1SDA060591R1 ABB Tmax T6S 1000A 4-Pole Breaking Part

1SDA060591R1 ABB Tmax T6S 1000A 4-Pole Breaking Part

ABB 1SDA060591R1 is a Tmax T6S 1000 A four-pole fixed breaking part with front terminals and 50 kA ultimate breaking capacity at 415 V AC for configurable low-voltage circuit protection.

SKU: 1SDA060591R1MPN: 1SDA060591R1
Price
List Price £4,468.75 ex VAT
Your Price (ex VAT) Save 25%
£3,351.56 25% OFF
You save £1,117.19 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,351.56
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,351.56

Why Choose the ABB 1SDA060591R1 Tmax T6S 1000 Breaking Part?

The ABB 1SDA060591R1 is a Tmax T6S 1000 breaking part designed for high-current low-voltage circuit breaker applications. Configured with four poles, fixed mounting and front terminals, this genuine ABB breaking unit provides the main switching and current-carrying assembly for a compatible ABB SACE Tmax T6 protection configuration.

As part of the ABB SACE Tmax T6 series, the T6S 1000 platform is designed for demanding industrial and commercial power distribution. The breaking part has a rated uninterrupted current of 1000 A and provides an ultimate short-circuit breaking capacity of 50 kA at 415 V AC, making it suitable for substantial distribution feeders and switchboard applications.

The 1SDA060591R1 is supplied as a four-pole fixed breaking part with front terminals. It is the breaker body rather than a complete protection-equipped circuit breaker and is intended to be combined with a compatible ABB Tmax T6 electronic trip unit and any required accessories to create the required protection configuration.

Key Advantages

  • Genuine ABB Tmax T6S 1000 breaking part.
  • 1000 A rated uninterrupted current for high-current distribution applications.
  • Four-pole configuration suitable for systems requiring switching of the neutral conductor.
  • 50 kA ultimate breaking capacity at 415 V AC.
  • Fixed installation with front terminals for switchboard integration.
  • Allows a compatible ABB Tmax T6 trip unit to be selected separately for the required protection functions.

Key Features

  • ABB SACE Tmax T6S 1000 breaking unit.
  • 1000 A rated uninterrupted current.
  • Four-pole configuration.
  • 50 kA Icu at 415 V AC.
  • Fixed breaker construction.
  • Front main-circuit terminals.
  • Designed to accept a compatible ABB Tmax T6 electronic trip unit.
  • Suitable for high-current industrial power distribution.
  • Part of the modular ABB Tmax T6 circuit breaker system.
  • ABB order code 1SDA060591R1.

Flexible High-Current Circuit Breaker Configuration

A circuit breaker breaking part contains the primary current-carrying contacts and interruption mechanism used to switch normal load current and interrupt fault current. In ABB's modular Tmax T6 system, the breaking unit can be combined with the appropriate compatible trip unit to provide the protection characteristics required by the electrical installation.

The ABB 1SDA060591R1 combines a 1000 A four-pole T6S breaking unit with fixed mounting and front terminals. Its 50 kA breaking capacity at 415 V AC makes it suitable for demanding distribution systems, while the separate trip-unit architecture provides flexibility when configuring overload, short-circuit and other protection functions.

Typical Applications

  • Industrial low-voltage power distribution.
  • Main and sub-main electrical feeders.
  • Four-pole distribution systems requiring neutral switching.
  • Manufacturing and process plant switchboards.
  • Commercial and infrastructure distribution panels.
  • Custom ABB Tmax T6 circuit breaker assemblies.

Technical Specifications

Series SACE Tmax T6
Order code 1SDA060591R1
Product type Moulded-case circuit breaker breaking part
Breaker designation T6S 1000
Rated uninterrupted current (Iu) 1000 A
Number of poles 4
Ultimate breaking capacity (Icu) at 415 V AC 50 kA
Mounting type Fixed
Main connection position Front
Configuration Breaking part / breaker body
Trip unit Selected separately
Application Low-voltage circuit protection and switching
ABB product group 310511-T-Max T4 - T8

Frequently Asked Questions

What is the ABB 1SDA060591R1?

The ABB 1SDA060591R1 is a Tmax T6S 1000 four-pole breaking part with fixed mounting and front terminals, designed as the main breaker body for a compatible ABB Tmax T6 protection configuration.

What is the current rating of the ABB 1SDA060591R1?

The T6S 1000 breaking part has a rated uninterrupted current of 1000 A.

What is the breaking capacity of the ABB 1SDA060591R1?

The ABB Tmax T6S 1000 has an ultimate short-circuit breaking capacity of 50 kA at 415 V AC.

How many poles does the ABB 1SDA060591R1 have?

The 1SDA060591R1 is a four-pole breaking unit, making it suitable for compatible distribution systems where four-pole switching is required.

Does the ABB 1SDA060591R1 include a trip unit?

The 1SDA060591R1 is specified as a breaking part. A compatible ABB Tmax T6 trip unit is selected separately according to the protection functions and current settings required by the installation.

Trusted ABB Circuit Protection

ABB SACE Tmax moulded-case circuit breaker components provide a modular approach to low-voltage protection, allowing compatible breaking units, electronic trip units and accessories to be combined for dependable industrial and commercial power distribution.