1SDA062986R1 ABB T7V 1250 PR231/P LS/I 1250 A 4-Pole Moulded Case Circuit Breaker

1SDA062986R1 ABB T7V 1250 PR231/P LS/I 1250 A 4-Pole Moulded Case Circuit Breaker

ABB T7V 1250 PR231/P LS/I 4-pole fixed moulded case circuit breaker with a 1250 A rated current, front terminals, adjustable electronic overload and short-circuit protection, and 150 kA breaking capacity at 380/415 V AC.

SKU: 1SDA062986R1MPN: 1SDA062986R1
Price
List Price £15,248.73 ex VAT
Your Price (ex VAT) Save 25%
£11,436.55 25% OFF
You save £3,812.18 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £11,436.55
Trade pricing is personalised to your account

Manufacturer Lead Time

£11,436.55

Why Choose the ABB T7V 1250 PR231/P LS/I Moulded Case Circuit Breaker?

The ABB T7V 1250 PR231/P LS/I is a high-performance 4-pole moulded case circuit breaker (MCCB) designed for demanding low-voltage power distribution systems. Part of the proven ABB Tmax T7 series, it combines a 1250 A rated current with very high short-circuit breaking capability for industrial, commercial and infrastructure applications.

Equipped with the PR231/P LS/I electronic trip unit, the breaker provides adjustable long-time overload and short-circuit protection. The release has an overload setting adjustable from 0.4–1 × In and short-circuit protection adjustable from 1.5–12 × In, supporting effective coordination with cables, switchgear and downstream electrical equipment.

With an ultimate short-circuit breaking capacity of 150 kA at 380/415 V AC, a 4-pole configuration, fixed mounting and front terminals, ABB order code 1SDA062986R1 is engineered for high-capacity switchboards where reliable interruption of substantial prospective fault currents is required.

Key Advantages

  • High-performance ABB Tmax T7V moulded case circuit breaker.
  • 1250 A rated current for high-capacity power distribution.
  • 150 kA Icu at 380/415 V AC for high prospective fault levels.
  • PR231/P LS/I electronic trip unit for adjustable overload and short-circuit protection.
  • 500–1250 A overload adjustment range.
  • 1875–15000 A short-circuit adjustment range.
  • 4-pole construction for three-phase systems incorporating a neutral conductor.
  • Fixed mounting with front terminals for switchboard integration.

Key Features

  • ABB Tmax T7 series.
  • T7V 1250 performance level.
  • 1250 A rated current.
  • 4-pole construction.
  • PR231/P LS/I electronic protection unit.
  • Adjustable long-time overload protection.
  • Adjustable short-circuit protection.
  • Overload setting: 0.4–1 × In.
  • Short-circuit setting: 1.5–12 × In.
  • Neutral protection settings: OFF / 50% / 100%.
  • 150 kA ultimate short-circuit breaking capacity at 380/415 V AC.
  • Fixed mounting.
  • Front terminals.
  • Designed for high-fault-level low-voltage distribution systems.

Reliable Circuit Protection for Power Distribution

Moulded case circuit breakers such as the ABB Tmax T7 protect low-voltage electrical distribution circuits against overload and short-circuit conditions. The electronic protection unit monitors circuit current and trips the breaker when configured protection thresholds are exceeded, helping safeguard conductors, switchgear and connected electrical equipment.

The T7V 1250 combines a high 1250 A current rating with 150 kA breaking capability at 380/415 V AC and adjustable PR231/P LS/I protection. Its four-pole, fixed front-terminal configuration makes it particularly suitable for high-capacity three-phase distribution systems where dependable protection and high fault-interruption performance are required.

Typical Applications

  • Industrial low-voltage distribution switchboards.
  • Main incomer and feeder circuit protection.
  • High-current four-pole three-phase distribution systems.
  • Commercial and infrastructure electrical distribution.
  • Manufacturing and process-industry electrical systems.
  • Power distribution centres and switchgear assemblies.
  • Installations with high prospective short-circuit currents.

Technical Specifications

Series Tmax T7
ABB order code 1SDA062986R1
Product type Moulded case circuit breaker
Rated current 1250 A
Number of poles 4
Trip unit PR231/P LS/I
Overload adjustment 0.4–1 × In (500–1250 A)
Short-circuit adjustment 1.5–12 × In (1875–15000 A)
Neutral protection settings OFF / 50% / 100%
Ultimate short-circuit breaking capacity (Icu) 200 kA at 220/230 V AC
Mounting type Fixed
Terminal configuration Front terminals
Dimensions (H × W × D) 268 × 235 × 178 mm
Product net weight 11.2 kg
ABB product group 310511-T-Max T4 - T8

Frequently Asked Questions

What is the ABB T7V 1250 PR231/P LS/I 1SDA062986R1?

It is an ABB Tmax T7V 1250 A four-pole moulded case circuit breaker with fixed mounting, front terminals and a PR231/P LS/I electronic protection unit.

What is the rated current of ABB order code 1SDA062986R1?

The ABB T7V 1250 1SDA062986R1 has a rated current of 1250 A.

What is the breaking capacity of the ABB T7V 1250 1SDA062986R1?

The breaker has an ultimate short-circuit breaking capacity of 150 kA at 380/415 V AC, with a voltage-dependent Icu of up to 200 kA at 220/230 V AC.

Which trip unit is fitted to the ABB T7V 1250 1SDA062986R1?

This breaker is equipped with the ABB PR231/P LS/I electronic trip unit, providing adjustable overload and short-circuit protection.

What are the protection adjustment ranges of the ABB 1SDA062986R1?

The overload setting is adjustable from 0.4–1 × In, corresponding to 500–1250 A, while the short-circuit setting is adjustable from 1.5–12 × In, corresponding to 1875–15000 A.

How is the ABB 1SDA062986R1 configured for installation?

ABB order code 1SDA062986R1 is a 4-pole fixed Tmax T7V circuit breaker with front terminals for integration into low-voltage switchboards and power distribution assemblies.

Trusted by Electrical Professionals Worldwide

ABB Tmax moulded case circuit breakers are widely used by electrical engineers, panel builders and industrial operators for dependable circuit protection, power distribution and control in demanding low-voltage installations.