1SDA071535R1 ABB Emax 2 E2.2S 800A Ekip Touch LSI 4P FHR Air Circuit Breaker

1SDA071535R1 ABB Emax 2 E2.2S 800A Ekip Touch LSI 4P FHR Air Circuit Breaker

ABB 1SDA071535R1 is a SACE Emax 2 E2.2S 800 A fixed four-pole air circuit breaker with rear horizontal terminals, an Ekip Touch LSI electronic trip unit, 690 V AC rated operational voltage, 85 kA breaking capacity at 380–440 V AC and 66 kA short-time withstand current for 1 s.

SKU: 1SDA071535R1MPN: 1SDA071535R1
Price
List Price £8,419.53 ex VAT
Your Price (ex VAT) Save 25%
£6,314.65 25% OFF
You save £2,104.88 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,314.65
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,314.65

Why Choose the ABB 1SDA071535R1 Emax 2 Air Circuit Breaker?

The ABB 1SDA071535R1 is a high-performance SACE Emax 2 E2.2S air circuit breaker (ACB) designed for advanced protection and control of demanding low-voltage electrical distribution systems. Rated at 800 A, this fixed four-pole circuit breaker combines ABB’s E2.2S frame with the Ekip Touch LSI solid-state electronic trip unit for configurable long-time overload, short-time delayed and instantaneous short-circuit protection.

As part of the ABB SACE Emax 2 series, the E2.2S combines high short-circuit performance with sophisticated electronic protection and an intuitive touchscreen interface. The Ekip Touch LSI release adds selective short-time protection to the standard long-time and instantaneous functions, making this configuration particularly suitable for installations where protection coordination and selectivity between upstream and downstream devices are important.

With a rated uninterrupted current of 800 A, rated operational voltage of 690 V AC, rated ultimate short-circuit breaking capacity of 85 kA at 380–440 V AC and rated short-time withstand current of 66 kA for 1 s, the 1SDA071535R1 provides substantial fault-handling capability. This version features a fixed four-pole configuration with rear horizontal terminals, making it well suited to high-performance switchboards with rear busbar connections.

Key Advantages

  • High-performance 800 A air circuit breaker for demanding low-voltage power distribution.
  • 85 kA ultimate short-circuit breaking capacity at 380–440 V AC.
  • 66 kA rated short-time withstand current for 1 s supports demanding selectivity and protection coordination requirements.
  • Advanced Ekip Touch LSI electronic trip unit provides long-time, short-time and instantaneous protection.
  • Adjustable short-time protection helps coordinate the breaker with downstream protective devices.
  • Touch-sensitive interface simplifies protection configuration, commissioning and operation.
  • Four-pole fixed configuration with rear horizontal terminals supports efficient busbar integration.
  • ABB Emax 2 architecture provides a flexible platform for modern low-voltage distribution systems.

Key Features

  • ABB SACE Emax 2 E2.2S air circuit breaker.
  • 800 A rated uninterrupted current.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 85 kA Icu at 380–440 V AC.
  • 66 kA Icu at 500–690 V AC.
  • 66 kA Icw for 1 s.
  • Ekip Touch LSI solid-state electronic release.
  • Long-time overload, selective short-time delayed and instantaneous short-circuit protection.
  • Adjustable long-time overload protection from 320–800 A.
  • Adjustable short-time protection from 480–8000 A.
  • Adjustable instantaneous protection from 1200–12,000 A.
  • Touch-sensitive display for intuitive electronic protection configuration.
  • Fixed four-pole construction.
  • Rear horizontal terminals for main circuit connections.
  • Supplied with four auxiliary contacts.
  • Open/closed circuit-breaker position indication.
  • Designed in accordance with IEC 60947-2.

Advanced Selective Protection for Low-Voltage Distribution

Air circuit breakers such as the ABB SACE Emax 2 E2.2S protect important low-voltage distribution circuits against damaging overload and short-circuit conditions. The 1SDA071535R1 combines an 800 A continuous-current rating with 85 kA ultimate short-circuit breaking capability at 380–440 V AC and 66 kA short-time withstand capability for 1 s, providing the performance required for demanding main and distribution circuits.

The Ekip Touch LSI trip unit adds selective short-time delayed protection to long-time overload and instantaneous short-circuit functions. This allows more sophisticated coordination with downstream protective devices, while the touchscreen interface provides convenient access to protection settings and operating information. Combined with rear horizontal terminals, the breaker is well suited to switchboards requiring both high fault capability and practical rear busbar connectivity.

Typical Applications

  • Main incoming protection for low-voltage switchboards.
  • Industrial electrical distribution systems.
  • Commercial building power distribution.
  • Transformer secondary protection.
  • Manufacturing and process facilities.
  • Distribution feeders requiring selective short-circuit protection.
  • Data centres and critical-power installations.
  • Low-voltage switchgear with rear busbar connections.

Technical Specifications

Series SACE Emax 2
Frame / sub-type E2.2S
Order code / MPN 1SDA071535R1
EAN / GTIN 8015644753856
Product type Air circuit breaker
Short-circuit performance level S
Rated current (In) 800 A
Rated uninterrupted current (Iu) 800 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50 / 60 Hz
Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 400–415 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500–525 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Rated short-time withstand current (Icw) for 1 s 66 kA
Number of poles 4
Trip unit Ekip Touch LSI
Release type Solid-state electronic
Protection functions LSI
Overload protection adjustment 0.4–1 × In
Overload protection adjustment range 320–800 A
Short-time protection adjustment 0.6–10 × In
Short-time protection adjustment range 480–8000 A
Instantaneous protection adjustment 1.5–15 × In
Instantaneous protection adjustment range 1200–12,000 A
Long-time overload protection Yes
Short-time delayed short-circuit protection Yes
Instantaneous short-circuit protection Yes
Integrated ground-fault protection No
User interface Touch-sensitive display
Current type AC
Installation version Fixed
Terminal configuration Rear horizontal
Main circuit connection Bolted connection
Auxiliary contacts 4
Circuit-breaker position indication Open / closed
Product net weight 53 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071535R1 used for?

The ABB 1SDA071535R1 is an 800 A Emax 2 air circuit breaker designed to protect and control demanding low-voltage electrical distribution circuits in industrial, commercial and infrastructure switchboards.

What is the current rating of the ABB 1SDA071535R1?

The ABB 1SDA071535R1 has a rated uninterrupted current of 800 A and a rated operational voltage of 690 V AC.

What breaking capacity does the E2.2S 800 provide?

The E2.2S 800 provides a rated ultimate short-circuit breaking capacity of 85 kA at 380–440 V AC and 66 kA at 500–690 V AC, with a rated short-time withstand current of 66 kA for 1 s.

What protection does the Ekip Touch LSI trip unit provide?

The Ekip Touch LSI solid-state electronic trip unit provides configurable long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. This LSI configuration does not include integrated ground-fault protection.

What terminal configuration does the ABB 1SDA071535R1 use?

The 1SDA071535R1 is a fixed four-pole air circuit breaker with rear horizontal terminals, providing a practical connection arrangement for busbars within low-voltage switchboard assemblies.

Trusted High-Performance Circuit Protection

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, high short-circuit performance, selective protection capability and flexible installation configurations for dependable operation in modern industrial, commercial and critical-power low-voltage distribution systems.