides long-time overload, short-time selective short-circuit, instantaneous short-circuit and ground-fault protection, together with generator-specific protection functionality.

What is the breaking capacity of ABB 1SDA071640R1?

The E2.2S 1600 provides an ultimate short-circuit breaking capacity of 85 kA at 380–440 V AC and 66 kA at 500–690 V AC.

What monitoring capabilities does the Ekip G Hi-Touch release provide?

The release incorporates Ekip Measuring Pro for advanced electrical measurement and an integrated Network Analyzer for power-quality monitoring and analysis.

Is ABB 1SDA071640R1 fixed or withdrawable?

This configuration is a fixed four-pole air circuit breaker equipped with rear horizontal terminals for integration into low-voltage switchgear.

Advanced Generator Protection from ABB SACE Emax 2

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, advanced electronic protection, electrical measurement and generator-focused functionality to support dependable operation of critical low-voltage power systems.