ABB 1SDA071582R1 Emax 2 E2.2N 1250 A four-pole fixed air circuit breaker with rear flat horizontal terminals, Ekip Dip LSI electronic protection and 66 kA breaking capacity across 380–690 V AC for selective low-voltage power distribution protection.
£5,993.08
The ABB E2.2N 1250 Ekip Dip LSI 4p FHR, order code 1SDA071582R1, is a high-performance four-pole air circuit breaker (ACB) designed for protection and switching in demanding low-voltage power distribution systems. Part of the ABB SACE Emax 2 series, it combines a 1250 A rated current with electronic LSI protection and robust short-circuit performance for industrial, commercial and infrastructure installations.
The breaker is equipped with the Ekip Dip LSI electronic trip unit, providing long-time overload, short-time selective short-circuit and instantaneous short-circuit protection. Protection settings are configured using DIP switches, providing a practical and reliable method of adapting the breaker to the requirements of the electrical installation while supporting selective coordination between protective devices.
With a rated operational voltage of 690 V AC and an ultimate short-circuit breaking capacity of 66 kA across 380–690 V AC, the 1SDA071582R1 provides dependable fault interruption across a broad range of low-voltage distribution applications. Its fixed four-pole construction with rear flat horizontal terminals is designed for permanent integration into switchboards and busbar assemblies.
Air circuit breakers such as the ABB SACE Emax 2 provide essential switching and protection for high-current low-voltage electrical systems. By detecting abnormal current conditions and interrupting the circuit when configured thresholds are exceeded, the breaker helps protect cables, busbars, switchgear and connected equipment against damaging overload and short-circuit faults.
The Ekip Dip LSI release combines long-time overload, short-time selective and instantaneous short-circuit protection. The short-time protection stage provides greater flexibility when coordinating multiple protective devices, helping downstream protection clear localised faults before an upstream breaker operates where the installation and protection settings are designed for selective operation.
| Product group | Emax2 Air Circuit Breaker |
|---|---|
| Series | SACE Emax 2 E2.2N |
| ABB order code | 1SDA071582R1 |
| EAN | 8015644754327 |
| Product type | Air circuit breaker |
| Rated current (In) | 1250 A |
| Rated uninterrupted current (Iu) | 1250 A |
| Number of poles | 4 |
| Neutral pole current | 100% |
| Trip unit | Ekip Dip LSI electronic release |
| Protection functions | L (long-time overload), S (short-time short circuit) and I (instantaneous short circuit) |
| Overload protection adjustment | 0.4–1 × In |
| Overload protection adjustment range | 500–1250 A |
| Short-time protection | Adjustable |
| Instantaneous protection adjustment | 1.5–15 × In |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Frequency | 50 / 60 Hz |
| Ultimate breaking capacity (Icu) at 380 V AC | 66 kA |
| Ultimate breaking capacity (Icu) at 400 / 415 V AC | 66 kA |
| Ultimate breaking capacity (Icu) at 440 V AC | 66 kA |
| Ultimate breaking capacity (Icu) at 500 / 525 V AC | 66 kA |
| Ultimate breaking capacity (Icu) at 690 V AC | 66 kA |
| Service breaking capacity (Ics) | 100% of Icu |
| Rated short-time withstand current (Icw) | 66 kA for 1 s; 50 kA for 3 s |
| Installation | Fixed |
| Terminal arrangement | Rear flat horizontal |
| Main circuit connection | Bolt connection |
| Connecting capacity | 1200 mm² |
| Terminal tightening torque | 70 N·m |
| Auxiliary contacts | 4 |
| Power loss | 83 W |
| Electrical durability | 15,000 operating cycles |
| Mechanical durability | 25,000 operating cycles |
| Suitable for IT networks | Yes, up to 690 V |
| Standard | IEC 60947-2 |
The ABB 1SDA071582R1 is a four-pole air circuit breaker designed for switching and protection in high-current low-voltage power distribution systems, including industrial, commercial and infrastructure switchboards.
The ABB E2.2N 1250 has a rated uninterrupted current of 1250 A, with long-time overload protection adjustable from 500–1250 A.
The Ekip Dip LSI electronic trip unit provides long-time overload, short-time selective short-circuit and instantaneous short-circuit protection, with settings configured through DIP switches.
The E2.2N has an ultimate short-circuit breaking capacity of 66 kA across 380–690 V AC, with a rated service breaking capacity equal to 100% of Icu.
The FHR configuration identifies this Emax 2 breaker as a fixed version with rear flat horizontal terminals, designed for permanent integration into compatible low-voltage switchboards and busbar systems.
ABB SACE Emax 2 air circuit breakers combine configurable electronic protection with robust short-circuit performance and durable construction, providing dependable switching and protection for demanding low-voltage electrical distribution systems.