ABB 1SDA059315R1 is a SACE Emax E2S 1000 A four-pole fixed air circuit breaker with rear horizontal terminals, a PR122/P-LI R1000 electronic overcurrent release, LI protection and four auxiliary contacts for open/closed position indication.
£9,831.02
The ABB E2S1000 PR122/P-LI, order code 1SDA059315R1, is a high-performance SACE Emax air circuit breaker designed for protection and switching in demanding low-voltage electrical distribution systems. Part of the proven ABB SACE Emax E2S series, this four-pole fixed circuit breaker has a rated current of 1000 A and incorporates the PR122/P-LI R1000 electronic overcurrent release.
The PR122/P-LI protection unit provides long-time overload and instantaneous short-circuit protection, helping safeguard cables, busbars and connected equipment against damaging overcurrent conditions. The E2S performance level provides an ultimate short-circuit breaking capacity of 85 kA at 400–415 V AC and 65 kA at 690 V AC, making this breaker suitable for demanding industrial and commercial distribution systems.
This version is a four-pole fixed circuit breaker with rear horizontal terminals. It is fitted with four auxiliary contacts arranged as 2 NO + 2 NC and provides circuit-breaker open/closed position indication, supporting status monitoring and integration into industrial switchboards and power distribution assemblies.
ABB SACE Emax air circuit breakers are engineered to provide dependable switching and protection for high-current low-voltage distribution circuits. The PR122/P electronic trip unit monitors circuit current and initiates breaker operation when configured protection thresholds are exceeded, helping protect cables, busbars and connected electrical equipment.
The LI protection configuration combines long-time overload protection with instantaneous short-circuit protection. Together with the E2S short-circuit performance level, four-pole configuration and fixed construction, the E2S1000 provides a robust solution for switchboards requiring dependable electronic protection and strong fault-clearing capability.
| Series | SACE Emax E2S |
|---|---|
| ABB order code | 1SDA059315R1 |
| ABB product group | 310513-New Emax |
| Product type | Air circuit breaker |
| Rated current | 1000 A |
| Rated uninterrupted current Iu | 1000 A |
| Rated operational current Ie | 1000 A |
| Number of poles | 4 |
| Trip unit | PR122/P-LI R1000 |
| Release type | Electronic |
| Protection functions | L, I |
| Execution | Fixed |
| Terminal arrangement | Rear horizontal |
| Current type | AC |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage | 1000 V |
| Rated impulse withstand voltage | 12 kV |
| Rated ultimate short-circuit breaking capacity | 85 kA at 400–415 V AC; 65 kA at 690 V AC |
| Rated service short-circuit breaking capacity | 85 kA at 400–415 V AC; 65 kA at 690 V AC |
| Rated short-time withstand current | 65 kA for 1 s; 50 kA for 3 s |
| Overload release current setting | 400–1000 A |
| Instantaneous short-circuit release adjustment range | 1500–15000 A |
| Short-circuit performance level | S |
| Protection degree | IP2X |
| Power loss | 44.8 W |
| Mechanical durability | 25,000 cycles |
| Electrical durability | 15,000 cycles |
| Auxiliary contacts | 4 |
| Auxiliary contact configuration | 2 NO + 2 NC |
| Position indication | Circuit breaker open/closed |
| Motor drive | Optional |
| Trip indication | Yes |
| Product dimensions (W × H × D) | 386 × 418 × 302 mm |
| Net weight | 56 kg |
| EAN | 8015644616762 |
| Customs tariff number | 85362090 |
| Standard | IEC |
The ABB 1SDA059315R1 is a four-pole 1000 A SACE Emax E2S fixed air circuit breaker with rear horizontal terminals and a PR122/P-LI R1000 electronic overcurrent release.
The E2S1000 has a rated uninterrupted current of 1000 A and is designed for demanding low-voltage power distribution applications.
The PR122/P-LI provides long-time overload and instantaneous short-circuit protection, represented by the L and I protection functions.
The 1SDA059315R1 is a fixed four-pole circuit breaker equipped with rear horizontal main terminals.
The E2S1000 has a rated ultimate short-circuit breaking capacity of 85 kA at 400–415 V AC and 65 kA at 690 V AC.
ABB SACE Emax air circuit breakers provide dependable protection and switching for demanding low-voltage power distribution systems, combining electronic overcurrent protection with high short-circuit performance and robust switchboard integration.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.