1SDA068195R1 ABB XT3 P FP 4p HR Fixed Part for Plug-In Circuit Breaker

1SDA068195R1 ABB XT3 P FP 4p HR Fixed Part for Plug-In Circuit Breaker

ABB 1SDA068195R1 XT3 P FP 4p HR is a 250 A four-pole fixed part for compatible plug-in SACE Tmax XT3 moulded case circuit breakers, featuring horizontal rear terminals and operational ratings up to 690 V AC and 500 V DC.

SKU: 1SDA068195R1MPN: 1SDA068195R1
Price
List Price £365.67 ex VAT
Your Price (ex VAT) Save 25%
£274.25 25% OFF
You save £91.42 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £274.25
Trade pricing is personalised to your account

Manufacturer Lead Time

£274.25

Why Choose the ABB XT3 P FP 4p HR Fixed Part?

The ABB XT3 P FP 4p HR, order code 1SDA068195R1, is a four-pole fixed part for plug-in ABB SACE Tmax XT3 moulded case circuit breakers. Part of the ABB T-Max XT 250 Range, it forms the fixed installation base for a compatible plug-in XT3 circuit breaker, enabling the removable breaker section to be connected to the electrical system.

Designed for 250 A rated uninterrupted current, the fixed part features horizontal rear terminals and a four-pole configuration. The rear-terminal arrangement supports installations where the main power connections are routed behind the circuit breaker, while the plug-in architecture simplifies removal and replacement of the compatible breaker without disturbing the fixed main connections.

The 1SDA068195R1 is rated for operation up to 690 V AC and 500 V DC, with an insulation voltage of 800 V and impulse withstand voltage of 8 kV. It is designed for use with compatible ABB Tmax XT3 plug-in circuit breakers in industrial switchboards, distribution panels and other low-voltage electrical assemblies.

Key Advantages

  • Genuine ABB SACE Tmax XT3 fixed part for plug-in circuit-breaker installations.
  • 250 A rated uninterrupted current for Tmax XT3 applications.
  • Four-pole configuration for three-phase four-wire electrical systems.
  • Horizontal rear terminals support clean rear-connected switchboard layouts.
  • Plug-in architecture allows the compatible circuit breaker to be removed while the fixed connections remain installed.
  • Rated for operation up to 690 V AC and 500 V DC.
  • 800 V rated insulation voltage and 8 kV impulse withstand voltage.
  • Designed for dependable integration with compatible ABB Tmax XT3 circuit breakers.

Key Features

  • ABB SACE Tmax XT3 compatible.
  • XT3 P FP plug-in fixed-part configuration.
  • 250 A rated uninterrupted current.
  • Four-pole construction.
  • Horizontal rear terminals.
  • Main-circuit bolt connections.
  • Rated operational voltage up to 690 V AC.
  • Rated operational voltage up to 500 V DC.
  • Rated insulation voltage of 800 V.
  • Rated impulse withstand voltage of 8 kV.
  • Rated frequency of 50/60 Hz.
  • Designed as the fixed base for a compatible plug-in XT3 circuit breaker.

Flexible Plug-In Installation for Tmax XT3 Circuit Breakers

A plug-in circuit-breaker arrangement separates the removable circuit breaker from the permanently wired fixed part. The XT3 P FP 4p HR remains connected to the main electrical conductors, while a compatible plug-in Tmax XT3 circuit breaker can be installed or removed from the fixed base. This arrangement can simplify maintenance and circuit-breaker replacement within suitably designed switchboards.

The horizontal rear-terminal configuration routes the main electrical connections behind the breaker assembly, helping support organised switchboard layouts where rear access is available. With a 250 A current rating, four-pole construction and voltage capability up to 690 V AC, the 1SDA068195R1 provides a robust fixed interface for compatible XT3 plug-in circuit breakers.

Typical Applications

  • ABB Tmax XT3 plug-in circuit-breaker assemblies.
  • Industrial low-voltage switchboards.
  • Commercial power distribution panels.
  • Three-phase four-wire distribution systems.
  • Industrial machinery and control panels.
  • Building-services electrical distribution.
  • Switchboards requiring rear-connected power terminals.

Technical Specifications

Series SACE Tmax XT3
Product group T-Max XT 250 Range
Order code 1SDA068195R1
Product type Fixed part for plug-in moulded case circuit breaker
Compatible frame ABB SACE Tmax XT3
Rated uninterrupted current 250 A
Number of poles 4
Installation configuration Plug-in fixed part
Terminal orientation Horizontal rear terminals
Main-circuit connection Bolt connection
Rated operational voltage AC up to 690 V AC
Rated operational voltage DC up to 500 V DC
Rated insulation voltage Ui 800 V
Rated impulse withstand voltage Uimp 8 kV
Rated frequency 50/60 Hz
Standards IEC 60947-2, UL 489
RoHS Compliant
Product net weight 1.41 kg
EAN 8015644696283

Frequently Asked Questions

What is the ABB 1SDA068195R1?

The ABB 1SDA068195R1 is an XT3 P FP four-pole fixed part for compatible plug-in ABB SACE Tmax XT3 moulded case circuit breakers, featuring horizontal rear terminals and a 250 A rated uninterrupted current.

Is the ABB 1SDA068195R1 a complete circuit breaker?

No. The 1SDA068195R1 is the fixed part of a plug-in circuit-breaker system. A compatible plug-in ABB Tmax XT3 circuit breaker is required to form the complete protective switching assembly.

What does HR mean on the ABB XT3 P FP 4p HR?

HR identifies the horizontal rear-terminal configuration. The main power connections are positioned at the rear of the fixed part and supplied in the horizontal terminal orientation.

What is the current rating of the ABB XT3 P FP 4p HR?

The 1SDA068195R1 has a rated uninterrupted current of 250 A and is designed for compatible ABB SACE Tmax XT3 plug-in circuit breakers.

What voltage ratings does the ABB 1SDA068195R1 support?

The fixed part is rated for operational voltages up to 690 V AC and 500 V DC, with a rated insulation voltage of 800 V and rated impulse withstand voltage of 8 kV.

Trusted ABB Circuit Breaker Accessories

ABB SACE Tmax XT fixed parts provide a robust connection interface for plug-in moulded case circuit breakers, supporting flexible installation, maintenance and replacement within industrial, commercial and infrastructure electrical distribution systems.