Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA071507R1 is a SACE Emax 2 E1.2C 1600 A fixed four-pole air circuit breaker with front terminals, an Ekip G Touch LSIG electronic trip unit, generator-oriented protection, 690 V AC rated operational voltage and 50 kA breaking capacity at 400 V AC.
£8,456.50
The ABB 1SDA071507R1 is a high-performance SACE Emax 2 E1.2C air circuit breaker (ACB) designed for advanced protection, monitoring and control of low-voltage generator and electrical distribution systems. Rated at 1600 A, this fixed four-pole circuit breaker combines ABB’s compact E1.2 frame with the Ekip G Touch LSIG electronic trip unit for comprehensive overload, short-circuit, ground-fault and generator-specific protection.
As part of the ABB SACE Emax 2 series, the E1.2C is engineered to provide high short-circuit performance and effective selectivity within compact switchboard installations. The Ekip G Touch LSIG release provides long-time, short-time, instantaneous and ground-fault protection together with functions developed for generator applications, while its large colour touchscreen supports intuitive configuration and operation.
With a rated uninterrupted current of 1600 A, rated operational voltage of 690 V AC and rated ultimate short-circuit breaking capacity of 50 kA at 400 V AC, the 1SDA071507R1 provides robust fault protection for demanding low-voltage installations. This version features a fixed four-pole configuration with front terminals, making it particularly suitable for generator switchboards, industrial power distribution and critical-power applications.
Air circuit breakers such as the ABB SACE Emax 2 E1.2C protect critical low-voltage circuits against damaging overload, short-circuit and ground-fault conditions. The 1SDA071507R1 combines a 1600 A continuous-current rating with 50 kA ultimate short-circuit breaking capability at 400 V AC, providing robust protection for high-current generator and distribution systems.
The Ekip G Touch LSIG trip unit extends conventional LSIG protection with functionality developed for generator applications. Its colour touchscreen and Ekip Connect compatibility simplify configuration and commissioning, while the Emax 2 platform supports communication modules for integration with automation, energy-management and intelligent low-voltage distribution systems.
| Series | SACE Emax 2 |
|---|---|
| Frame / sub-type | E1.2C |
| Order code / MPN | 1SDA071507R1 |
| EAN / GTIN | 8015644753573 |
| Product type | Air circuit breaker |
| Short-circuit performance level | C |
| Rated current (In) | 1600 A |
| Rated uninterrupted current (Iu) | 1600 A |
| Rated operational voltage | 690 V AC |
| Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC, 50 Hz | 50 kA |
| Number of poles | 4 |
| Trip unit | Ekip G Touch LSIG |
| Release type | Solid-state electronic |
| Protection functions | LSIG plus generator-oriented protection |
| Overload protection adjustment range | 640–1600 A |
| Short-time delayed short-circuit adjustment range | 960–16,000 A |
| Instantaneous short-circuit adjustment range | 2400–24,000 A |
| Long-time overload protection | Yes |
| Short-time delayed short-circuit protection | Yes |
| Instantaneous short-circuit protection | Yes |
| Integrated ground-fault protection | Yes |
| User interface | Colour touchscreen |
| Configuration | ABB Ekip Connect compatible |
| Current type | AC |
| Installation version | Fixed |
| Terminal configuration | Front terminals |
| Main circuit connection | Bolt connection |
| Auxiliary contacts | 4 change-over contacts |
| Trip indication | Yes |
| Integrated undervoltage release | No |
| Integrated motor drive | No |
| Optional motor drive | Yes |
| Degree of protection | IP30 |
| Power loss | 201 W |
| Width | 280 mm |
| Depth | 183 mm |
| Country of origin | Italy |
| Standard / approval | IEC |
The ABB 1SDA071507R1 is a 1600 A Emax 2 air circuit breaker designed for advanced protection and control of low-voltage generator and electrical distribution circuits in industrial, commercial and critical-power switchboards.
The circuit breaker has a rated uninterrupted current of 1600 A and a rated operational voltage of 690 V AC.
The ABB E1.2C 1600 in this configuration has a rated ultimate short-circuit breaking capacity of 50 kA at 400 V AC, 50 Hz.
The Ekip G Touch LSIG electronic trip unit provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and ground-fault protection together with generator-oriented protection functionality.
The 1SDA071507R1 is a fixed four-pole air circuit breaker with front terminals for integration into generator and low-voltage distribution switchboards.
ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, generator-oriented functionality, high short-circuit performance and flexible system integration for dependable operation in modern industrial, commercial and critical-power electrical systems.
We use cookies