1SDA065739R1 ABB T8L 3200 LSI 3200 A 4-Pole Fixed MCCB with Vertical Rear Terminals

1SDA065739R1 ABB T8L 3200 LSI 3200 A 4-Pole Fixed MCCB with Vertical Rear Terminals

ABB T8L 3200 1SDA065739R1 is a 3200 A four-pole fixed SACE Tmax moulded-case circuit breaker with electronic LSI protection, a 690 V rating and vertical rear terminals for high-current power distribution.

SKU: 1SDA065739R1MPN: 1SDA065739R1
Price
List Price £33,326.16 ex VAT
Your Price (ex VAT) Save 25%
£24,994.62 25% OFF
You save £8,331.54 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £24,994.62
Trade pricing is personalised to your account

Manufacturer Lead Time

£24,994.62

Why Choose the ABB T8L 3200 PR331/P-LSI 1SDA065739R1 Circuit Breaker?

The ABB T8L 3200 1SDA065739R1 is a high-current four-pole moulded-case circuit breaker (MCCB) from the ABB SACE Tmax T8 range, designed for demanding industrial power distribution applications. It combines a 3200 A rated uninterrupted current with an electronic trip unit providing LSI protection for large electrical distribution systems.

ABB catalogue information identifies order code 1SDA065739R1 as the T8L 3200 four-pole fixed breaker with vertical rear terminals. The electronic protection arrangement provides long-time, short-time and instantaneous protection, allowing the breaker to protect high-current feeders and distribution circuits against overload and short-circuit conditions.

The breaker is rated at 690 V and uses a fixed installation arrangement with vertical rear connections. Its four-pole construction enables switching and protection of all four conductors in compatible three-phase four-wire systems, while the T8L platform provides the robust construction required for high-power switchboards and industrial distribution assemblies.

Key Advantages

  • High-current ABB SACE Tmax T8L circuit breaker.
  • 3200 A rated uninterrupted current for major power distribution circuits.
  • Four-pole configuration for compatible three-phase four-wire systems.
  • Electronic LSI protection for overload and short-circuit conditions.
  • 690 V rated voltage.
  • Fixed installation construction for permanent switchboard applications.
  • Vertical rear terminals support high-current switchboard and busbar integration.
  • Optional motor-operated mechanism can be incorporated into suitable system designs.

Key Features

  • ABB SACE Tmax T8L 3200 platform.
  • 3200 A rated uninterrupted current (Iu).
  • Four-pole configuration.
  • Electronic protection unit.
  • LSI protection: long-time, short-time and instantaneous.
  • 690 V rated voltage.
  • Fixed breaker construction.
  • Vertical rear terminal arrangement (VR).
  • Bolt-type main-circuit connection.
  • IP20 degree of protection.
  • Toggle operating mechanism.
  • Optional motor drive capability.
  • Designed to IEC requirements.
  • ABB order code 1SDA065739R1.

Electronic LSI Protection for 3200 A Power Distribution

The electronic LSI protection arrangement combines three important protection functions for high-current distribution systems. Long-time protection responds to sustained overload conditions, short-time protection provides a controlled response to high fault currents and can assist protection coordination, while instantaneous protection provides rapid interruption when severe short-circuit conditions occur.

Combined with the T8L 3200 platform, this electronic protection makes the 1SDA065739R1 suitable for major distribution feeders and high-current switchboards where dependable protection and system coordination are important. The four-pole fixed construction and vertical rear terminals are particularly suited to permanent installations using substantial busbar and conductor arrangements.

Typical Applications

  • Main low-voltage power distribution switchboards.
  • High-current industrial distribution systems.
  • Three-phase four-wire power distribution circuits.
  • Large manufacturing and process plants.
  • Transformer secondary distribution.
  • Industrial main incomers and high-current feeders.
  • Infrastructure and commercial power distribution systems.
  • OEM switchgear and high-current electrical distribution assemblies.

Technical Specifications

Series SACE Tmax T8
ABB order code 1SDA065739R1
Product type Moulded-case circuit breaker (MCCB)
Frame / performance level T8L 3200
Protection unit Electronic LSI release
Protection functions Long-time, short-time and instantaneous (LSI)
Rated uninterrupted current (Iu) 3200 A
Rated voltage 690 V
Number of poles 4
Execution Fixed
Terminal arrangement Vertical rear terminals (VR)
Main-circuit connection Bolt connection
Operating element Toggle
Degree of protection IP20
Integrated earth-fault protection No
Motor drive Optional
Standard IEC
EAN 8015644686505
Product group 310511 – Tmax T4–T8

Frequently Asked Questions

What is the ABB T8L 3200 1SDA065739R1?

The ABB 1SDA065739R1 is a 3200 A four-pole fixed SACE Tmax T8L moulded-case circuit breaker with an electronic LSI protection unit and vertical rear terminals for high-current power distribution applications.

What is the current rating of ABB 1SDA065739R1?

The ABB T8L 3200 1SDA065739R1 has a rated uninterrupted current of 3200 A.

What does LSI protection mean on the ABB T8L 3200?

LSI means the electronic protection unit provides long-time, short-time and instantaneous protection functions for overload and short-circuit conditions.

How many poles does the ABB 1SDA065739R1 have?

The 1SDA065739R1 is a four-pole circuit breaker, making it suitable for compatible three-phase four-wire distribution systems where four-pole switching and protection are required.

What does VR mean on the ABB T8L 3200 1SDA065739R1?

VR identifies the breaker's vertical rear terminal arrangement. The 1SDA065739R1 is a fixed breaker with rear vertical connections intended for integration into compatible high-current switchboards and busbar systems.

Trusted ABB Protection for High-Current Distribution

ABB SACE Tmax T8 circuit breakers provide high-current switching and electronic protection for major low-voltage distribution systems, combining robust breaker construction with configurable protection technology for demanding industrial and infrastructure applications.