1SDA067658R1 ABB XT2L 160 TMD 12.5-125 4P F F Moulded-Case Circuit Breaker

1SDA067658R1 ABB XT2L 160 TMD 12.5-125 4P F F Moulded-Case Circuit Breaker

ABB 1SDA067658R1 is a 12.5 A four-pole SACE Tmax XT2L 160 moulded-case circuit-breaker with a TMD thermomagnetic release, adjustable 8.75–12.5 A overload protection, 125 A magnetic short-circuit protection and fixed front terminals.

SKU: 1SDA067658R1MPN: 1SDA067658R1
Price
List Price £605.69 ex VAT
Your Price (ex VAT) Save 25%
£454.27 25% OFF
You save £151.42 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £454.27
Trade pricing is personalised to your account

Manufacturer Lead Time

£454.27

Why Choose the ABB XT2L 160 TMD 12.5-125 4P F F Circuit Breaker?

The ABB 1SDA067658R1 is a complete SACE Tmax XT2L 160 moulded-case circuit-breaker designed for low-voltage power distribution. Identified by ABB as XT2L 160 TMD 12.5-125 4P F F, it combines a four-pole configuration with fixed mounting, front terminals and an integrated TMD thermomagnetic release.

The integrated TMD thermomagnetic release has a rated current of 12.5 A and provides both overload and short-circuit protection. Its thermal overload setting is adjustable from 8.75–12.5 A, while the magnetic short-circuit trip threshold is 125 A, providing rapid protection against high fault currents.

The XT2L performance level is designed for installations requiring high short-circuit interruption capability. Combined with its compact XT2 frame, four-pole construction, 690 V rated voltage, fixed installation and front terminals, the 1SDA067658R1 provides a robust protection solution for industrial and commercial distribution systems.

Key Advantages

  • Complete ABB SACE Tmax XT2L 160 moulded-case circuit-breaker.
  • 12.5 A TMD thermomagnetic release for overload and short-circuit protection.
  • Adjustable thermal overload setting from 8.75–12.5 A.
  • 125 A magnetic short-circuit trip threshold.
  • Four-pole configuration for three-phase four-wire distribution systems.
  • High-performance XT2L interruption class for demanding fault conditions.
  • Fixed construction with front terminals for switchboard integration.

Key Features

  • ABB SACE Tmax XT2L 160 moulded-case circuit-breaker.
  • TMD thermomagnetic release.
  • 12.5 A rated current.
  • Adjustable thermal overload protection from 8.75–12.5 A.
  • Magnetic short-circuit protection at 125 A.
  • Magnetic trip threshold equivalent to 10 × In.
  • Four-pole configuration.
  • Fixed installation.
  • Front terminals for main circuit connections.
  • Rated voltage of 690 V.
  • L short-circuit performance level.
  • Designed for power distribution applications.
  • Part of the ABB SACE Tmax XT moulded-case circuit-breaker range.
  • Designed to applicable IEC requirements.

Thermomagnetic Protection for Four-Pole Distribution Circuits

Thermomagnetic circuit-breakers combine thermal protection for sustained overload conditions with magnetic protection for short-circuit faults. On the ABB 1SDA067658R1, the thermal element can be adjusted from 8.75–12.5 A, allowing the overload setting to be coordinated with the protected conductors and connected equipment.

The magnetic element provides short-circuit protection at 125 A, equivalent to 10 × In. Combined with the high-performance XT2L breaking unit and four-pole construction, this provides dependable protection for industrial and commercial distribution circuits where all four conductors require switching.

Typical Applications

  • Industrial low-voltage distribution switchboards.
  • Commercial building electrical distribution.
  • Three-phase four-wire feeder circuits.
  • Control panel and auxiliary distribution circuits.
  • Machinery and production equipment power supplies.
  • Installations requiring high short-circuit interruption performance.

Technical Specifications

Product group T-Max XT 250 Range
Series SACE Tmax XT2
Performance level XT2L
Frame size XT2 160
ABB order code 1SDA067658R1
EAN / GTIN 8015644015541
Product type Moulded-case circuit-breaker
Trip unit TMD thermomagnetic release
Release type Thermomagnetic
Rated current (In) 12.5 A
Thermal overload setting 8.75–12.5 A
Thermal adjustment 0.7–1 × In
Magnetic short-circuit setting 125 A
Magnetic trip threshold 10 × In
Protection functions Thermal overload and magnetic short-circuit protection
Number of poles 4
Rated voltage 690 V
Short-circuit performance level L
Mounting Fixed
Main terminals Front terminals
Application Power distribution
Standard IEC
Country of origin Italy
Gross weight 1.55 kg

Frequently Asked Questions

What is the ABB 1SDA067658R1?

The ABB 1SDA067658R1 is a complete XT2L 160 four-pole moulded-case circuit-breaker with fixed mounting, front terminals and a 12.5 A TMD thermomagnetic release.

What is the rated current of the ABB 1SDA067658R1?

The TMD thermomagnetic release has a rated current of 12.5 A.

What is the thermal overload setting range?

The thermal overload protection is adjustable from 8.75–12.5 A, corresponding to 0.7–1 × In.

What is the magnetic short-circuit trip setting?

The magnetic short-circuit trip threshold is 125 A, equivalent to 10 × In for the 12.5 A release.

How is the ABB 1SDA067658R1 installed?

The 1SDA067658R1 is a fixed four-pole circuit-breaker with front terminals, designed for integration into compatible low-voltage switchboards and distribution assemblies.

Trusted by Electrical Distribution Professionals

ABB SACE Tmax XT moulded-case circuit-breakers combine compact construction, thermomagnetic protection and high short-circuit performance for industrial and commercial low-voltage distribution systems.