1SDA070971R1 ABB E2.2H 1250 Ekip Dip LI 3p FHR Air Circuit Breaker

1SDA070971R1 ABB E2.2H 1250 Ekip Dip LI 3p FHR Air Circuit Breaker

ABB 1SDA070971R1 Emax 2 E2.2H 1250 fixed three-pole air circuit breaker with rear horizontal terminals, a 1250 A rated uninterrupted current, Ekip Dip LI electronic trip unit, 100 kA ultimate short-circuit breaking capacity at 400–440 V AC and 85 kA short-time withstand current for 1 s.

SKU: 1SDA070971R1MPN: 1SDA070971R1
Price
List Price £6,918.86 ex VAT
Your Price (ex VAT) Save 25%
£5,189.15 25% OFF
You save £1,729.72 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,189.15
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,189.15

Why Choose the ABB E2.2H 1250 Ekip Dip LI 3p FHR Air Circuit Breaker?

The ABB E2.2H 1250 Ekip Dip LI 3p FHR, order code 1SDA070971R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for switching and protection in demanding low-voltage electrical distribution systems. Part of the ABB Emax 2 E2.2 series, this fixed three-pole circuit breaker combines a 1250 A rated uninterrupted current with an Ekip Dip LI electronic trip unit and rear horizontal terminals.

The Ekip Dip LI solid-state electronic release provides long-time overload protection and instantaneous short-circuit protection. This straightforward LI protection configuration is well suited to distribution circuits where dependable electronic overcurrent protection is required without integrated short-time selective or earth-fault protection functions.

The E2.2H performance class provides substantial fault-interruption capability, including a rated ultimate short-circuit breaking capacity of 100 kA at 400–440 V AC and 85 kA at 690 V AC. The ABB 1SDA070971R1 also provides a rated short-time withstand current of 85 kA for 1 s, making it suitable for high-fault-level switchboards, main distribution circuits and demanding industrial power systems.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding low-voltage distribution systems.
  • 1250 A rated uninterrupted current for high-current electrical loads.
  • 100 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 85 kA ultimate short-circuit breaking capacity at 690 V AC.
  • 85 kA short-time withstand current for 1 s.
  • Ekip Dip LI electronic trip unit for overload and instantaneous short-circuit protection.
  • Service short-circuit breaking capacity equal to 100% of Icu.
  • Fixed three-pole construction with rear horizontal terminals for permanent switchboard integration.

Key Features

  • ABB SACE Emax 2 E2.2H series.
  • 1250 A rated uninterrupted current.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Three-pole configuration.
  • Fixed version for permanent installation.
  • Rear flat horizontal terminal arrangement.
  • Ekip Dip LI solid-state electronic release.
  • Long-time overload protection (L).
  • Instantaneous short-circuit protection (I).
  • 100 kA Icu at 400, 415 and 440 V AC.
  • 85 kA Icu at 500, 525 and 690 V AC.
  • 85 kA Icw for 1 s and 66 kA Icw for 3 s.
  • Four auxiliary change-over contacts with open/closed circuit-breaker position indication.
  • Suitable for IT networks up to 690 V.
  • IP30 degree of protection.

High Breaking Capacity with LI Circuit Protection

The ABB SACE Emax 2 E2.2H is engineered for low-voltage installations where substantial prospective short-circuit currents require high interruption and withstand capability. With 100 kA Icu at 400–440 V AC, 85 kA Icu at 690 V AC and an Ics value equal to 100% of Icu, the E2.2H 1250 provides robust fault-clearing performance for main distribution circuits, transformer secondary systems and high-power industrial installations.

The Ekip Dip LI electronic trip unit concentrates on two fundamental protection functions. Long-time protection safeguards cables, busbars and connected equipment against sustained overload conditions, while instantaneous protection provides rapid interruption of severe short circuits. This makes the ABB 1SDA070971R1 particularly suitable where straightforward electronic overcurrent protection is required without integrated short-time selective or earth-fault functions.

Typical Applications

  • Low-voltage main distribution switchboards.
  • High-fault-level electrical distribution systems.
  • Main incomer and high-current feeder circuits.
  • Industrial power distribution networks.
  • Commercial and large-building electrical distribution.
  • Manufacturing plants and process facilities.
  • Transformer secondary distribution systems.
  • Infrastructure and utility installations.
  • Data centres and critical power distribution.
  • Electrical switchgear and panel building.

Technical Specifications

Series SACE Emax 2
Frame E2.2H
Product ID / order code 1SDA070971R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker
Rated uninterrupted current (Iu) 1250 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Number of poles 3
Version Fixed
Terminal arrangement Rear flat horizontal
Main circuit connection Bolt connection
Trip unit Ekip Dip LI
Release type Electronic
Protection functions LI
Long-time overload protection (L) Included
Instantaneous short-circuit protection (I) Included
Short-time selective protection (S) Not included
Integrated earth-fault protection (G) No
Rated ultimate short-circuit breaking capacity (Icu) 100 kA at 400 V AC
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw) 85 kA for 1 s
Auxiliary contacts 4 change-over contacts
Breaker position indication Open / closed
Degree of protection IP30
Suitable for IT networks Yes, up to 690 V
Power loss 83 W
Product dimensions 276 × 371 × 270 mm
Product net weight 41 kg
Standard IEC
EAN 8015644748210

Frequently Asked Questions

What is the ABB 1SDA070971R1 used for?

The ABB 1SDA070971R1 is an Emax 2 air circuit breaker designed for switching and protecting demanding low-voltage electrical distribution circuits, particularly applications requiring high short-circuit breaking capacity and electronic overload and instantaneous short-circuit protection.

What is the rated current of the ABB E2.2H 1250?

The ABB E2.2H 1250 Ekip Dip LI has a rated uninterrupted current of 1250 A, making it suitable for substantial low-voltage electrical loads.

What is the breaking capacity of the ABB E2.2H 1250?

The E2.2H 1250 provides a rated ultimate short-circuit breaking capacity of 100 kA at 400–440 V AC and 85 kA at 690 V AC. Its rated service short-circuit breaking capacity is 100% of Icu.

What protection does the Ekip Dip LI trip unit provide?

The Ekip Dip LI electronic trip unit provides long-time overload and instantaneous short-circuit protection. The LI configuration does not include integrated short-time selective or earth-fault protection.

What does FHR mean on the ABB E2.2H 1250?

For the ABB 1SDA070971R1 configuration, FHR identifies a fixed air circuit breaker with rear horizontal terminals, providing a rear connection arrangement for integration into compatible low-voltage switchboards.

Trusted for High-Fault-Level Power Distribution

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance with dependable electronic protection, providing robust switching and circuit protection for demanding industrial, commercial, infrastructure and critical low-voltage power distribution systems.