1SDA071154R1 ABB E4.2S 3200 Ekip Touch LI 3p F HR Air Circuit Breaker

1SDA071154R1 ABB E4.2S 3200 Ekip Touch LI 3p F HR Air Circuit Breaker

ABB 1SDA071154R1 E4.2S 3200 Ekip Touch LI is a fixed three-pole 3200 A SACE Emax 2 air circuit breaker with rear horizontal terminals, 85 kA breaking capacity at 400 V AC and electronic long-time and instantaneous protection.

SKU: 1SDA071154R1MPN: 1SDA071154R1
Price
List Price £15,123.98 ex VAT
Your Price (ex VAT) Save 25%
£11,342.99 25% OFF
You save £3,781.00 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £11,342.99
Trade pricing is personalised to your account

Manufacturer Lead Time

£11,342.99

Why Choose the ABB E4.2S 3200 Ekip Touch LI 3p F HR Air Circuit Breaker?

The ABB E4.2S 3200 Ekip Touch LI 3p F HR, order code 1SDA071154R1, is a high-performance 3200 A three-pole air circuit breaker (ACB) designed for switching, isolation and protection in demanding low-voltage power distribution systems. Part of the ABB SACE Emax 2 series, it combines the E4.2S performance class with fixed mounting, rear horizontal terminals and an advanced Ekip Touch LI electronic trip unit.

The E4.2S platform provides an ultimate short-circuit breaking capacity of 85 kA at 400 V AC, while the breaker is rated for operation up to 690 V AC. This combination of high continuous-current capacity and substantial fault interruption performance makes it suitable for main distribution circuits in industrial, commercial and infrastructure installations.

Protection is provided by the Ekip Touch LI solid-state electronic release, delivering long-time overload and instantaneous short-circuit protection. The 1SDA071154R1 is supplied as a fixed three-pole breaker with rear flat horizontal terminals and is fitted with four auxiliary change-over contacts plus open/closed breaker position indication.

Key Advantages

  • Advanced ABB SACE Emax 2 air circuit breaker for high-current power distribution.
  • 3200 A rated uninterrupted current for demanding electrical installations.
  • Ekip Touch LI electronic trip unit for configurable overload and instantaneous short-circuit protection.
  • 85 kA ultimate short-circuit breaking capacity at 400 V AC.
  • Rated for low-voltage AC systems up to 690 V AC.
  • Fixed three-pole construction for permanent switchboard installation.
  • Rear flat horizontal terminals for integration into power distribution assemblies.

Key Features

  • ABB SACE Emax 2 E4.2S series.
  • 3200 A rated uninterrupted current.
  • Three-pole configuration.
  • Fixed mounting design.
  • Rear flat horizontal main terminals.
  • Ekip Touch LI solid-state electronic release.
  • Long-time overload protection.
  • Instantaneous short-circuit protection.
  • 85 kA Icu at 400 V AC.
  • Rated operational voltage of 690 V AC.
  • Four auxiliary change-over contacts.
  • Open/closed circuit-breaker position indication.
  • Optional motor operating mechanism.
  • IP30 degree of protection.

Advanced High-Current Low-Voltage Protection

ABB SACE Emax 2 air circuit breakers provide switching, isolation and protection for high-current low-voltage electrical networks. The E4.2S 3200 platform combines a 3200 A current rating with an 85 kA breaking capacity at 400 V AC, providing dependable performance for substantial industrial and commercial distribution systems.

The Ekip Touch LI electronic release provides long-time protection against sustained overload conditions together with instantaneous protection against severe short-circuit currents. Its electronic interface supports accurate protection configuration, while the Emax 2 platform is designed for integration into modern automation and energy-management systems.

Typical Applications

  • Main low-voltage distribution switchboards.
  • High-current industrial power distribution systems.
  • Manufacturing and process plants.
  • Large commercial building electrical systems.
  • Transformer-fed distribution networks.
  • Infrastructure and utility installations.
  • High-current switchgear and power distribution assemblies.

Technical Specifications

Series SACE Emax 2
Order code 1SDA071154R1
EAN 8015644750046
Product type Air circuit breaker (ACB)
Rated uninterrupted current (Iu) 3200 A
Rated operational voltage 690 V AC
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 85 kA
Number of poles 3
Current type AC
Mounting Fixed
Main terminal arrangement Rear flat horizontal
Main circuit connection Bolt connection
Trip unit Ekip Touch LI
Release type Electronic
Protection functions Long-time and instantaneous
Integrated earth-fault protection No
Auxiliary contacts 4 change-over contacts
Breaker position indication Open / closed
Integrated motor operator No
Optional motor operator Yes
Degree of protection IP30
Power loss 425 W
Dimensions 384 × 371 × 270 mm
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA071154R1 used for?

The ABB 1SDA071154R1 is a 3200 A air circuit breaker designed for switching, isolation and protection of high-current low-voltage power distribution circuits.

What protection unit is fitted to the ABB 1SDA071154R1?

The breaker is fitted with an ABB Ekip Touch LI electronic trip unit, providing long-time overload and instantaneous short-circuit protection.

What is the rated current of the ABB E4.2S 1SDA071154R1?

The breaker has a rated uninterrupted current of 3200 A.

Is the ABB 1SDA071154R1 fixed or withdrawable?

The 1SDA071154R1 is a fixed three-pole air circuit breaker equipped with rear flat horizontal main terminals.

What is the breaking capacity of the ABB E4.2S 3200?

The E4.2S 3200 has an ultimate short-circuit breaking capacity of 85 kA at 400 V AC, providing high fault-current interruption capability for demanding low-voltage distribution systems.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, robust construction and high short-circuit performance for dependable switching and protection in modern industrial, commercial and infrastructure low-voltage power distribution systems.