ABB 1SDA059302R1 SACE Emax E2S 1000 three-pole withdrawable air circuit breaker moving part rated at 1000 A with a PR121/P-LI electronic release and 85 kA breaking capacity at 400/415 V AC.
£7,754.99
The ABB 1SDA059302R1 is a high-performance SACE Emax E2S air circuit breaker moving part designed for protection and switching in demanding low-voltage power distribution systems. This configuration combines a 1000 A rated current, three-pole construction and withdrawable design with the PR121/P-LI electronic overcurrent release.
Part of the ABB SACE Emax family, the E2S 1000 is engineered for industrial, commercial and infrastructure distribution systems requiring high short-circuit performance and dependable circuit protection. The PR121/P-LI release provides long-time overload and instantaneous short-circuit protection, helping protect conductors, switchgear and connected equipment against damaging overcurrent conditions.
This model is the three-pole withdrawable moving part (W MP) version of the E2S 1000. It has a rated uninterrupted current of 1000 A, rated operational voltage up to 690 V AC and an ultimate short-circuit breaking capacity of 85 kA at 400/415 V AC, making it suitable for high-current switchboards where strong fault-clearing capability and convenient breaker isolation are required.
Air circuit breakers such as the ABB SACE Emax E2S provide switching and protection at the heart of low-voltage power distribution systems. The electronic trip unit monitors circuit current and initiates interruption when configured protection thresholds are exceeded, helping prevent overloads and severe short circuits from damaging cables, switchgear and connected equipment.
The PR121/P-LI release fitted to this E2S 1000 combines long-time overload protection with instantaneous short-circuit protection. Together with the E2S frame's 85 kA breaking capacity at 400/415 V AC and withdrawable construction, this configuration provides dependable protection while facilitating isolation and maintenance in important industrial and commercial switchboards.
| Series | SACE Emax |
|---|---|
| ABB order code | 1SDA059302R1 |
| Product type | Air circuit breaker moving part |
| Frame / sub-type | E2 |
| Short-circuit performance level | S |
| Rated current (In) | 1000 A |
| Rated uninterrupted current (Iu) | 1000 A |
| Rated operational current (Ie) | 1000 A |
| Number of poles | 3 |
| Version | Withdrawable (W) |
| Configuration | Moving part (MP) |
| Trip unit | PR121/P-LI electronic release |
| Release type | Electronic |
| Protection functions | Long-time and instantaneous |
| Instantaneous short-circuit adjustment range | 1500–15000 A |
| Current type | AC |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) at 400/415 V AC | 85 kA |
| Rated service short-circuit breaking capacity (Ics) at 400/415 V AC | 85 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 65 kA |
| Rated service short-circuit breaking capacity (Ics) at 690 V AC | 65 kA |
| Rated short-time withstand current (Icw), 1 s | 65 kA |
| Rated short-time withstand current (Icw), 3 s | 50 kA |
| Auxiliary contacts | 4 |
| Position indication | Open / closed |
| Protection rating | IP2X |
| Motor drive | Optional |
| Power loss | 83.2 W |
| Electrical durability | 15,000 cycles |
| Mechanical durability | 25,000 cycles |
| Dimensions (W × H × D) | 324 × 461 × 396.5 mm |
| Product net weight | 49 kg |
| EAN | 8015644616632 |
| Standard | IEC |
The ABB 1SDA059302R1 is a SACE Emax E2S 1000 three-pole withdrawable air circuit breaker moving part rated at 1000 A and equipped with a PR121/P-LI electronic overcurrent release.
The PR121/P-LI electronic release provides long-time overload protection and instantaneous short-circuit protection.
This E2S configuration has a rated ultimate short-circuit breaking capacity of 85 kA at 400/415 V AC and 65 kA at 690 V AC.
ABB 1SDA059302R1 is the withdrawable moving part (W MP) version of the E2S 1000 and is designed for use with a compatible ABB SACE Emax E2 fixed part.
It is typically used in industrial, commercial and infrastructure low-voltage switchboards for main incomer and feeder protection where high short-circuit breaking performance is required.
ABB SACE Emax air circuit breakers are engineered for dependable switching and circuit protection in demanding low-voltage power distribution systems, combining high short-circuit performance with electronic protection and service-friendly withdrawable configurations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.