ABB 1SDA071005R1 Emax 2 E2.2S 1600 fixed three-pole air circuit breaker with horizontal rear terminals, Ekip Touch LSI electronic protection, 1600 A rated uninterrupted current and 85 kA breaking capacity at 400–440 V AC.
£5,510.72
The ABB 1SDA071005R1, designated E2.2S 1600 Ekip Touch LSI 3p F HR, is a high-performance three-pole air circuit breaker (ACB) designed for reliable switching, protection and monitoring in demanding low-voltage power distribution systems. As part of the ABB SACE Emax 2 series, it combines a 1600 A rated uninterrupted current with the Ekip Touch LSI electronic trip unit for comprehensive overload and short-circuit protection.
The E2.2S is engineered for industrial, commercial and infrastructure installations where high breaking performance and selective electronic protection are required. Its Ekip Touch LSI release provides long-time overload (L), short-time selective short-circuit (S) and instantaneous short-circuit (I) protection, allowing effective coordination between upstream and downstream protective devices within the electrical distribution system.
With a rated uninterrupted current of 1600 A, rated ultimate short-circuit breaking capacity of 85 kA at 440 V AC and rated short-time withstand current of 66 kA for 1 s, the 1SDA071005R1 provides robust protection for high-current distribution networks. This version is a fixed, three-pole circuit breaker with horizontal rear terminals, providing a practical arrangement for permanent integration into low-voltage switchboards and switchgear assemblies.
Air circuit breakers such as the ABB SACE Emax 2 E2.2S provide switching, isolation and protection for high-current low-voltage electrical distribution systems. With a 1600 A current rating, 85 kA ultimate breaking capacity at 400–440 V AC and 66 kA short-time withstand current for 1 s, this configuration is well suited to main distribution, transformer secondary and feeder circuits where dependable fault interruption and selective coordination are important.
The Ekip Touch LSI electronic trip unit combines long-time overload, short-time selective short-circuit and instantaneous short-circuit protection. The inclusion of adjustable short-time protection makes the LSI configuration particularly suitable for systems where discrimination between upstream and downstream protective devices is required, while the Ekip Touch platform provides convenient access to protection settings, measurements and operating information.
| Series | SACE Emax 2 |
|---|---|
| Order code / MPN | 1SDA071005R1 |
| Product group | Emax2 Air Circuit Breaker |
| Product type | Air circuit breaker (ACB) |
| Frame | E2.2S |
| Performance level | S |
| Rated uninterrupted current (Iu) | 1600 A |
| Rated operational voltage | 690 V AC |
| Number of poles | 3 |
| Installation | Fixed |
| Terminal configuration | Horizontal rear terminals |
| Trip unit | Ekip Touch LSI |
| Trip unit type | Electronic protection release |
| Protection functions | L, S, I |
| Long-time overload protection setting range | 640–1600 A |
| Short-time selective protection setting range | 960–16000 A |
| Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC | 85 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC | 85 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 85 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC | 66 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 66 kA |
| Rated short-time withstand current (Icw), 1 s | 66 kA |
| Rated short-time withstand current (Icw), 3 s | 50 kA |
| EAN | 8015644748555 |
The ABB 1SDA071005R1 is an Emax 2 air circuit breaker designed for switching, protecting and monitoring high-current low-voltage electrical distribution circuits against overloads and short circuits.
The circuit breaker has a rated uninterrupted current of 1600 A, with a long-time overload protection setting range of 640–1600 A.
The Ekip Touch LSI electronic trip unit provides long-time overload (L), short-time selective short-circuit (S) and instantaneous short-circuit (I) protection, making it suitable for distribution systems where selective coordination is required.
The E2.2S 1600 has a rated ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC, together with a rated short-time withstand current of 66 kA for 1 s.
This version is a fixed three-pole air circuit breaker with horizontal rear terminals, designed for permanent installation within a suitable low-voltage switchboard or switchgear assembly.
ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, advanced electronic protection and selective coordination capabilities to provide dependable switching and protection for demanding low-voltage electrical distribution systems.