Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA071021R1 Emax 2 E2.2B 2000 fixed three-pole air circuit breaker with horizontal rear terminals, Ekip Dip LI electronic protection, 2000 A rated current, 690 V AC operational voltage and 42 kA short-circuit breaking capacity.
£5,905.37
The ABB 1SDA071021R1, designated E2.2B 2000 Ekip Dip LI 3p F HR, is a three-pole air circuit breaker (ACB) designed for reliable switching and protection in high-current low-voltage power distribution systems. As part of the ABB SACE Emax 2 series, it combines a 2000 A rated current with the Ekip Dip LI electronic trip unit for dependable overload and instantaneous short-circuit protection.
The E2.2B configuration is suited to industrial, commercial and infrastructure installations requiring robust high-current circuit protection. Its Ekip Dip LI electronic release provides long-time overload (L) and instantaneous short-circuit (I) protection, with settings made through DIP switches for straightforward commissioning and coordination with the electrical installation.
With a rated operational voltage of 690 V AC, rated ultimate short-circuit breaking capacity of 42 kA and rated short-time withstand current of 42 kA for 1 s, the 1SDA071021R1 provides dependable protection for high-current distribution networks. This version is a fixed, three-pole circuit breaker with horizontal rear terminals, providing a practical configuration for permanent integration into low-voltage switchboards.
Air circuit breakers such as the ABB SACE Emax 2 E2.2B provide switching, isolation and protection for high-current low-voltage electrical systems. With a 2000 A current rating, 42 kA ultimate short-circuit breaking capacity and 42 kA short-time withstand capability for 1 s, this configuration is suitable for main distribution, transformer secondary and feeder circuits requiring dependable interruption of substantial fault currents.
The Ekip Dip LI electronic trip unit provides adjustable long-time overload and instantaneous short-circuit protection. Its overload setting range of 800–2000 A and instantaneous setting range of 3000–30000 A allow the protection characteristics to be coordinated with the electrical installation, while DIP-switch adjustment provides a straightforward method of configuring the principal protection parameters.
| Series | SACE Emax 2 |
|---|---|
| Order code / MPN | 1SDA071021R1 |
| Product group | Emax2 Air Circuit Breaker |
| Product type | Air circuit breaker (ACB) |
| Frame | E2.2B |
| Performance level | B |
| Rated current | 2000 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Frequency | 50/60 Hz |
| Number of poles | 3 |
| Installation | Fixed |
| Terminal configuration | Horizontal rear terminals |
| Trip unit | Ekip Dip LI |
| Trip unit type | Electronic protection release |
| Protection functions | L, I |
| Overload protection setting range | 800–2000 A |
| Instantaneous short-circuit protection setting range | 3000–30000 A |
| Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 400/415 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 42 kA |
| Rated short-time withstand current (Icw), 1 s | 42 kA |
| Protection adjustment | DIP switches |
| Standard | IEC 60947-2 |
The ABB 1SDA071021R1 is an Emax 2 air circuit breaker designed for switching and protecting high-current low-voltage electrical distribution circuits against overloads and short circuits.
The circuit breaker has a rated current of 2000 A, with an adjustable long-time overload protection range of 800–2000 A.
The Ekip Dip LI electronic trip unit provides long-time overload (L) and instantaneous short-circuit (I) protection, with the principal protection settings configured using DIP switches.
The E2.2B 2000 has a rated ultimate short-circuit breaking capacity of 42 kA at operating voltages including 380 V AC, 400/415 V AC, 440 V AC, 500/525 V AC and 690 V AC, together with a rated short-time withstand current of 42 kA for 1 s.
This version is a fixed three-pole air circuit breaker with horizontal rear terminals, designed for permanent installation within a suitable low-voltage switchboard or switchgear assembly.
ABB SACE Emax 2 air circuit breakers combine dependable short-circuit performance with configurable electronic protection and practical installation options to provide reliable switching and protection for demanding low-voltage electrical distribution systems.
We use cookies