Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA070996R1 Emax 2 E2.2N 1600 A three-pole fixed air circuit breaker with rear horizontal terminals, Ekip Touch LSIG electronic protection and 66 kA ultimate breaking capacity at 400 V AC for demanding low-voltage power distribution systems.
£5,452.23
The ABB E2.2N 1600 Ekip Touch LSIG 3p F HR, order code 1SDA070996R1, is a high-performance air circuit breaker (ACB) from the ABB SACE Emax 2 range, engineered for protection, switching and isolation in demanding low-voltage electrical distribution systems. Rated at 1600 A, this three-pole fixed breaker combines the E2.2N frame with ABB's advanced Ekip Touch electronic protection technology.
The breaker incorporates an Ekip Touch LSIG electronic trip unit, providing long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection. Adjustable electronic protection enables the breaker to be coordinated with cables, busbars, transformers and downstream protective devices while the Ekip Touch interface supports straightforward configuration and monitoring of protection functions.
The 3p F HR configuration identifies a three-pole fixed breaker with rear horizontal terminals. With a rated ultimate short-circuit breaking capacity of 66 kA at 400 V AC and a rated operational voltage of 690 V AC, the 1SDA070996R1 provides robust protection for high-current industrial, commercial and infrastructure distribution systems.
Air circuit breakers such as the ABB SACE Emax 2 E2.2N protect high-current low-voltage installations against overloads, short circuits and ground faults while providing controlled switching and isolation. The Ekip Touch electronic platform combines configurable protection with measurement and monitoring capabilities, supporting effective coordination and management of sophisticated electrical distribution networks.
The Ekip Touch LSIG release combines long-time, short-time, instantaneous and ground-fault protection within a single electronic protection unit. Together with its 1600 A rated current, 690 V AC operational voltage and 66 kA ultimate breaking capacity at 400 V AC, the 1SDA070996R1 provides a robust protection solution for high-current switchboards and critical distribution feeders.
| Series | SACE Emax 2 |
|---|---|
| Frame | E2.2N |
| ABB order code | 1SDA070996R1 |
| Product type | Air circuit breaker (ACB) |
| Rated current | 1600 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage | 1000 V AC |
| Frequency | 50/60 Hz |
| Rated ultimate short-circuit breaking capacity at 400 V AC | 66 kA |
| Number of poles | 3 |
| Protection trip unit | Ekip Touch LSIG |
| Protection functions | Long-time, short-time, instantaneous and ground-fault (LSIG) |
| Overload protection adjustment range | 640–1600 A |
| Short-time short-circuit protection adjustment range | 960–16000 A |
| Instantaneous short-circuit protection adjustment range | 2400–24000 A |
| Integrated ground-fault protection | Yes |
| Current type | AC |
| Installation | Fixed |
| Main-circuit terminal position | Rear |
| Terminal orientation | Horizontal (HR) |
| Main-circuit connection | Bolt connection |
| Auxiliary contacts | 4 change-over contacts |
| Switched-off indication | Yes |
| Integrated undervoltage release | No |
| Integrated motor drive | No |
| Motor drive | Optional |
| Protection rating | IP30 |
| Power loss | 136 W |
| EAN | 8015644748463 |
| Product group | Emax2 Air Circuit Breaker |
The ABB 1SDA070996R1 is a SACE Emax 2 E2.2N 1600 Ekip Touch LSIG 3p F HR air circuit breaker rated at 1600 A, with three-pole fixed construction, rear horizontal terminals and an Ekip Touch LSIG electronic protection unit.
The breaker has a rated current of 1600 A, making it suitable for high-current low-voltage electrical distribution applications.
The Ekip Touch LSIG trip unit provides long-time overload protection (L), short-time short-circuit protection (S), instantaneous short-circuit protection (I) and ground-fault protection (G).
The E2.2N 1600 has a rated ultimate short-circuit breaking capacity of 66 kA at 400 V AC, providing high fault-clearing capability for demanding low-voltage distribution systems.
Yes. The Ekip Touch LSIG trip unit includes integrated ground-fault protection in addition to long-time, short-time and instantaneous overcurrent protection.
The F HR designation identifies a fixed-version breaker with rear horizontal terminals, providing a rear connection arrangement for integration into compatible low-voltage switchboards.
The 1SDA070996R1 is a fixed-version air circuit breaker, intended for permanent installation within a compatible low-voltage switchboard or distribution assembly.
ABB SACE Emax 2 air circuit breakers are engineered for reliable protection, switching and management of low-voltage electrical distribution systems, supporting demanding industrial, commercial and infrastructure installations.