ABB 1SDA057281R1 E2B-A 1600 PR121/P-LSIG is a 1600 A three-pole SACE Emax air circuit breaker with an R1600 PR121/P electronic release providing LSIG overcurrent and earth-fault protection.

SKU: 1SDA057281R1MPN: 1SDA057281R1
Price
List Price £12,443.60 ex VAT
Your Price (ex VAT) Save 25%
£9,332.70 25% OFF
You save £3,110.90 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,332.70
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,332.70

Why Choose the ABB E2B-A 1600 PR121/P-LSIG 1600A 3-Pole Air Circuit Breaker?

The ABB E2B-A 1600 PR121/P-LSIG, order code 1SDA057281R1, is a SACE Emax air circuit breaker designed for protection and switching in demanding low-voltage power distribution systems. This E2B-A configuration combines a 1600 A rated current and three-pole construction with ABB's PR121/P electronic overcurrent protection technology.

The breaker is equipped with a PR121/P-LSIG R1600 electronic overcurrent release, providing long-time, short-time, instantaneous and earth-fault protection functions. This comprehensive LSIG arrangement helps protect distribution circuits against sustained overloads, short-circuit faults and earth faults while supporting coordinated protection within industrial and infrastructure electrical networks.

With its 1600 A current rating and three-pole configuration, the E2B-A 1600 PR121/P-LSIG is engineered for substantial three-phase incomer and feeder duties. Its electronic protection system provides a versatile solution for switchboards where dependable overload, short-circuit and earth-fault protection are required.

Key Advantages

  • 1600 A SACE Emax air circuit breaker for substantial low-voltage distribution duties.
  • Three-pole construction suited to three-phase electrical distribution systems.
  • PR121/P-LSIG electronic release provides comprehensive overcurrent and earth-fault protection.
  • Long-time and short-time protection supports overload protection and selective fault coordination.
  • Instantaneous protection provides rapid response to severe short-circuit conditions.
  • Earth-fault protection adds protection against ground-related fault conditions.

Key Features

  • ABB SACE Emax E2B-A series.
  • 1600 A rated current.
  • Three-pole configuration.
  • PR121/P electronic overcurrent release.
  • LSIG protection functions: long-time, short-time, instantaneous and earth-fault.
  • R1600 release rating.
  • Designed for substantial three-phase low-voltage distribution circuits.
  • Suitable for main incomer and high-current feeder protection.
  • Electronic protection supports coordinated distribution-system protection.
  • Part of ABB's established SACE Emax air circuit breaker platform.

Reliable LSIG Protection for High-Current Power Distribution

The ABB SACE Emax E2B-A is designed to provide switching, isolation and electronic circuit protection for substantial low-voltage distribution systems. Its 1600 A rating and three-pole architecture make it suitable for major three-phase circuits supplying industrial equipment, distribution boards and other high-current electrical loads.

The PR121/P-LSIG electronic release provides long-time protection against sustained overloads, short-time protection for short-circuit conditions, instantaneous protection against severe fault currents and earth-fault protection. Together, these functions provide comprehensive protection for applications requiring more functionality than LI or LSI trip-unit configurations.

Typical Applications

  • Main low-voltage electrical distribution switchboards.
  • Industrial manufacturing and process plants.
  • High-current incomer and feeder circuit protection.
  • Transformer-fed low-voltage distribution systems.
  • Commercial and infrastructure power distribution.
  • Three-phase switchgear requiring comprehensive electronic LSIG protection.

Technical Specifications

Series SACE Emax E2B-A
ABB order code 1SDA057281R1
Product type Air circuit breaker
Frame E2
Performance class B-A
Rated current 1600 A
Number of poles 3
Trip unit PR121/P-LSIG
Release type Electronic overcurrent release
Protection functions LSIG – long-time, short-time, instantaneous and earth-fault
Release rating R1600
ABB product group 310513-New Emax

Frequently Asked Questions

What is the ABB 1SDA057281R1?

The ABB 1SDA057281R1 is an E2B-A 1600 SACE Emax three-pole air circuit breaker rated at 1600 A and equipped with a PR121/P-LSIG electronic overcurrent release.

What is the rated current of the E2B-A 1600 PR121/P-LSIG?

The ABB E2B-A 1600 PR121/P-LSIG has a rated current of 1600 A and uses an R1600-rated PR121/P electronic release.

What protection functions does the PR121/P-LSIG provide?

The PR121/P-LSIG provides long-time overload protection, short-time short-circuit protection, instantaneous short-circuit protection and earth-fault protection.

How many poles does ABB 1SDA057281R1 have?

The ABB 1SDA057281R1 has a three-pole configuration suitable for three-phase low-voltage power distribution systems.

Does ABB 1SDA057281R1 provide earth-fault protection?

Yes. Its PR121/P-LSIG electronic release includes the G protection function for earth-fault protection in addition to long-time, short-time and instantaneous overcurrent protection.

Where is the ABB E2B-A 1600 PR121/P-LSIG typically used?

Typical applications include main low-voltage switchboards, industrial distribution systems, transformer-fed networks and high-current incomer or feeder circuits requiring comprehensive electronic LSIG protection.

Trusted by Electrical Engineers Worldwide

ABB SACE Emax air circuit breakers are engineered for demanding low-voltage power distribution applications, combining high current capability, advanced electronic protection and dependable switching performance for industrial, commercial and infrastructure installations.