1SDA071347R1 ABB E1.2C 630 Ekip G Touch LSIG 4p F F Air Circuit Breaker

1SDA071347R1 ABB E1.2C 630 Ekip G Touch LSIG 4p F F Air Circuit Breaker

ABB 1SDA071347R1 SACE Emax 2 E1.2C 630 four-pole fixed air circuit breaker with front terminals, Ekip G Touch LSIG protection, 630 A rated current and 50 kA ultimate breaking capacity at 400 V AC.

SKU: 1SDA071347R1MPN: 1SDA071347R1
Price
List Price £9,850.90 ex VAT
Your Price (ex VAT) Save 25%
£7,388.18 25% OFF
You save £2,462.73 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,388.18
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,388.18

Why Choose the ABB E1.2C 630 Ekip G Touch LSIG 4p F F Air Circuit Breaker?

The ABB E1.2C 630 Ekip G Touch LSIG 4p F F, order code 1SDA071347R1, is a compact SACE Emax 2 air circuit breaker (ACB) designed for protection and management of low-voltage power distribution and generator circuits. This fixed four-pole E1.2C breaker combines a 630 A rated uninterrupted current with ABB's advanced Ekip G Touch LSIG electronic trip unit.

The Ekip G Touch LSIG trip unit provides long-time, short-time, instantaneous and ground-fault protection, helping protect electrical systems against overloads, short circuits and earth faults. The Ekip G Touch platform adds generator-oriented protection and monitoring capabilities, making this configuration particularly suitable for generator switchboards, standby power systems and critical distribution networks.

The E1.2C performance level provides an ultimate short-circuit breaking capacity of 50 kA at 400 V AC. Rated for operation at 690 V AC, this breaker uses a fixed four-pole construction with front terminals and is supplied with four auxiliary change-over contacts for open/closed circuit-breaker status indication.

Key Advantages

  • Compact 630 A SACE Emax 2 air circuit breaker for demanding low-voltage systems.
  • Ekip G Touch LSIG electronic trip unit with generator-oriented protection and monitoring functionality.
  • Long-time, short-time, instantaneous and ground-fault protection.
  • 50 kA ultimate short-circuit breaking capacity at 400 V AC.
  • Four-pole configuration for distribution systems requiring switching of all four conductors.
  • Fixed construction with front terminals for straightforward switchboard integration.
  • Four auxiliary change-over contacts provide breaker status information for control and monitoring systems.

Key Features

  • ABB SACE Emax 2 E1.2C series.
  • 630 A rated uninterrupted current (Iu).
  • 4-pole configuration.
  • Fixed circuit breaker construction.
  • Front terminals.
  • Ekip G Touch LSIG electronic trip unit.
  • Long-time (L) overload protection.
  • Short-time (S) delayed short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Ground-fault (G) protection.
  • 252–630 A overload release adjustment range.
  • 378–6300 A short-time delayed short-circuit adjustment range.
  • 945–9450 A instantaneous short-circuit adjustment range.
  • 50 kA ultimate short-circuit breaking capacity at 400 V AC.
  • Integrated earth-fault protection.
  • Optional motor drive for electrically operated switching applications.

Advanced Generator and Distribution Protection

The ABB SACE Emax 2 E1.2C combines switching, isolation and electronic protection in a compact air circuit breaker platform. Its 630 A rated current, four-pole configuration and 50 kA short-circuit breaking capacity at 400 V AC make it suitable for generator switchboards, incoming feeders and other important positions within low-voltage power distribution systems.

The Ekip G Touch LSIG release provides dedicated long-time, short-time, instantaneous and ground-fault protection together with generator-oriented functionality. Adjustable overload and short-circuit thresholds support coordinated protection, helping isolate electrical faults while maintaining continuity of supply to unaffected parts of the installation.

Typical Applications

  • Generator protection and generator switchboards.
  • Standby and emergency power systems.
  • Low-voltage electrical distribution switchboards.
  • Industrial power distribution systems.
  • Main and sub-main incoming feeders.
  • Four-pole distribution circuits requiring neutral switching.
  • Commercial and infrastructure electrical systems.
  • Critical installations requiring comprehensive LSIG protection.

Technical Specifications

Series SACE Emax 2
Frame E1.2C
ABB order code 1SDA071347R1
Product type Air circuit breaker
Rated uninterrupted current (Iu) 630 A
Rated voltage 690 V AC
Number of poles 4
Short-circuit performance level C
Trip unit Ekip G Touch LSIG
Release type Solid-state electronic release
Protection functions L, S, I and G
Overload release adjustment 252–630 A
Short-time delayed short-circuit adjustment 378–6300 A
Instantaneous short-circuit adjustment 945–9450 A
Ultimate short-circuit breaking capacity (Icu) at 400 V AC, 50 Hz 50 kA
Integrated earth-fault protection Yes
Execution Fixed
Terminal arrangement Front terminals
Auxiliary contacts 4 change-over contacts
Circuit-breaker open/closed indication Yes
Motor drive integrated No
Motor drive Optional
EAN 8015644751975
ABB product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA071347R1?

The ABB 1SDA071347R1 is a SACE Emax 2 E1.2C 630 Ekip G Touch LSIG four-pole fixed air circuit breaker with front terminals, designed for low-voltage power distribution and generator protection applications.

What is the rated current of the ABB E1.2C 630?

The breaker has a rated uninterrupted current of 630 A and an adjustable long-time overload protection range of 252–630 A.

What protection does the Ekip G Touch LSIG trip unit provide?

The Ekip G Touch LSIG electronic trip unit provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection, together with functionality designed for generator and power-distribution applications.

What is the breaking capacity of ABB 1SDA071347R1?

The E1.2C 630 has an ultimate short-circuit breaking capacity of 50 kA at 400 V AC, 50 Hz.

Where is the ABB E1.2C 630 Ekip G Touch LSIG typically used?

It is typically used in generator switchboards, standby power systems, low-voltage distribution boards, industrial electrical systems and four-pole feeder applications requiring comprehensive LSIG protection.

Advanced Protection for Generator and Distribution Systems

ABB SACE Emax 2 air circuit breakers combine compact construction, advanced electronic protection and flexible system integration, providing dependable switching and protection for generator installations and critical low-voltage power distribution networks.