1SDA059316R1 ABB E2S 1000 PR122/P-LI 1000A 4P Withdrawable Air Circuit Breaker

1SDA059316R1 ABB E2S 1000 PR122/P-LI 1000A 4P Withdrawable Air Circuit Breaker

ABB 1SDA059316R1 SACE Emax E2S 1000 four-pole withdrawable air circuit breaker moving part rated at 1000 A with a PR122/P-LI electronic release and 85 kA breaking capacity at 400/415 V AC.

SKU: 1SDA059316R1MPN: 1SDA059316R1
Price
List Price £13,353.59 ex VAT
Your Price (ex VAT) Save 25%
£10,015.19 25% OFF
You save £3,338.40 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £10,015.19
Trade pricing is personalised to your account

Manufacturer Lead Time

£10,015.19

Why Choose the ABB E2S 1000 PR122/P-LI 1000A 4P Withdrawable Air Circuit Breaker?

The ABB 1SDA059316R1 is a high-performance SACE Emax E2S air circuit breaker moving part designed for protection and switching in demanding low-voltage power distribution systems. This configuration combines a 1000 A rated current, four-pole construction and withdrawable design with the advanced PR122/P-LI electronic overcurrent release.

Part of the ABB SACE Emax family, the E2S 1000 is engineered for industrial, commercial and infrastructure distribution systems requiring dependable protection and high short-circuit performance. The PR122/P-LI release provides long-time overload and instantaneous short-circuit protection, helping safeguard conductors, switchgear and connected equipment against damaging overcurrent conditions.

This model is the four-pole withdrawable moving part (W MP) version of the E2S 1000. It has a rated uninterrupted current of 1000 A, rated operational voltage up to 690 V AC and a rated ultimate short-circuit breaking capacity of 85 kA at 400/415 V AC, making it suitable for high-current switchboards where strong fault-clearing capability and convenient breaker isolation are required.

Key Advantages

  • High-performance 1000 A SACE Emax air circuit breaker moving part.
  • PR122/P-LI electronic trip unit provides long-time overload and instantaneous short-circuit protection.
  • 85 kA ultimate breaking capacity at 400/415 V AC for demanding fault conditions.
  • Four-pole construction supports three-phase systems requiring neutral switching.
  • Withdrawable construction simplifies isolation, inspection and maintenance.
  • 65 kA short-time withstand current for 1 s supports robust distribution-system coordination.
  • Fitted with four auxiliary contacts and open/closed position indication.

Key Features

  • ABB SACE Emax E2S frame.
  • 1000 A rated current.
  • Four-pole construction.
  • Withdrawable moving part (W MP) configuration.
  • PR122/P-LI R1000 electronic overcurrent release.
  • Long-time overload protection.
  • Instantaneous short-circuit protection.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 85 kA Icu at 400/415 V AC.
  • 65 kA Icu at 690 V AC.
  • 65 kA short-time withstand current for 1 s.
  • Four auxiliary contacts with open/closed position indication.

Reliable LI Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax E2S provide switching and protection at the heart of low-voltage power distribution systems. The electronic trip unit monitors circuit current and initiates interruption when configured protection thresholds are exceeded, helping prevent overloads and severe short circuits from damaging cables, switchgear and connected equipment.

The PR122/P-LI release fitted to this E2S 1000 combines long-time overload protection with instantaneous short-circuit protection. Together with the E2S frame's 85 kA breaking capacity at 400/415 V AC, four-pole construction and withdrawable format, this configuration provides dependable protection while facilitating isolation and maintenance in important industrial and commercial switchboards.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Main incoming circuit protection.
  • High-current feeder protection.
  • Four-pole systems requiring neutral switching.
  • Manufacturing and process plant switchgear.
  • Commercial and infrastructure electrical distribution.
  • Transformer secondary and generator distribution systems.

Technical Specifications

Series SACE Emax
ABB order code 1SDA059316R1
Product group 310513-New Emax
Product type Air circuit breaker moving part
Frame / sub-type E2S
Short-circuit performance level S
Rated current (In) 1000 A
Rated uninterrupted current (Iu) 1000 A
Rated operational current (Ie) 1000 A
Number of poles 4
Version Withdrawable (W)
Configuration Moving part (MP)
Trip unit PR122/P-LI R1000
Release type Electronic
Protection functions Long-time and instantaneous
Current type AC
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 400/415 V AC 85 kA
Rated service short-circuit breaking capacity (Ics) at 400/415 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 65 kA
Rated service short-circuit breaking capacity (Ics) at 690 V AC 65 kA
Rated short-time withstand current (Icw), 1 s 65 kA
Rated short-time withstand current (Icw), 3 s 50 kA
Terminal connection type Withdrawable circuit breaker
Auxiliary contacts 4
Position indication Open / closed
Power loss 83.2 W
Electrical durability 15,000 cycles
Mechanical durability 25,000 cycles
Dimensions (W × H × D) 414 × 461 × 396.5 mm
Product net weight 61 kg
EAN 8015644616779
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA059316R1?

The ABB 1SDA059316R1 is a SACE Emax E2S 1000 four-pole withdrawable air circuit breaker moving part rated at 1000 A and equipped with a PR122/P-LI R1000 electronic overcurrent release.

What protection functions does the PR122/P-LI trip unit provide?

The PR122/P-LI electronic release provides long-time overload protection and instantaneous short-circuit protection.

What is the breaking capacity of the ABB E2S 1000?

This E2S configuration has a rated ultimate short-circuit breaking capacity of 85 kA at 400/415 V AC and 65 kA at 690 V AC.

Is ABB 1SDA059316R1 fixed or withdrawable?

ABB 1SDA059316R1 is the withdrawable moving part (W MP) version of the E2S 1000, designed for use with a compatible ABB SACE Emax E2 fixed part.

Where is the ABB E2S 1000 PR122/P-LI typically used?

It is typically used in industrial, commercial and infrastructure low-voltage switchboards for main incomer and feeder protection where high short-circuit performance, four-pole switching and convenient breaker isolation are required.

Trusted ABB Protection for Power Distribution

ABB SACE Emax air circuit breakers are engineered for dependable switching and circuit protection in demanding low-voltage power distribution systems, combining high short-circuit performance with electronic protection and service-friendly withdrawable configurations.