1SDA060352R1 ABB PR221DS-I In=630 T6 630 3P Electronic Trip Unit

1SDA060352R1 ABB PR221DS-I In=630 T6 630 3P Electronic Trip Unit

ABB 1SDA060352R1 PR221DS-I is a 630 A three-pole solid-state electronic trip unit providing adjustable instantaneous short-circuit protection for compatible SACE Tmax T6 630 circuit breakers.

SKU: 1SDA060352R1MPN: 1SDA060352R1
Price
List Price £1,724.49 ex VAT
Your Price (ex VAT) Save 25%
£1,293.37 25% OFF
You save £431.12 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,293.37
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,293.37

Why Choose the ABB PR221DS-I In=630 T6 630 3P 1SDA060352R1 Trip Unit?

The ABB PR221DS-I In=630 T6 630 3P 1SDA060352R1 is a three-pole solid-state electronic trip unit designed for compatible ABB SACE Tmax T6 630 moulded case circuit breakers. With a rated current of 630 A, this PR221DS-I release provides instantaneous short-circuit protection for demanding low-voltage industrial power distribution applications.

As part of the ABB SACE Tmax T6 protection system, the PR221DS-I uses electronic current sensing to initiate circuit-breaker tripping when the configured instantaneous fault-current threshold is exceeded. The I-only protection characteristic makes this version suitable for applications where instantaneous short-circuit protection is required without the long-time overload function provided by other PR221DS variants.

This release is specifically configured for T6 630 three-pole circuit breakers and has a rated current of 630 A. Its undelayed short-circuit release is adjustable from 630–6300 A, corresponding to 1–10 × In, providing flexibility when coordinating instantaneous protection with the characteristics of the electrical installation.

Key Advantages

  • Solid-state PR221DS-I electronic protection release for compatible ABB SACE Tmax T6 circuit breakers.
  • 630 A rated current for high-current industrial applications.
  • Instantaneous short-circuit protection for rapid response to high fault currents.
  • Adjustable instantaneous trip threshold from 1–10 × In.
  • Undelayed short-circuit adjustment range of 630–6300 A.
  • Three-pole AC configuration designed for compatible T6 630 circuit breakers.

Key Features

  • ABB PR221DS-I electronic trip unit.
  • I protection function for instantaneous short-circuit protection.
  • 630 A rated current.
  • Designed for ABB SACE Tmax T6 630 circuit breakers.
  • Three-pole configuration.
  • Designed for AC circuit-breaker applications.
  • Instantaneous short-circuit setting of 1–10 × In.
  • Undelayed short-circuit adjustment range of 630–6300 A.
  • Solid-state electronic protection technology.
  • Suitable for compatible power circuit breakers.

Instantaneous Electronic Protection for Tmax T6 Circuit Breakers

Electronic trip units such as the ABB PR221DS-I monitor current through a compatible circuit breaker and initiate tripping when the selected instantaneous short-circuit threshold is exceeded. This provides rapid interruption of high fault currents and helps protect electrical equipment and distribution circuits against the damaging thermal and mechanical effects of short circuits.

For this 630 A T6 configuration, the instantaneous protection threshold can be adjusted across a broad 630–6300 A range. This allows engineers to coordinate the trip characteristic with the requirements of the installation while using the proven modular architecture of the ABB SACE Tmax T6 circuit-breaker platform.

Typical Applications

  • Compatible ABB SACE Tmax T6 630 moulded case circuit breakers.
  • Industrial low-voltage power distribution systems.
  • Electrical switchboards and distribution panels.
  • High-current industrial feeder circuits.
  • Manufacturing and process plant electrical systems.
  • Applications requiring adjustable instantaneous short-circuit protection.

Technical Specifications

Series SACE Tmax T6
ABB order code 1SDA060352R1
Product group 310511-T-Max T4 - T8
Product type Solid-state electronic trip unit / release
Trip unit PR221DS-I
Compatible circuit breaker frame T6
Compatible breaker rating T6 630
Rated current (In) 630 A
Number of poles 3
Application AC power circuit breaker protection
Protection function I (instantaneous short-circuit)
Instantaneous short-circuit protection setting 1–10 × In
Undelayed short-circuit release adjustment range 630–6300 A
Suitable for power circuit breakers Yes
Suitable for load-break switches No
Suitable for motor protection switches No
EAN 8015644628208

Frequently Asked Questions

What is the ABB 1SDA060352R1?

The ABB 1SDA060352R1 is a PR221DS-I three-pole solid-state electronic trip unit rated at 630 A for compatible ABB SACE Tmax T6 630 circuit breakers.

What protection does the PR221DS-I provide?

The PR221DS-I provides instantaneous short-circuit protection, tripping the compatible circuit breaker when current exceeds the selected undelayed fault-current threshold.

What is the rated current of the ABB 1SDA060352R1?

The electronic trip unit has a rated current of 630 A and is designed for compatible T6 630 three-pole circuit breakers.

What is the instantaneous short-circuit adjustment range?

The undelayed short-circuit release is adjustable from 630–6300 A, corresponding to approximately 1–10 × In for this 630 A trip unit.

Which circuit breakers are compatible with the ABB 1SDA060352R1?

The 1SDA060352R1 is designed as a three-pole PR221DS-I electronic release for compatible ABB SACE Tmax T6 630 circuit breakers.

Trusted Electronic Circuit Protection from ABB

ABB SACE Tmax electronic trip units provide configurable protection for industrial electrical distribution systems, allowing compatible moulded case circuit breakers to respond rapidly to fault currents while supporting effective protection coordination.