1SDA071028R1 ABB E2.2B 2000 Ekip Hi-Touch LSI 3p F HR Air Circuit Breaker

1SDA071028R1 ABB E2.2B 2000 Ekip Hi-Touch LSI 3p F HR Air Circuit Breaker

ABB 1SDA071028R1 Emax 2 E2.2B 2000 A three-pole fixed air circuit breaker with rear horizontal terminals, Ekip Hi-Touch LSI electronic protection and 42 kA ultimate breaking capacity at 400 V AC for high-current low-voltage power distribution systems.

SKU: 1SDA071028R1MPN: 1SDA071028R1
Price
List Price £11,908.18 ex VAT
Your Price (ex VAT) Save 25%
£8,931.14 25% OFF
You save £2,977.05 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,931.14
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,931.14

Why Choose the ABB E2.2B 2000 Ekip Hi-Touch LSI 3p F HR Air Circuit Breaker?

The ABB E2.2B 2000 Ekip Hi-Touch LSI 3p F HR, order code 1SDA071028R1, is a high-current air circuit breaker (ACB) from the ABB SACE Emax 2 range, engineered for protection, switching and isolation in low-voltage electrical distribution systems. Rated at 2000 A, this three-pole fixed breaker combines the E2.2B frame with ABB's advanced Ekip Hi-Touch electronic protection platform.

The breaker incorporates an Ekip Hi-Touch LSI solid-state electronic release, providing long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. Adjustable protection settings enable coordination with cables, busbars, transformers and downstream protective devices, while the Hi-Touch platform provides advanced protection, measurement and power-management capabilities for sophisticated electrical networks.

The 3p F HR configuration identifies a three-pole fixed breaker with rear horizontal terminals. The E2.2B 2000 provides a rated ultimate short-circuit breaking capacity of 42 kA at 400 V AC and is rated for operation up to 690 V AC, making the 1SDA071028R1 a robust solution for high-current main distribution and feeder applications.

Key Advantages

  • High-capacity 2000 A air circuit breaker for low-voltage power distribution.
  • Ekip Hi-Touch LSI electronic release provides adjustable overload and short-circuit protection.
  • 42 kA rated ultimate short-circuit breaking capacity at 400 V AC.
  • Rated for electrical distribution systems up to 690 V AC.
  • Three-pole fixed construction for permanent switchboard installation.
  • Rear horizontal terminals support practical rear connection within switchgear assemblies.
  • Adjustable overload protection from 800–2000 A.
  • Adjustable short-time delayed short-circuit protection from 1200–20000 A.
  • Adjustable instantaneous short-circuit protection from 3000–30000 A.
  • Ekip Hi-Touch technology supports advanced protection, measurement and power-management requirements.

Key Features

  • ABB SACE Emax 2 E2.2B air circuit breaker.
  • 2000 A rated current.
  • 3-pole configuration.
  • 690 V AC rated operational voltage.
  • 42 kA Icu at 400 V AC.
  • Ekip Hi-Touch LSI solid-state electronic release.
  • Long-time overload protection (L).
  • Short-time delayed short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Fixed installation with rear horizontal terminals.
  • Bolt-connected main circuit.
  • 4 change-over auxiliary contacts.
  • Breaker open/closed position indication.
  • Optional motor-operated mechanism capability.
  • Mechanical durability of 25,000 operating cycles.

Advanced Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 E2.2B provide switching, isolation and electronic protection for high-current low-voltage installations. The Ekip Hi-Touch platform combines configurable protection with advanced measurement and power-management functionality, supporting effective coordination and management of modern electrical distribution networks.

The Ekip Hi-Touch LSI release combines long-time, short-time delayed and instantaneous protection within a single electronic protection unit. Together with its 2000 A rated current, 42 kA ultimate breaking capacity at 400 V AC and 42 kA short-time withstand current for 1 s, the 1SDA071028R1 provides dependable protection for main switchboards, transformer distribution circuits and high-current feeders.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial electrical distribution systems.
  • Commercial and infrastructure power distribution.
  • Incoming mains and high-current feeder protection.
  • Transformer secondary distribution circuits.
  • Manufacturing and process-industry switchboards.
  • Large building and facility distribution systems.
  • Distribution networks requiring advanced LSI electronic protection.

Technical Specifications

Series SACE Emax 2
Frame E2.2B
ABB order code 1SDA071028R1
Product type Air circuit breaker (ACB)
Rated current (In) 2000 A
Rated uninterrupted current (Iu) 2000 A
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V AC
Rated impulse withstand voltage 12 kV
Frequency 50/60 Hz
Rated ultimate short-circuit breaking capacity at 400 V AC 42 kA
Rated short-time withstand current 42 kA for 1 s
Number of poles 3
Protection trip unit Ekip Hi-Touch LSI
Release technology Solid-state electronic release
Protection functions Long-time, short-time and instantaneous (LSI)
Overload release adjustment range 800–2000 A
Short-time delayed short-circuit release adjustment range 1200–20000 A
Instantaneous short-circuit release adjustment range 3000–30000 A
Integrated ground-fault protection No
Current type AC
Installation Fixed
Main-circuit terminals Rear horizontal (HR)
Main-circuit connection Bolt connection
Connecting capacity 1800 mm²
Auxiliary contacts 4 change-over contacts
Open/closed position indication Yes
Integrated undervoltage release No
Integrated motor drive No
Motor drive Optional
Electrical durability at ≤440 V 10,000 operating cycles
Electrical durability at 500–690 V 8,000 operating cycles
Mechanical durability 25,000 operating cycles
Power loss 212 W
Dimensions (W × H × D) 276 × 371 × 270 mm
Net weight 41 kg
EAN 8015644748784
Product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA071028R1?

The ABB 1SDA071028R1 is a SACE Emax 2 E2.2B 2000 Ekip Hi-Touch LSI 3p F HR air circuit breaker rated at 2000 A, with three-pole fixed construction, rear horizontal terminals and an Ekip Hi-Touch LSI electronic release.

What is the rated current of the ABB E2.2B 2000 Ekip Hi-Touch LSI?

The breaker has a rated current of 2000 A, making it suitable for high-current low-voltage electrical distribution applications.

What protection functions does the Ekip Hi-Touch LSI release provide?

The Ekip Hi-Touch LSI release provides long-time overload protection (L), short-time delayed short-circuit protection (S) and instantaneous short-circuit protection (I).

What is the breaking capacity of the ABB 1SDA071028R1?

The E2.2B 2000 provides a rated ultimate short-circuit breaking capacity of 42 kA at 400 V AC, together with a rated short-time withstand current of 42 kA for 1 s.

Does the ABB 1SDA071028R1 include ground-fault protection?

No. This configuration uses an Ekip Hi-Touch LSI release providing long-time, short-time and instantaneous protection; integrated ground-fault protection is not included in the LSI configuration.

What does F HR mean on the ABB E2.2B 2000?

The F HR designation identifies a fixed-version breaker with rear horizontal terminals, providing a rear connection arrangement for integration into compatible low-voltage switchboards.

Is the ABB E2.2B 2000 1SDA071028R1 fixed or withdrawable?

The 1SDA071028R1 is a fixed-version air circuit breaker, intended for permanent installation within a compatible low-voltage switchboard or distribution assembly.

Trusted by Electrical Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers are engineered for reliable protection, switching and power management in low-voltage electrical distribution systems, supporting demanding industrial, commercial and infrastructure installations.