ABB 1SDA067949R1 XT2L 160 Ekip LS/I In=63A 4p F F is a 63 A four-pole fixed moulded case circuit breaker with an Ekip LS/I electronic trip unit providing configurable overload and short-circuit protection for low-voltage AC distribution systems.
£838.64
The ABB XT2L 160 Ekip LS/I In=63A 4p F F, order code 1SDA067949R1, is a high-performance four-pole moulded case circuit breaker (MCCB) designed for dependable protection of low-voltage AC power distribution systems. As part of the ABB SACE Tmax XT series, it combines the compact XT2 frame with an Ekip LS/I solid-state electronic trip unit and the high short-circuit performance of the XT2L configuration.
This circuit breaker is equipped with an Ekip LS/I electronic release rated at 63 A. Its protection functions include long-time overload, short-time short-circuit and instantaneous short-circuit protection, with an overload setting range of 25.2–63 A and short-circuit adjustment up to 630 A, enabling flexible protection coordination within industrial and commercial distribution systems.
The XT2L 160 Ekip LS/I In=63A is a fixed four-pole circuit breaker with front terminals for straightforward integration into switchboards and distribution panels. It is rated for operation up to 690 V AC and provides an ultimate short-circuit breaking capacity of 120 kA at 415 V AC, making it suitable for demanding installations with high prospective fault currents.
Electronic moulded case circuit breakers provide precise and configurable protection for electrical distribution circuits. The ABB Ekip LS/I release combines long-time overload, short-time short-circuit and instantaneous short-circuit functions, allowing protection settings to be coordinated with conductors, downstream equipment and the electrical characteristics of the installation.
The Tmax XT platform is designed for compact industrial switchboards and power distribution systems where dependable interruption of high prospective fault currents is essential. The XT2L configuration combines high breaking performance with compact dimensions, while its fixed front-connected construction supports efficient integration into switchboards, control panels and OEM electrical assemblies.
| Series | SACE Tmax XT |
|---|---|
| ABB order code | 1SDA067949R1 |
| Product type | Moulded case circuit breaker |
| Frame size | XT2 |
| Short-circuit performance level | L |
| Number of poles | 4 |
| Rated current (In) | 63 A |
| Rated uninterrupted current (Iu) | 160 A |
| Trip unit | Ekip LS/I |
| Release type | EL solid-state electronic |
| Protection functions | Long-time, short-time and instantaneous |
| Overload release setting range | 25.2–63 A |
| Short-time delayed short-circuit adjustment | 63–630 A |
| Instantaneous short-circuit adjustment | 63–630 A |
| Rated operational voltage | 690 V AC |
| Rated voltage (Ur) | 690 V |
| Rated insulation voltage (Ui) | 1,000 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Rated frequency | 50 / 60 Hz |
| Ultimate breaking capacity (Icu) at 220–240 V AC | 150 kA |
| Ultimate breaking capacity (Icu) at 380–415 V AC | 120 kA |
| Ultimate breaking capacity (Icu) at 440 V AC | 100 kA |
| Ultimate breaking capacity (Icu) at 500 V AC | 60 kA |
| Ultimate breaking capacity (Icu) at 525 V AC | 36 kA |
| Ultimate breaking capacity (Icu) at 690 V AC | 18 kA |
| Service breaking capacity (Ics) at 380–415 V AC | 120 kA |
| Service breaking capacity (Ics) at 690 V AC | 15 kA |
| Power loss | 1.7 W per pole at rated operating conditions |
| Mechanical durability | 25,000 operations |
| Electrical durability | 8,000 operations |
| Mounting | Fixed |
| Terminal connection | Front |
| Terminal type | Bolt |
| Main circuit tightening torque | 6 N·m |
| Dimensions (W × H × D) | 120 × 130 × 82.5 mm |
| Net weight | approx. 1.5 kg |
| EAN | 8015644695767 |
| Country of origin | Italy |
| Standard | IEC 60947-2 |
The ABB 1SDA067949R1 is a four-pole moulded case circuit breaker designed to provide configurable electronic overload and short-circuit protection in low-voltage AC power distribution systems.
The circuit breaker is fitted with a 63 A Ekip LS/I electronic trip unit and is built on the ABB XT2 160 frame.
The Ekip LS/I release provides long-time overload protection, short-time delayed short-circuit protection and instantaneous short-circuit protection for coordinated electrical distribution protection.
This XT2L model provides an ultimate short-circuit breaking capacity of 120 kA at 415 V AC, with breaking capacity varying according to the operating voltage.