ABB 1SDA071157R1 E4.2S 3200 Ekip G Touch LSIG 3p F HR is a fixed three-pole 3200 A SACE Emax 2 air circuit breaker with 85 kA breaking capacity at 415 V AC, generator-oriented Ekip G Touch LSIG electronic protection and integrated earth-fault protection.
£14,558.78
The ABB E4.2S 3200 Ekip G Touch LSIG 3p F HR, order code 1SDA071157R1, is a high-performance air circuit breaker (ACB) designed for generator protection and demanding low-voltage power distribution systems. Part of the ABB SACE Emax 2 series, this fixed three-pole circuit breaker combines a 3200 A rated uninterrupted current with the Ekip G Touch LSIG electronic trip unit.
The Ekip G Touch LSIG release provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection, together with functionality intended for generator applications. Its electronic interface supports configurable protection and monitoring, helping engineers coordinate protection across generation and distribution systems while maintaining effective fault discrimination.
The E4.2S performance level provides an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC, together with a short-time withstand current of 66 kA for 1 s. This version features a fixed three-pole construction with rear flat horizontal terminals and four auxiliary contacts for integration with control and signalling systems.
Generator circuits can require specialised protection because fault behaviour and operating conditions differ from conventional utility-fed distribution systems. The ABB E4.2S 3200 with Ekip G Touch combines high-current switching capability with generator-oriented electronic protection, making it suitable for generator switchboards, standby power systems and industrial generation installations.
The Ekip G Touch LSIG release combines long-time overload, short-time delayed, instantaneous short-circuit and earth-fault protection with configurable electronic functionality for generator applications. Together with the E4.2S frame's 3200 A current capability and high short-circuit performance, this supports selective coordination, reliable fault isolation and protection of generators, conductors, switchgear and connected equipment.
| Series | SACE Emax 2 |
|---|---|
| ABB product group | Emax2 Air Circuit Breaker |
| Frame | E4.2S |
| ABB order code / MPN | 1SDA071157R1 |
| Product type | Air circuit breaker |
| Rated current (In) | 3200 A |
| Rated uninterrupted current (Iu) | 3200 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Ultimate short-circuit breaking capacity (Icu) | 85 kA at 400–440 V AC; 66 kA at 500–690 V AC |
| Service short-circuit breaking capacity (Ics) | 85 kA at 380–440 V AC; 66 kA at 500–690 V AC |
| Ics relative to Icu | 100% |
| Short-time withstand current (Icw) | 66 kA for 1 s; 66 kA for 3 s |
| Number of poles | 3 |
| Current type | AC |
| Trip unit | Ekip G Touch LSIG |
| Release type | Electronic |
| Protection functions | LSIG with generator-oriented protection functionality |
| Overload release adjustment range | 1280–3200 A |
| Short-time delayed short-circuit adjustment range | 1920–32000 A |
| Earth-fault protection | Integrated |
| Short-circuit performance level | S |
| Installation version | Fixed |
| Main terminal orientation | Rear flat horizontal |
| Connecting capacity | 3000 mm² |
| Auxiliary contacts | 4 |
| Open/closed position indication | Yes |
| Suitable for IT networks | Yes, up to 690 V |
| Mechanical durability | 20,000 cycles |
| Electrical durability | 7,000 cycles at Ue ≤ 440 V; 7,000 cycles at Ue 500–690 V |
| Power loss | 425 W |
| Dimensions (W × H × D) | 384 × 371 × 270 mm |
| Net weight | 56 kg |
| Standard | IEC |
| Country of origin | Italy |
| EAN / GTIN | 8015644750077 |
The ABB 1SDA071157R1 is an Emax 2 air circuit breaker designed for high-current low-voltage power distribution and generator protection applications, combining a 3200 A E4.2S breaker with the Ekip G Touch LSIG electronic trip unit.
The circuit breaker has a rated uninterrupted current of 3200 A, making it suitable for substantial generator circuits and high-current low-voltage power distribution systems.
The E4.2S 3200 provides an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC.
The Ekip G Touch LSIG trip unit provides long-time overload (L), short-time delayed short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection together with functionality intended for generator applications.
The 1SDA071157R1 is a fixed three-pole air circuit breaker equipped with rear flat horizontal terminals for integration into low-voltage switchboards and generator protection assemblies.
ABB SACE Emax 2 air circuit breakers are designed for reliable protection, control and monitoring of low-voltage power distribution systems, combining high short-circuit performance with advanced electronic protection for demanding industrial, commercial and generator applications.