ABB 1SDA071423R1 Emax 2 E1.2C 1000 Ekip Dip LSIG four-pole fixed air circuit breaker with front terminals, a 1000 A rated current, earth-fault protection and 50 kA ultimate short-circuit breaking capacity at 400/415 V AC.
£5,522.31
The ABB E1.2C 1000 Ekip Dip LSIG 4p F F, order code 1SDA071423R1, is a compact four-pole air circuit breaker (ACB) designed for comprehensive protection of low-voltage power distribution systems. Part of the ABB SACE Emax 2 series, this fixed circuit breaker combines a 1000 A rated current, robust short-circuit performance and an Ekip Dip LSIG electronic protection release.
The integrated Ekip Dip LSIG electronic trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection. Adjustable protection settings allow the breaker to be coordinated with other protective devices, supporting selective fault isolation while providing dedicated protection against earth-fault conditions.
With a rated operational voltage of 690 V AC, rated insulation voltage of 1000 V AC and an ultimate short-circuit breaking capacity of 50 kA at 400/415 V AC, the E1.2C 1000 provides dependable protection in a compact Emax 2 frame. This version features a four-pole fixed configuration with front terminals for integration into three-phase four-wire switchboards and power distribution assemblies.
Air circuit breakers such as the ABB Emax 2 E1.2C provide switching and protection for low-voltage electrical distribution systems. By detecting overload, short-circuit and earth-fault conditions and interrupting fault current, the breaker helps protect switchboards, cables, busbars and connected electrical equipment while supporting dependable operation of the wider electrical installation.
The Ekip Dip LSIG release combines adjustable long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection. Short-time protection supports selective coordination between protective devices, while the integrated earth-fault function provides additional protection against faults involving earth, making this configuration well suited to distribution systems requiring comprehensive electronic protection.
| Series | SACE Emax 2 |
|---|---|
| Order code / MPN | 1SDA071423R1 |
| EAN | 8015644752736 |
| Product type | Air circuit breaker |
| Frame / sub-type | E1.2 |
| Performance level | C |
| Rated current (In) | 1000 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Frequency | 50 / 60 Hz |
| Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC | 50 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 400/415 V AC | 50 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 50 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 42 kA |
| Rated short-time withstand current (Icw) for 1 s | 42 kA |
| Number of poles | 4P |
| Neutral pole current | 100% Iu |
| Current type | AC |
| Trip unit | Ekip Dip LSIG electronic release |
| Protection functions | Long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) |
| Overload protection adjustment | 0.4–1 × In |
| Short-time short-circuit protection adjustment | 0.6–10 × In |
| Instantaneous protection adjustment | 1.5–15 × In |
| Earth-fault protection adjustment | 0.1–1 × In |
| Protection setting method | DIP switches |
| Integrated earth-fault protection | Yes |
| Mounting type | Fixed |
| Terminal type | Front terminals |
| Main circuit connection | Bolt connection |
| Auxiliary changeover contacts | 4 |
| Motor operator | Optional |
| Degree of protection | IP30 |
| Power loss | 78 W |
| Mechanical durability | 20,000 cycles |
| Electrical durability | 8,000 cycles at up to 440 V AC; 8,000 cycles at 500–690 V AC |
| Dimensions | 280 mm width × 296 mm height × 183 mm depth |
| Net weight | 16 kg |
| Standard | IEC 60947-2 |
The ABB 1SDA071423R1 is a four-pole air circuit breaker designed for switching and protecting low-voltage electrical distribution systems against overload, short-circuit and earth-fault conditions.
This Emax 2 air circuit breaker has a rated current of 1000 A and a rated operational voltage of 690 V AC.
The E1.2C 1000 has an ultimate short-circuit breaking capacity of 50 kA at 400/415 V AC and 42 kA at 690 V AC, with a rated short-time withstand current of 42 kA for 1 s.
The Ekip Dip LSIG electronic release provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection, with adjustable settings configured using DIP switches.
The 1SDA071423R1 is a fixed four-pole air circuit breaker with front main circuit terminals for integration into low-voltage switchboards.
ABB SACE Emax 2 air circuit breakers combine compact construction, dependable interruption performance and configurable electronic protection for industrial, commercial and infrastructure low-voltage power distribution systems.