Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA062822R1 T7L 1000 is a 1000 A three-pole fixed moulded case circuit breaker with a PR332/P-LSI electronic trip unit and 120 kA breaking capacity at 380–415 V AC for high-current low-voltage power distribution.
£9,024.97
The ABB 1SDA062822R1, extended product type T7L 1000 PR332/P LSI In=1000A 3p F F M, is a high-performance moulded case circuit breaker (MCCB) designed for protection and switching of high-current low-voltage electrical distribution systems. As part of the established ABB SACE Tmax T7 series, it combines a 1000 A rated current with an advanced PR332/P-LSI electronic trip unit for comprehensive overload and short-circuit protection.
This T7L configuration uses a fixed three-pole breaker body with front terminals and a stored-energy operating mechanism, making it suitable for demanding industrial switchboards and power distribution assemblies. The PR332/P-LSI electronic release provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection, allowing protection characteristics to be coordinated with the requirements of the electrical installation.
With a rated uninterrupted current of 1000 A and a rated ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC, the T7L 1000 is engineered for installations where high fault-current performance is required. Its robust fixed construction, electronic protection and front-terminal arrangement make it well suited to industrial plants, infrastructure and large low-voltage power distribution systems.
Moulded case circuit breakers such as the ABB Tmax T7L protect electrical distribution systems against excessive current caused by overloads and short circuits. By interrupting dangerous fault currents rapidly, the breaker helps protect cables, switchgear and connected equipment while supporting the safety and availability of the electrical installation.
The PR332/P-LSI electronic trip unit provides adjustable long-time, short-time and instantaneous protection, enabling the breaker characteristics to be coordinated with downstream and upstream protection devices. Combined with the high breaking capacity of the T7L platform, this makes the 1SDA062822R1 particularly suitable for complex industrial distribution networks where selective and configurable circuit protection is required.
| Series | SACE Tmax T7 |
|---|---|
| ABB product group | 310511-T-Max T4 - T8 |
| Order code | 1SDA062822R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Breaker type | T7L 1000 |
| Rated current | 1000 A |
| Rated uninterrupted current (Iu) | 1000 A |
| Number of poles | 3 |
| Trip unit | PR332/P-LSI electronic release |
| Protection functions | Long-time overload, short-time delayed and instantaneous short-circuit protection |
| Overload release setting | 400–1000 A |
| Short-time delayed short-circuit release setting | 600–10000 A |
| Instantaneous short-circuit release setting | 1500–15000 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage | 1000 V |
| Rated impulse withstand voltage | 8 kV |
| Ultimate breaking capacity (Icu) at 220–230 V AC | 200 kA |
| Ultimate breaking capacity (Icu) at 380–415 V AC | 120 kA |
| Ultimate breaking capacity (Icu) at 440 V AC | 100 kA |
| Ultimate breaking capacity (Icu) at 500 V AC | 85 kA |
| Ultimate breaking capacity (Icu) at 690 V AC | 50 kA |
| Rated short-time withstand current (Icw) | 20 kA for 1 s |
| Protection rating | IP20 |
| Installation version | Fixed |
| Terminal position | Front |
| Operating mechanism | Stored-energy mechanism |
| Motor drive | Optional |
| Power loss at rated operating conditions | 30 W per pole |
| Mechanical durability | 10,000 cycles |
| Electrical durability | 2,000 cycles |
| Dimensions (H × W × D) | 268 × 210 × 178 mm |
| Net weight | 11 kg |
The ABB 1SDA062822R1 is a 1000 A moulded case circuit breaker used to protect high-current low-voltage electrical distribution circuits against overloads and short circuits.
The circuit breaker has a rated uninterrupted current of 1000 A, with an adjustable overload release setting from 400–1000 A.
The T7L configuration provides a rated ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC.
The breaker is fitted with an ABB PR332/P-LSI electronic trip unit, providing long-time overload, short-time delayed and instantaneous short-circuit protection.
This model is a fixed three-pole circuit breaker with front terminals, designed for installation in low-voltage switchboards and power distribution assemblies.
ABB SACE Tmax moulded case circuit breakers are widely used in industrial, commercial and infrastructure power distribution systems where dependable circuit protection, high breaking capacity and flexible electronic protection are required.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.