ABB 1SDA071039R1 Emax 2 E2.2N 2000 fixed three-pole air circuit breaker with horizontal rear terminals, Ekip Hi-Touch LSIG electronic protection, 2000 A rated uninterrupted current, 690 V AC operational voltage and 66 kA short-circuit breaking capacity.
£9,881.25
The ABB 1SDA071039R1, designated E2.2N 2000 Ekip Hi-Touch LSIG 3p F HR, is a high-performance three-pole air circuit breaker (ACB) designed for advanced protection, measurement and control in demanding low-voltage power distribution systems. As part of the ABB SACE Emax 2 series, it combines a 2000 A rated uninterrupted current with the advanced Ekip Hi-Touch LSIG electronic trip unit.
The E2.2N configuration is suited to industrial, commercial, infrastructure and critical-power installations requiring high-current switching, selective protection and sophisticated electrical monitoring. Its Ekip Hi-Touch LSIG release provides long-time overload (L), short-time selective short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection, together with advanced measurement and Network Analyzer functionality.
With a rated operational voltage of 690 V AC, rated ultimate short-circuit breaking capacity of 66 kA and rated short-time withstand current of 66 kA for 1 s, the 1SDA071039R1 provides robust protection for high-current electrical networks. This version is a fixed, three-pole circuit breaker with horizontal rear terminals and is fitted with four auxiliary change-over contacts and circuit-breaker open/closed position indication.
Air circuit breakers such as the ABB SACE Emax 2 E2.2N provide switching, isolation and protection for high-current low-voltage electrical systems. With a 2000 A rated uninterrupted current, 66 kA ultimate breaking capacity and 66 kA short-time withstand current for 1 s, this configuration is suited to main distribution, transformer secondary and feeder circuits where dependable fault interruption and selective coordination are required.
The Ekip Hi-Touch LSIG electronic trip unit combines long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection with advanced measurement capabilities. Integrated Ekip Measuring Pro and Network Analyzer functionality provides enhanced visibility of electrical-system performance and power quality, while the wider ABB Ekip platform supports compatible optional communication, signalling and power-management modules.
| Series | SACE Emax 2 |
|---|---|
| Order code / MPN | 1SDA071039R1 |
| Product group | Emax2 Air Circuit Breaker |
| Product type | Air circuit breaker (ACB) |
| Frame | E2.2N |
| Short-circuit performance level | N |
| Rated uninterrupted current (Iu) | 2000 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Number of poles | 3 |
| Installation | Fixed |
| Terminal configuration | Horizontal rear flat terminals |
| Main terminal connection | Bolted |
| Trip unit | Ekip Hi-Touch LSIG |
| Trip unit type | Electronic solid-state protection release |
| Protection functions | L, S, I, G |
| Overload protection adjustment | 0.4–1 × In |
| Short-time selective protection adjustment | 0.6–10 × In |
| Instantaneous short-circuit protection adjustment | 1.5–15 × In |
| Earth-fault protection adjustment | 0.1–1 × In |
| Rated ultimate short-circuit breaking capacity (Icu) at 400/415 V AC | 66 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 66 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC | 66 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 66 kA |
| Rated service short-circuit breaking capacity (Ics) | 100% of Icu |
| Rated short-time withstand current (Icw), 1 s | 66 kA |
| Rated short-time withstand current (Icw), 3 s | 50 kA |
| Integrated earth-fault protection | Yes |
| Auxiliary change-over contacts | 4 |
| Position indication | Circuit breaker open / closed |
| Motor operator | Optional |
| Degree of protection | IP30 |
| Suitable for IT networks | Yes, up to 690 V |
| Product dimensions (W × H × D) | 276 × 371 × 270 mm |
| Product net weight | 41 kg |
| EAN | 8015644748890 |
| Standard | IEC 60947-2 |
The ABB 1SDA071039R1 is an Emax 2 air circuit breaker designed for switching, protecting and monitoring high-current low-voltage electrical distribution circuits in industrial, commercial, infrastructure and critical-power applications.
The circuit breaker has a rated uninterrupted current of 2000 A, making it suitable for high-current low-voltage distribution applications.
The Ekip Hi-Touch LSIG electronic trip unit provides long-time overload (L), short-time selective short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection, together with advanced measurement and monitoring functionality.
The E2.2N 2000 has a rated ultimate short-circuit breaking capacity of 66 kA at key operating voltages up to 690 V AC, together with a rated short-time withstand current of 66 kA for 1 s and 50 kA for 3 s.
This version is a fixed three-pole air circuit breaker with horizontal rear flat terminals, designed for permanent installation within a suitable low-voltage switchboard or switchgear assembly.
ABB SACE Emax 2 air circuit breakers combine high short-circuit performance with advanced electronic protection, measurement, power-quality analysis and expandable connectivity capabilities to provide dependable protection and intelligent power management for demanding low-voltage electrical distribution systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.