1SDA071198R1 ABB E4.2N 4000 Ekip Hi-Touch LSI 3p FHR Air Circuit Breaker

1SDA071198R1 ABB E4.2N 4000 Ekip Hi-Touch LSI 3p FHR Air Circuit Breaker

ABB 1SDA071198R1 Emax 2 E4.2N 4000 Ekip Hi-Touch LSI three-pole fixed air circuit breaker with a 4000 A rated uninterrupted current, 690 V AC operational voltage, 66 kA breaking capacity and advanced LSI electronic protection for high-current low-voltage power distribution systems.

SKU: 1SDA071198R1MPN: 1SDA071198R1
Price
List Price £22,997.80 ex VAT
Your Price (ex VAT) Save 25%
£17,248.35 25% OFF
You save £5,749.45 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £17,248.35
Trade pricing is personalised to your account

Manufacturer Lead Time

£17,248.35

Why Choose the ABB E4.2N 4000 Ekip Hi-Touch LSI 3p FHR Air Circuit Breaker?

The ABB E4.2N 4000 Ekip Hi-Touch LSI 3p FHR, order code 1SDA071198R1, is a high-current air circuit breaker (ACB) designed for advanced protection, switching and isolation in low-voltage power distribution systems. Part of the ABB Emax 2 air circuit breaker series, it combines a 4000 A rated uninterrupted current with the advanced Ekip Hi-Touch LSI electronic trip unit for industrial, commercial, infrastructure and critical-power installations.

The E4.2N performance level provides a rated ultimate short-circuit breaking capacity of 66 kA at 400–690 V AC. Its Ekip Hi-Touch LSI electronic release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection, supporting accurate protection settings and selective coordination across complex electrical distribution networks.

With a rated operational voltage of 690 V AC, three-pole construction and fixed installation with rear flat horizontal terminals, the 1SDA071198R1 is engineered for integration into high-capacity low-voltage switchboards and distribution assemblies. A rated short-time withstand current of 66 kA for 1 s further supports selective protection strategies where continuity of supply and dependable fault protection are important.

Key Advantages

  • High-current ABB Emax 2 E4.2N air circuit breaker for demanding low-voltage distribution systems.
  • 4000 A rated uninterrupted current for large electrical loads and high-capacity switchboards.
  • 66 kA Icu across 400–690 V AC provides consistent short-circuit interruption capability.
  • Advanced Ekip Hi-Touch LSI electronic trip unit with long-time, short-time and instantaneous protection.
  • 66 kA short-time withstand current for 1 s supports selective protection coordination.
  • Ics equal to 100% of Icu across the specified operating voltage range.
  • Three-pole fixed configuration with rear flat horizontal terminals for high-capacity switchboard installations.

Key Features

  • ABB Emax 2 E4.2N series.
  • 4000 A rated uninterrupted current (Iu).
  • 690 V AC rated operational voltage.
  • 66 kA ultimate short-circuit breaking capacity (Icu) at 400–690 V AC.
  • 66 kA service short-circuit breaking capacity (Ics) at 400–690 V AC.
  • 66 kA rated short-time withstand current (Icw) for 1 s.
  • 50 kA rated short-time withstand current (Icw) for 3 s.
  • Ekip Hi-Touch LSI electronic protection release.
  • Long-time overload, selective short-time and instantaneous short-circuit protection.
  • Three-pole fixed-mounted construction.
  • Rear flat horizontal main terminals.
  • Bolted main-circuit connections.
  • Four auxiliary contacts for breaker status signalling.
  • Suitable for IT networks up to 690 V.
  • Designed for transformer, generator and installation protection applications.

Advanced Selective Protection for High-Current Distribution

Air circuit breakers such as the ABB Emax 2 E4.2N provide switching, isolation and overcurrent protection for high-current low-voltage distribution systems. The E4.2N combines a substantial 4000 A current rating with 66 kA short-circuit breaking capability, helping protect switchboards, busbars, transformers, cables and downstream electrical equipment against severe electrical faults.

The Ekip Hi-Touch LSI electronic trip unit combines long-time overload, selective short-time and instantaneous short-circuit protection. The short-time protection function enables coordination between upstream and downstream protective devices, helping localise faults while maintaining continuity of supply to unaffected sections of the electrical installation.

Typical Applications

  • Main incomer protection in high-capacity low-voltage switchboards.
  • Industrial power distribution systems.
  • Transformer and generator protection.
  • Data centres and critical-power installations.
  • Commercial and infrastructure electrical distribution.
  • Manufacturing facilities and process plants.
  • High-current feeder protection.
  • Low-voltage switchgear and selectively coordinated distribution assemblies.

Technical Specifications

Product group Emax 2 Air Circuit Breaker
Series SACE Emax 2 E4.2
Performance level N
Order code / SKU 1SDA071198R1
Product type Air circuit breaker (ACB)
Rated uninterrupted current (Iu) 4000 A
Rated operational voltage (Ue) 690 V AC
Number of poles 3
Trip unit Ekip Hi-Touch LSI
Release type Electronic (EL)
Protection functions Long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I)
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 525 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw), 1 s 66 kA
Rated short-time withstand current (Icw), 3 s 50 kA
Installation Fixed
Main terminal position Rear
Terminal configuration Rear flat horizontal
Terminal type Bolt
Auxiliary contacts 4
Open/closed position indication Yes
Suitable for IT networks Yes, up to 690 V
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071198R1 used for?

The ABB 1SDA071198R1 is an Emax 2 air circuit breaker designed for switching, isolation and advanced overcurrent protection in high-current low-voltage distribution systems, including transformer, generator and installation protection applications.

What is the current rating of the ABB E4.2N 4000?

The breaker has a rated uninterrupted current of 4000 A, making it suitable for high-capacity switchboards, main incomers and large power distribution systems.

What is the breaking capacity of the ABB 1SDA071198R1?

The E4.2N provides a rated ultimate short-circuit breaking capacity of 66 kA at 400–690 V AC. Its service short-circuit breaking capacity is 100% of Icu, and its rated short-time withstand current is 66 kA for 1 s.

What protection functions does the Ekip Hi-Touch LSI trip unit provide?

The Ekip Hi-Touch LSI electronic trip unit provides long-time overload, selective short-time short-circuit and instantaneous short-circuit protection, supporting sophisticated protection coordination in low-voltage distribution systems.

Is the ABB 1SDA071198R1 fixed or withdrawable?

The 1SDA071198R1 is a fixed three-pole air circuit breaker with rear flat horizontal main terminals and bolted connections for integration into low-voltage switchboards and power distribution assemblies.

Trusted Power Protection from ABB

ABB Emax 2 air circuit breakers are engineered for advanced protection and control of high-current low-voltage electrical distribution systems, combining robust short-circuit performance with intelligent Ekip electronic protection technology.