1SDA059177R1 ABB E1B 1000 PR121/P-LSIG 3P F HR Air Circuit Breaker

1SDA059177R1 ABB E1B 1000 PR121/P-LSIG 3P F HR Air Circuit Breaker

ABB 1SDA059177R1 E1B 1000 is a 1000 A three-pole fixed SACE Emax air circuit breaker with horizontal rear terminals and a PR121/P-LSIG electronic release providing long-time, short-time, instantaneous and earth-fault protection.

SKU: 1SDA059177R1MPN: 1SDA059177R1
Price
List Price £11,292.09 ex VAT
Your Price (ex VAT) Save 25%
£8,469.07 25% OFF
You save £2,823.02 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,469.07
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,469.07

Why Choose the ABB E1B 1000 PR121/P-LSIG 3P F HR Air Circuit Breaker?

The ABB E1B 1000 PR121/P-LSIG 3P F HR, order code 1SDA059177R1, is a three-pole fixed SACE Emax air circuit breaker rated at 1000 A. Designed for low-voltage power distribution, it combines the compact E1B frame with ABB's PR121/P-LSIG electronic overcurrent release and rear horizontal main terminals.

This configuration is a fixed (F) circuit breaker with horizontal rear (HR) connections. Its PR121/P release uses an R1000 rating and provides long-time (L), short-time (S), instantaneous (I) and earth-fault/ground-fault (G) protection, giving the breaker comprehensive electronic protection against common overcurrent and earth-fault conditions.

The 1SDA059177R1 also incorporates four auxiliary contacts and open/closed position indication. With a rated uninterrupted current of 1000 A and a rated ultimate short-circuit breaking capacity of 42 kA at 400 V AC, it is suited to industrial, commercial and infrastructure distribution systems requiring fixed air circuit-breaker protection.

Key Advantages

  • 1000 A rated uninterrupted current for substantial low-voltage distribution loads.
  • PR121/P-LSIG electronic trip unit providing four key protection functions.
  • Integrated earth-fault/ground-fault protection in addition to overload and short-circuit protection.
  • 42 kA ultimate short-circuit breaking capacity at 400 V AC.
  • Three-pole fixed construction for permanent switchboard installations.
  • Horizontal rear terminals for busbar-connected switchgear arrangements.
  • Four auxiliary contacts for status and control integration.
  • Open/closed position indication for clear breaker-state feedback.

Key Features

  • ABB SACE Emax E1B series.
  • 1000 A rated uninterrupted current.
  • 3-pole configuration.
  • Fixed (F) installation.
  • Horizontal rear (HR) main terminals.
  • PR121/P electronic overcurrent release.
  • R1000 release rating.
  • LSIG protection functions.
  • Long-time overload protection (L).
  • Short-time short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Earth-fault/ground-fault protection (G).
  • Four auxiliary contacts.
  • Open/closed position indication.

PR121/P-LSIG Electronic Protection

The PR121/P-LSIG release provides a comprehensive protection package for low-voltage distribution systems. Long-time protection responds to sustained overloads, short-time protection provides controlled response to short-circuit currents, instantaneous protection reacts rapidly to severe short circuits, and the G function provides protection against earth-fault or ground-fault current.

Combined with the 1000 A E1B three-pole fixed breaker, these functions make the 1SDA059177R1 suitable for installations where coordinated electronic protection and earth-fault detection are required from the main switching and protection device.

Typical Applications

  • Industrial low-voltage main distribution boards.
  • 1000 A power distribution feeders.
  • Three-phase fixed switchboard installations.
  • Systems requiring integrated earth-fault protection.
  • Manufacturing and process facilities.
  • Commercial and infrastructure power distribution.
  • Transformer and generator distribution systems.

Technical Specifications

Series SACE Emax
ABB order code 1SDA059177R1
Product group 310513-New Emax
Product type Air circuit breaker
Frame E1
Performance level B
Rated uninterrupted current (Iu) 1000 A
Number of poles 3P
Installation Fixed (F)
Main terminal connection Horizontal rear (HR)
Trip unit PR121/P
Release rating R1000 / 1000 A
Protection functions LSIG
Overload setting range 400–1000 A
Short-time short-circuit setting range 1000–10000 A
Instantaneous short-circuit setting range 1500–15000 A
Ultimate short-circuit breaking capacity (Icu) at 400 V AC, 50 Hz 42 kA
Integrated earth-fault protection Yes
Auxiliary contacts 4 (2 NO + 2 NC)
Position indication Open/closed
Motor operator Optional
Degree of protection IP20
Product net weight 50 kg
EAN 8015644615383
Customs tariff number 85362090

Frequently Asked Questions

What is the ABB 1SDA059177R1?

It is a 1000 A three-pole fixed ABB SACE Emax E1B air circuit breaker with horizontal rear terminals and a PR121/P-LSIG electronic overcurrent release.

What protection does the PR121/P-LSIG trip unit provide?

The LSIG designation represents long-time (L), short-time (S), instantaneous (I) and earth-fault/ground-fault (G) protection.

What is the breaking capacity of the ABB 1SDA059177R1?

The E1B configuration has a rated ultimate short-circuit breaking capacity of 42 kA at 400 V AC, 50 Hz.

What does 3P F HR mean on the ABB E1B 1000?

3P identifies the three-pole configuration, F denotes fixed installation and HR identifies the horizontal rear main-terminal arrangement.

Does the ABB 1SDA059177R1 include auxiliary contacts?

Yes. This configuration includes four auxiliary contacts, comprising two normally open and two normally closed contacts, together with open/closed position indication.

Trusted ABB SACE Emax Circuit Protection

ABB SACE Emax air circuit breakers combine high-current switching with configurable electronic protection, helping industrial, commercial and infrastructure installations protect and control critical low-voltage power distribution systems.