ABB 1SDA071237R1 is a SACE Emax 2 E6.2H 4000 A fixed three-pole air circuit breaker with rear horizontal terminals, an Ekip G Touch LSIG electronic trip unit, 100 kA ultimate short-circuit breaking capacity at 440 V AC and 100 kA one-second short-time withstand capability.
£17,496.84
The ABB E6.2H 4000 Ekip G Touch LSIG 3p FHR, order code 1SDA071237R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for advanced protection, switching and control in demanding low-voltage generator and power distribution systems. Rated at 4000 A, this three-pole fixed circuit breaker combines ABB's E6.2H frame with the advanced Ekip G Touch LSIG electronic trip unit.
The Ekip G Touch LSIG release provides comprehensive long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection. The generator-oriented Ekip G platform is designed for applications requiring sophisticated protection and supervision, making this breaker particularly suitable for generator switchboards, critical power systems and high-current distribution networks.
This configuration is a fixed three-pole breaker with rear horizontal (HR) terminals. The E6.2H 4000 provides an ultimate short-circuit breaking capacity of 100 kA at 440 V AC together with a rated short-time withstand current of 100 kA for 1 s, delivering substantial fault-handling capability for demanding power-generation and distribution installations.
Air circuit breakers such as the ABB SACE Emax 2 provide switching, isolation and fault protection for major low-voltage electrical circuits. The E6.2H frame combines a substantial 4000 A current rating with 100 kA ultimate breaking capacity at 440 V AC and 100 kA one-second short-time withstand capability, making it suitable for installations with significant prospective fault currents.
The Ekip G Touch LSIG trip unit combines long-time, short-time and instantaneous overcurrent protection with integrated earth-fault protection and generator-oriented functionality. This comprehensive protection architecture supports selective coordination and effective fault management in generator and critical power systems, helping correctly engineered installations isolate faults while maintaining continuity of supply to unaffected circuits.
| Series | SACE Emax 2 |
|---|---|
| Frame | E6.2H |
| ABB order code | 1SDA071237R1 |
| Product type | Air circuit breaker |
| Rated uninterrupted current (Iu) | 4000 A |
| Number of poles | 3 |
| Trip unit | Ekip G Touch LSIG |
| Release type | Electronic |
| Protection functions | L, S, I and G |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 100 kA |
| Rated short-time withstand current (Icw, 1 s) | 100 kA |
| Short-circuit performance level | H |
| Integrated earth-fault protection | Yes |
| Generator-oriented protection | Yes |
| Installation | Fixed |
| Terminal configuration | Rear horizontal (HR) |
| Product net weight | 109 kg |
| Product group | Emax2 Air Circuit Breaker |
The ABB 1SDA071237R1 is a SACE Emax 2 E6.2H fixed three-pole air circuit breaker rated at 4000 A and equipped with an Ekip G Touch LSIG electronic trip unit.
The Ekip G Touch LSIG release provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection together with functionality for generator and critical power applications.
The circuit breaker has a rated uninterrupted current of 4000 A.
The E6.2H 4000 configuration has an ultimate short-circuit breaking capacity of 100 kA at 440 V AC.
The E6.2H 4000 has a rated short-time withstand current of 100 kA for 1 s, supporting demanding high-current and selectively coordinated distribution systems.
Yes. The G function within the Ekip G Touch LSIG release provides integrated earth-fault protection in addition to long-time, short-time and instantaneous overcurrent protection.
Yes. The Ekip G Touch release is intended for generator-oriented protection applications, making this configuration suitable for generator switchboards, power-generation systems and critical power distribution networks.
This configuration is a fixed circuit breaker with rear horizontal terminals, providing rear-facing main connections suitable for integration with switchboard busbars and power conductors.
ABB SACE Emax 2 air circuit breakers combine high-current switching and protection with advanced electronic trip technology, generator-oriented protection and sophisticated power-management capabilities for demanding industrial, infrastructure, critical power and power-generation applications worldwide.