1SDA071629R1 ABB E2.2N 1600 Ekip Hi-Touch LSIG 4-Pole Fixed Air Circuit Breaker

1SDA071629R1 ABB E2.2N 1600 Ekip Hi-Touch LSIG 4-Pole Fixed Air Circuit Breaker

ABB 1SDA071629R1 Emax 2 E2.2N 1600 is a 1600 A four-pole fixed air circuit breaker with rear flat horizontal terminals and an Ekip Hi-Touch LSIG electronic trip unit for advanced overload, short-circuit and ground-fault protection.

SKU: 1SDA071629R1MPN: 1SDA071629R1
Price
List Price £12,785.22 ex VAT
Your Price (ex VAT) Save 25%
£9,588.92 25% OFF
You save £3,196.31 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,588.92
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,588.92

Why Choose the ABB E2.2N 1600 Ekip Hi-Touch LSIG 4p FHR Air Circuit Breaker?

The ABB E2.2N 1600 Ekip Hi-Touch LSIG 4p FHR, order code 1SDA071629R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for advanced protection and switching in demanding low-voltage AC power distribution systems. This fixed four-pole E2.2N configuration combines a 1600 A rated current with ABB's Ekip Hi-Touch LSIG solid-state electronic trip unit and rear flat horizontal main terminals.

The Ekip Hi-Touch LSIG release provides long-time overload, short-time selective short-circuit, instantaneous short-circuit and ground-fault protection. The Hi-Touch platform adds advanced measurement and monitoring capabilities, making this breaker particularly suitable for critical electrical systems where comprehensive protection, selectivity and detailed supervision of the distribution network are required.

The E2.2N performance level provides an ultimate short-circuit breaking capacity of 66 kA from 400–690 V AC, with a rated short-time withstand current of 66 kA for 1 s. Rated for operation up to 690 V AC, the 1SDA071629R1 combines substantial fault interruption performance with fixed construction, four-pole switching and rear horizontal connections for integration into main switchboards and high-current distribution assemblies.

Key Advantages

  • 1600 A rated current for high-current low-voltage distribution systems.
  • Four-pole configuration for three-phase networks incorporating the neutral conductor.
  • Ekip Hi-Touch LSIG electronic trip unit provides comprehensive overload, short-circuit and ground-fault protection.
  • Short-time protection supports selective coordination with downstream protective devices.
  • Ground-fault protection provides an additional layer of protection against earth-fault conditions.
  • 66 kA Icu from 400–690 V AC provides substantial fault interruption capability across a broad voltage range.
  • 66 kA Icw for 1 s supports demanding selective power-distribution designs.
  • Advanced Hi-Touch functionality supports sophisticated measurement, monitoring and power-management requirements.
  • Fixed construction with rear flat horizontal terminals for switchboard integration.

Key Features

  • ABB SACE Emax 2 E2.2N frame.
  • 1600 A rated uninterrupted current.
  • Four-pole fixed air circuit breaker.
  • Ekip Hi-Touch LSIG solid-state electronic release.
  • Long-time overload protection (L).
  • Short-time selective short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Ground-fault protection (G).
  • Advanced electronic measurement and monitoring functionality.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 66 kA Icu at 400, 415, 440, 500, 525 and 690 V AC.
  • 66 kA Icw for 1 s and 50 kA for 3 s.
  • Rear flat horizontal main terminals with bolted connection.
  • Four auxiliary contacts.
  • Circuit-breaker open/closed position indication.
  • 100% Ics/Icu service breaking capacity.
  • Designed for advanced protection of high-current low-voltage distribution systems.

Advanced Protection for Critical Power Distribution

The ABB SACE Emax 2 E2.2N is engineered for switching and protection at critical points within high-current low-voltage networks. Its 1600 A current capability, 66 kA breaking capacity and strong short-time withstand performance make this configuration suitable for main distribution circuits where fault interruption, selectivity and continuity of service are important design considerations.

The Ekip Hi-Touch LSIG release combines four complementary protection functions. Long-time protection responds to sustained overloads, short-time protection enables selective coordination, instantaneous protection provides rapid interruption of severe short circuits, and ground-fault protection responds to potentially damaging earth-fault currents. Together with the advanced capabilities of the Hi-Touch platform, this provides a comprehensive protection solution for sophisticated power-distribution systems.

Typical Applications

  • Main low-voltage switchboards and power-distribution assemblies.
  • Industrial main incomer protection.
  • High-current feeder circuits.
  • Transformer secondary distribution systems.
  • Manufacturing and process facilities.
  • Data centres and critical power infrastructure.
  • Commercial and large-building electrical distribution.
  • Networks requiring selective short-circuit and ground-fault protection.

Technical Specifications

Series SACE Emax 2
Frame E2.2N
ABB order code 1SDA071629R1
EAN 8015644754792
Product type Air circuit breaker
Current type AC
Rated current (In) 1600 A
Rated uninterrupted current (Iu) 1600 A
Number of poles 4
Trip unit Ekip Hi-Touch LSIG
Release type Solid-state electronic
Protection functions Long-time (L), short-time (S), instantaneous (I) and ground-fault (G)
Short-circuit performance level N
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Icu at 400 / 415 / 440 V AC 66 kA
Icu at 500 / 525 / 690 V AC 66 kA
Rated service breaking capacity (Ics) 100% of Icu
Ics at 220–690 V AC 66 kA
Rated short-time withstand current (Icw), 1 s 66 kA
Rated short-time withstand current (Icw), 3 s 50 kA
Installation Fixed
Terminal connection Rear flat horizontal
Terminal type Bolt
Auxiliary contacts 4
Breaker position indication Open / closed
Power loss 136 W
Dimensions (H × W × D) 366 × 371 × 270 mm
Net weight 53 kg
Standard IEC

Frequently Asked Questions

What is the ABB E2.2N 1600 Ekip Hi-Touch LSIG 4p FHR used for?

It is a 1600 A four-pole fixed air circuit breaker designed for advanced protection and switching of high-current low-voltage distribution circuits in industrial, commercial and infrastructure installations.

What protection functions does the Ekip Hi-Touch LSIG trip unit provide?

The Ekip Hi-Touch LSIG electronic release provides long-time overload, short-time selective short-circuit, instantaneous short-circuit and ground-fault protection.

What is the breaking capacity of ABB 1SDA071629R1?

The E2.2N 1600 has an ultimate short-circuit breaking capacity of 66 kA at 400–690 V AC, together with a rated short-time withstand current of 66 kA for 1 s.

What is the difference between Ekip Hi-Touch LSI and Ekip Hi-Touch LSIG?

Both provide long-time, short-time and instantaneous circuit protection, while Ekip Hi-Touch LSIG additionally provides ground-fault protection for enhanced protection against current flowing to earth.

Is ABB 1SDA071629R1 fixed or withdrawable?

This configuration is a fixed four-pole air circuit breaker equipped with rear flat horizontal terminals for integration into low-voltage switchgear.

Advanced Power Protection from ABB SACE Emax 2

ABB SACE Emax 2 air circuit breakers combine high-current switching capability, selective electronic protection and advanced monitoring functionality to support dependable protection and management of modern low-voltage power distribution systems.