1SDA071475R1 ABB E1.2N 1250 Ekip Touch LSI 4-Pole Air Circuit Breaker

1SDA071475R1 ABB E1.2N 1250 Ekip Touch LSI 4-Pole Air Circuit Breaker

ABB 1SDA071475R1 is a SACE Emax 2 E1.2N 1250 A fixed four-pole air circuit breaker with front terminals and an Ekip Touch LSI solid-state electronic trip unit providing configurable overload, selective short-circuit and instantaneous protection for low-voltage power distribution systems.

SKU: 1SDA071475R1MPN: 1SDA071475R1
Price
List Price £7,884.71 ex VAT
Your Price (ex VAT) Save 25%
£5,913.53 25% OFF
You save £1,971.18 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,913.53
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,913.53

Why Choose the ABB 1SDA071475R1 E1.2N 1250 Ekip Touch LSI Air Circuit Breaker?

The ABB 1SDA071475R1 is a SACE Emax 2 E1.2N air circuit breaker designed for reliable protection and switching in demanding low-voltage power distribution systems. Rated at 1250 A, this four-pole fixed breaker combines ABB's compact E1.2N frame with the advanced Ekip Touch LSI solid-state electronic trip unit.

The Ekip Touch LSI release provides long-time overload (L), short-time selective short-circuit (S) and instantaneous short-circuit (I) protection. Adjustable protection settings and the touch-sensitive interface support straightforward configuration, while the short-time function enables selective coordination with suitable downstream protective devices.

The 1SDA071475R1 is supplied in a fixed four-pole configuration with front terminals and is fitted with four auxiliary change-over contacts plus open/closed breaker position indication. With a rated operational voltage of 690 V AC and an ultimate short-circuit breaking capacity of 66 kA at 380–440 V AC, it provides robust protection for industrial, commercial and infrastructure power distribution applications.

Key Advantages

  • 1250 A SACE Emax 2 air circuit breaker for substantial low-voltage distribution circuits.
  • Compact E1.2N frame combines space-efficient construction with high short-circuit performance.
  • Advanced Ekip Touch LSI electronic trip unit.
  • Long-time, short-time and instantaneous protection functions.
  • Short-time protection supports selective coordination within electrical distribution networks.
  • 66 kA ultimate short-circuit breaking capacity at 380–440 V AC.
  • 50 kA service short-circuit breaking capacity across the specified operating-voltage range.
  • Four-pole fixed construction with front terminals for permanent switchboard installation.

Key Features

  • ABB SACE Emax 2 E1.2N series.
  • 1250 A rated current.
  • 4-pole fixed configuration.
  • Front terminal connections.
  • Ekip Touch LSI solid-state electronic release.
  • Long-time overload protection (L).
  • Short-time selective short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Long-time protection adjustable from 0.4–1 × In.
  • Short-time protection adjustable from 0.6–10 × In.
  • Instantaneous protection adjustable from 1.5–15 × In.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 66 kA Icu at 380–440 V AC.
  • Touch-sensitive interface for protection configuration.

Selective LSI Protection for Low-Voltage Power Distribution

The ABB SACE Emax 2 E1.2N platform provides switching, isolation and electronic fault protection for low-voltage electrical distribution networks. Its compact construction, 1250 A current rating and substantial short-circuit capability make the 1SDA071475R1 suitable for switchboards where dependable protection, selective coordination and efficient use of installation space are important.

The Ekip Touch LSI release protects against sustained overloads, delayed short circuits and severe instantaneous short circuits. Adjustable LSI protection enables coordinated tripping strategies to be implemented across appropriately designed distribution networks, while the touch-sensitive interface simplifies configuration and supervision of the electronic protection functions.

Typical Applications

  • Low-voltage switchboard incomer protection.
  • Industrial power distribution systems.
  • Commercial building electrical distribution.
  • Transformer secondary distribution systems.
  • Feeder and distribution circuit protection.
  • Manufacturing and process facilities.
  • Infrastructure and critical electrical installations.
  • Distribution systems requiring selective short-circuit protection.

Technical Specifications

Series SACE Emax 2
Frame E1.2N
ABB order code 1SDA071475R1
EAN 8015644753252
Product type Air circuit breaker
Rated current (In) 1250 A
Number of poles 4
Neutral pole current 100% of Iu
Installation Fixed
Main terminal arrangement Front terminals
Main circuit connection Bolt connection
Trip unit Ekip Touch LSI
Release type Solid-state electronic
Protection functions Long-time (L), short-time (S), instantaneous (I)
Long-time overload protection adjustment 0.4–1 × In
Short-time selective protection adjustment 0.6–10 × In
Instantaneous protection adjustment 1.5–15 × In
Integrated earth-fault protection No
Current type AC
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Frequency 50 / 60 Hz
Ultimate short-circuit breaking capacity (Icu) at 380 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 400/415 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 500/525 V AC 50 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 50 kA
Rated service short-circuit breaking capacity (Ics) 50 kA
Ics as percentage of Icu 100%
Electrical durability at ≤440 V AC 8000 cycles
Electrical durability at 500–690 V AC 6500 cycles
Mechanical durability 20000 cycles
Power loss 122 W
Connecting capacity 1000 mm²
Auxiliary contacts 4 change-over contacts
Breaker position indication Open / closed
Product net width 284 mm
Product net height 295 mm
Product net depth 184 mm
Product net weight 11 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071475R1?

The ABB 1SDA071475R1 is a SACE Emax 2 E1.2N 1250 A four-pole fixed air circuit breaker with front terminals and an Ekip Touch LSI solid-state electronic protection release.

What protection functions does the Ekip Touch LSI trip unit provide?

The Ekip Touch LSI release provides long-time overload protection (L), short-time selective short-circuit protection (S) and instantaneous short-circuit protection (I).

What is the breaking capacity of the ABB E1.2N 1250?

The E1.2N 1250 provides an ultimate short-circuit breaking capacity of 66 kA at 380–440 V AC and 50 kA at 500–690 V AC.

What is the rated current of the ABB 1SDA071475R1?

The circuit breaker has a rated current of 1250 A, making it suitable for substantial low-voltage incomer, feeder and distribution applications.

Does the ABB 1SDA071475R1 include earth-fault protection?

No. This model uses an LSI trip configuration providing long-time, short-time and instantaneous protection; an LSIG version is required where integrated G earth-fault protection is specified.

What is the advantage of Ekip Touch LSI protection?

Ekip Touch LSI combines configurable overload, delayed short-circuit and instantaneous short-circuit protection with a touch-sensitive interface, supporting selective coordination and convenient protection configuration.

Is the ABB 1SDA071475R1 fixed or withdrawable?

This model is a fixed four-pole air circuit breaker with front terminals, designed for permanent installation within a suitable low-voltage switchboard or power distribution assembly.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers combine compact construction, configurable electronic protection and robust short-circuit performance for industrial, commercial and infrastructure low-voltage power distribution systems.