ABB 1SDA071040R1 Emax 2 E2.2N 2000 fixed three-pole air circuit breaker with Ekip G Hi-Touch LSIG electronic protection, 2000 A rated current and 66 kA breaking capacity at 400 V AC.
£10,334.39
The ABB E2.2N 2000 Ekip G Hi-Touch LSIG 3p FHR, order code 1SDA071040R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for advanced protection and control of low-voltage AC power distribution and generator systems. Part of the ABB Emax 2 E2.2 series, this fixed three-pole breaker combines a 2000 A rated current with the advanced Ekip G Hi-Touch electronic trip unit.
The Ekip G Hi-Touch LSIG release provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection, together with functions developed for sophisticated power and generator applications. Its electronic protection architecture helps engineers achieve dependable fault discrimination, equipment protection and system supervision in demanding electrical installations.
With a rated operational voltage of up to 690 V AC and an ultimate short-circuit breaking capacity of 66 kA at 400 V AC, the E2.2N 2000 provides robust protection for high-current distribution systems. This model has a fixed three-pole construction with rear horizontal terminals, making it particularly suitable for integration into low-voltage switchboards and power distribution assemblies.
Air circuit breakers such as the ABB SACE Emax 2 provide switching and protection at critical points within low-voltage distribution networks. The E2.2N 2000 combines a high continuous-current capability with 66 kA short-circuit interruption performance, allowing it to protect high-current feeders, incomers and other essential distribution circuits.
The Ekip G Hi-Touch LSIG electronic release combines sophisticated protection technology with functionality suited to generator and advanced power-system applications. Its LSIG protection functions provide comprehensive response to overload, delayed and instantaneous short circuits and earth faults, helping maintain system selectivity and protect valuable electrical equipment.
| Series | SACE Emax 2 E2.2 |
|---|---|
| ABB order code | 1SDA071040R1 |
| Product type | Air circuit breaker |
| Performance level | N |
| Rated current (In) | 2000 A |
| Rated uninterrupted current (Iu) | 2000 A |
| Current type | AC |
| Number of poles | 3 |
| Installation | Fixed |
| Trip unit | Ekip G Hi-Touch LSIG |
| Release type | Electronic |
| Protection functions | Long-time, short-time, instantaneous and earth fault (LSIG) |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 66 kA |
| Service short-circuit breaking capacity (Ics) at 400 V AC | 66 kA |
| Service short-circuit breaking capacity (Ics) at 690 V AC | 66 kA |
| Ics as percentage of Icu | 100% |
| Rated short-time withstand current (Icw), 1 s | 66 kA |
| Rated short-time withstand current (Icw), 3 s | 50 kA |
| Integrated earth-fault protection | Yes |
| Main terminal position | Rear |
| Terminal configuration | Rear flat horizontal |
| Main circuit connection | Bolt connection |
| Auxiliary contacts | 4 change-over contacts |
| Motor operator | Optional |
| Protection rating | IP30 |
| Power loss | 212 W |
| Electrical durability | 10,000 cycles at ≤440 V AC; 8,000 cycles at 500–690 V AC |
| Mechanical durability | 25,000 cycles |
| Dimensions (W × H × D) | 276 × 371 × 270 mm |
| Net weight | 41 kg |
| EAN | 8015644748906 |
| Standard | IEC 60947-2 |
The ABB 1SDA071040R1 is an Emax 2 E2.2N fixed three-pole air circuit breaker rated at 2000 A and equipped with an Ekip G Hi-Touch LSIG electronic trip unit.
The LSIG configuration provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection, with the Ekip G platform designed for advanced power and generator applications.
The E2.2N 2000 has an ultimate short-circuit breaking capacity of 66 kA at 400 V AC and maintains a 66 kA Icu rating at 690 V AC.
This model is a fixed three-pole air circuit breaker equipped with rear flat horizontal main terminals.
It is suitable for generator systems and high-current low-voltage distribution applications including industrial switchboards, main distribution panels, power distribution centres, infrastructure installations and OEM switchgear assemblies.
ABB SACE Emax 2 air circuit breakers combine high-performance fault interruption, advanced electronic protection and flexible power-system integration for dependable low-voltage distribution and generator applications.