1SDA062989R1 ABB T7V 1250 PR332/P LI 1250 A 4-Pole MCCB

1SDA062989R1 ABB T7V 1250 PR332/P LI 1250 A 4-Pole MCCB

ABB 1SDA062989R1 is a SACE Tmax T7V 1250 A four-pole fixed moulded case circuit breaker with front terminals, motorisable operation, a PR332/P LI electronic trip unit and 150 kA ultimate short-circuit breaking capacity at 380–415 V AC.

SKU: 1SDA062989R1MPN: 1SDA062989R1
Price
List Price £15,223.89 ex VAT
Your Price (ex VAT) Save 25%
£11,417.92 25% OFF
You save £3,805.97 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £11,417.92
Trade pricing is personalised to your account

Manufacturer Lead Time

£11,417.92

Why Choose the ABB T7V 1250 PR332/P LI 1SDA062989R1 Circuit Breaker?

The ABB 1SDA062989R1 is a high-performance SACE Tmax T7V 1250 moulded case circuit breaker (MCCB) designed for demanding low-voltage power distribution systems. It combines a 1250 A rated current, four-pole construction and the advanced ABB PR332/P LI electronic trip unit for adjustable overload and instantaneous short-circuit protection.

As part of the ABB SACE Tmax T7 series, the T7V 1250 is engineered for installations with very high prospective fault currents. Its V performance level provides an ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC, with breaking performance extending to 200 kA at 220–230 V AC.

The 1SDA062989R1 is a four-pole fixed circuit breaker with front terminals and a motorisable operating mechanism. Its PR332/P LI electronic release combines adjustable long-time overload protection with instantaneous short-circuit protection, making it suitable for high-current distribution systems where dependable fault interruption and configurable electronic protection are required.

Key Advantages

  • High-performance ABB SACE Tmax T7V moulded case circuit breaker.
  • 1250 A rated current for high-current power distribution.
  • Four-pole construction for three-phase systems incorporating a neutral conductor.
  • 150 kA ultimate short-circuit breaking capacity at 380–415 V AC.
  • PR332/P LI electronic trip unit for overload and instantaneous short-circuit protection.
  • Adjustable long-time protection from 0.4–1 × In.
  • Adjustable instantaneous protection from 1.5–15 × In.
  • Fixed configuration with front terminals and motorisable operation.

Key Features

  • ABB SACE Tmax T7V 1250 series.
  • 1250 A rated current.
  • Four-pole (4P) construction.
  • PR332/P LI electronic release.
  • L: adjustable long-time overload protection.
  • I: adjustable instantaneous short-circuit protection.
  • 500–1250 A long-time adjustment range.
  • 1875–18750 A instantaneous adjustment range.
  • Neutral protection settings of OFF / 50% / 100% / 200%.
  • V very-high-breaking-capacity performance level.
  • 150 kA Icu at 380–415 V AC.
  • Rated operational voltage up to 690 V AC.

Very High Breaking Capacity with PR332/P LI Protection

The ABB SACE Tmax T7 platform is engineered for high-current low-voltage installations where dependable interruption of severe prospective fault currents is essential. The T7V 1250 combines a 1250 A current rating with ABB's V performance level, delivering an ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC and up to 200 kA at 220–230 V AC.

The PR332/P LI electronic trip unit provides long-time overload and instantaneous short-circuit protection. Long-time protection can be adjusted from 0.4–1 × In, corresponding to 500–1250 A, while instantaneous protection is adjustable from 1.5–15 × In, corresponding to 1875–18750 A, providing flexibility when coordinating protection in high-current distribution networks.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Four-pole main incomer and feeder protection.
  • High-current electrical switchboards.
  • Transformer and distribution-system protection.
  • Manufacturing and process-industry electrical systems.
  • Infrastructure and large commercial distribution assemblies.
  • Installations with very high prospective short-circuit currents.

Technical Specifications

Series SACE Tmax T7
ABB designation T7V1250PR332/PLIIn=1250A4pFF
Order code 1SDA062989R1
EAN 8015644655389
Product type Moulded case circuit breaker (MCCB)
Frame T7
Performance level V
Rated current (In) 1250 A
Number of poles 4
Trip unit PR332/P LI
Trip-unit technology Electronic
Protection functions Long-time and instantaneous
Long-time protection adjustment 0.4–1 × In (500–1250 A)
Instantaneous protection adjustment 1.5–15 × In (1875–18750 A)
Neutral protection OFF / 50% / 100% / 200%
Rated operational voltage up to 690 V AC
Rated ultimate short-circuit breaking capacity (Icu) at 220–230 V AC 200 kA
Rated ultimate short-circuit breaking capacity (Icu) at 380–415 V AC 150 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 130 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 60 kA
Installation Fixed
Terminal position Front
Operating configuration Motorisable
Dimensions (H × W × D) 268 × 235 × 178 mm
Net weight approx. 11.2 kg
ABB product group 310511-T-Max T4 - T8

Frequently Asked Questions

What is the ABB 1SDA062989R1?

The ABB 1SDA062989R1 is a SACE Tmax T7V 1250 four-pole fixed moulded case circuit breaker rated at 1250 A, with front terminals, a motorisable operating configuration and a PR332/P LI electronic trip unit.

What is the breaking capacity of the ABB T7V 1250 1SDA062989R1?

The ABB T7V 1250 1SDA062989R1 has an ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC, with an Icu of up to 200 kA at 220–230 V AC.

What protection functions does the PR332/P LI trip unit provide?

The PR332/P LI electronic trip unit provides adjustable long-time overload protection and instantaneous short-circuit protection.

What are the protection adjustment ranges of the ABB 1SDA062989R1?

Long-time protection is adjustable from 0.4–1 × In, equivalent to 500–1250 A, while instantaneous protection is adjustable from 1.5–15 × In, equivalent to 1875–18750 A.

Is the ABB 1SDA062989R1 a four-pole fixed circuit breaker?

Yes. The 1SDA062989R1 is a four-pole fixed Tmax T7V circuit breaker with front terminals, designed for high-current three-phase distribution systems incorporating a neutral conductor.

Trusted ABB Power Distribution Protection

ABB SACE Tmax T7 moulded case circuit breakers combine high-current capability, advanced electronic protection and substantial short-circuit breaking performance for dependable protection and coordination in demanding industrial and commercial low-voltage distribution systems.