1SDA057243R1 ABB E1B-A 1200 PR121/P-LSI 1200A 3P Air Circuit Breaker

1SDA057243R1 ABB E1B-A 1200 PR121/P-LSI 1200A 3P Air Circuit Breaker

ABB 1SDA057243R1 E1B-A 1200 PR121/P-LSI is a 1200 A three-pole SACE Emax air circuit breaker with LSI electronic overcurrent protection for high-current low-voltage power distribution systems.

SKU: 1SDA057243R1MPN: 1SDA057243R1
Price
List Price £9,524.23 ex VAT
Your Price (ex VAT) Save 25%
£7,143.17 25% OFF
You save £2,381.06 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,143.17
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,143.17

Why Choose the ABB E1B-A 1200 PR121/P-LSI 1200A 3P Air Circuit Breaker?

The ABB E1B-A 1200 PR121/P-LSI, order code 1SDA057243R1, is a high-performance SACE Emax air circuit breaker (ACB) designed for protection and switching in low-voltage power distribution systems. This three-pole model combines a 1200 A rated current with ABB's proven E1B-A circuit-breaker platform for industrial switchboards, distribution centres and other demanding electrical installations.

The breaker is equipped with an ABB PR121/P-LSI electronic overcurrent release, providing long-time, short-time and instantaneous protection functions. This LSI protection arrangement helps safeguard cables, busbars, switchgear and connected equipment against sustained overloads and short-circuit faults while supporting coordinated protection throughout the distribution network.

With its three-pole configuration and 1200 A current rating, the E1B-A 1200 PR121/P-LSI is suitable for high-current feeder and incomer duties. Its electronic protection technology and SACE Emax construction provide dependable circuit protection, switching and isolation for critical low-voltage electrical infrastructure.

Key Advantages

  • High-capacity 1200 A SACE Emax air circuit breaker for low-voltage power distribution.
  • Three-pole configuration for three-phase distribution circuits.
  • Advanced PR121/P-LSI electronic overcurrent release.
  • LSI functionality provides long-time, short-time and instantaneous protection.
  • Electronic protection supports selective coordination within complex distribution networks.
  • B performance level for dependable short-circuit protection.
  • Suitable for major incomer and feeder protection duties.
  • SACE Emax construction provides reliable switching, protection and circuit isolation.

Key Features

  • ABB SACE Emax E1B-A air circuit breaker.
  • 1200 A rated current.
  • Three-pole (3P) configuration.
  • PR121/P-LSI electronic protection release.
  • Long-time (L) overload protection.
  • Short-time (S) short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • B short-circuit performance level.
  • Electronic trip technology for accurate overcurrent protection.
  • Designed for industrial low-voltage power distribution systems.
  • Suitable for coordinated feeder and incomer protection.

Reliable LSI Protection for High-Current Distribution

Air circuit breakers such as the ABB SACE Emax E1B-A provide switching, isolation and overcurrent protection for important low-voltage distribution circuits. The electronic trip unit continuously monitors current conditions and initiates circuit interruption when configured protection thresholds are exceeded, helping prevent damage to electrical equipment and distribution infrastructure.

The PR121/P-LSI release combines long-time protection against sustained overloads with short-time and instantaneous protection against short-circuit currents. This combination allows protection settings to be coordinated with other protective devices in the network, supporting selectivity and helping minimise unnecessary interruption of unaffected circuits.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main incomer circuit protection.
  • High-current feeder protection.
  • Manufacturing and process plants.
  • Commercial and infrastructure power distribution.
  • Transformer secondary distribution systems.
  • Power distribution centres.
  • Low-voltage switchgear assemblies.

Technical Specifications

Series SACE Emax
ABB order code 1SDA057243R1
Product group 310513-New Emax
Product type Air circuit breaker (ACB)
Frame / size E1
Performance level B
Rated current (In) 1200 A
Number of poles 3P
Trip unit PR121/P-LSI electronic release
Protection functions Long-time (L), short-time (S), instantaneous (I)
Current type AC

Frequently Asked Questions

What is the ABB 1SDA057243R1 used for?

The ABB 1SDA057243R1 is a 1200 A three-pole SACE Emax air circuit breaker designed for protection, switching and isolation of high-current low-voltage power distribution circuits.

What trip unit is fitted to the ABB E1B-A 1200?

This circuit breaker is equipped with an ABB PR121/P-LSI electronic release, providing long-time, short-time and instantaneous overcurrent protection.

What is the rated current of the ABB 1SDA057243R1?

The E1B-A 1200 circuit breaker has a rated current of 1200 A.

What protection functions does PR121/P-LSI provide?

The PR121/P-LSI provides long-time overload protection together with short-time and instantaneous short-circuit protection.

Where is the ABB E1B-A 1200 typically used?

The breaker is typically used in industrial switchboards, main incomers, high-current feeders, power distribution centres and transformer secondary distribution systems.

Trusted Power Distribution Protection from ABB

ABB SACE Emax air circuit breakers provide dependable switching and electronic overcurrent protection for demanding low-voltage distribution systems, helping protect critical feeders, incomers and electrical infrastructure.