1SDA057239R1 ABB E1B-A 1200 PR121/P-LI 1200A 3-Pole Fixed Air Circuit Breaker

1SDA057239R1 ABB E1B-A 1200 PR121/P-LI 1200A 3-Pole Fixed Air Circuit Breaker

ABB 1SDA057239R1 SACE Emax E1B-A 1200 three-pole fixed UL air circuit breaker with a 1200 A rated current, PR121/P-LI R1200 electronic overcurrent release, 18000 A instantaneous protection setting and rear horizontal terminals.

SKU: 1SDA057239R1MPN: 1SDA057239R1
Price
List Price £8,858.89 ex VAT
Your Price (ex VAT) Save 25%
£6,644.17 25% OFF
You save £2,214.72 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,644.17
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,644.17

Why Choose the ABB E1B-A 1200 PR121/P-LI 1200A 3-Pole Fixed Air Circuit Breaker?

The ABB 1SDA057239R1 is a SACE Emax E1B-A air circuit breaker designed for switching and protection of substantial low-voltage electrical distribution circuits. Part of the ABB New Emax product range, this UL configuration combines a 1200 A current rating with the PR121/P-LI electronic overcurrent release for dependable protection in industrial, commercial and infrastructure power systems.

This three-pole fixed circuit breaker is equipped with rear horizontal terminals and the PR121/P-LI R1200 electronic overcurrent release. Its LI protection functions provide long-time overload (L) and instantaneous short-circuit (I) protection, with an instantaneous protection setting of 18,000 A for this specific configuration.

Designed for permanent installation within compatible switchgear, the 1SDA057239R1 also incorporates four auxiliary contacts and circuit-breaker open / closed position indication. Its combination of a 1200 A rating, electronic protection and fixed rear-horizontal connection arrangement makes it a practical solution for three-phase distribution systems requiring reliable high-current circuit protection.

Key Advantages

  • 1200 A rated current for substantial low-voltage distribution circuits.
  • Three-pole configuration for three-phase electrical systems.
  • Electronic PR121/P-LI R1200 overcurrent protection release.
  • LI protection provides long-time overload and instantaneous short-circuit protection.
  • 18,000 A instantaneous protection setting for this specific configuration.
  • Fixed installation for permanent integration into compatible switchgear.
  • Rear horizontal terminals for main circuit connections.
  • Four auxiliary contacts with circuit-breaker open / closed position indication.
  • UL configuration for applications designed around the corresponding certification framework.

Key Features

  • ABB SACE Emax E1B-A series.
  • 1200 A rated current.
  • 3-pole fixed air circuit breaker.
  • PR121/P-LI R1200 electronic trip unit.
  • Long-time overload (L) protection.
  • Instantaneous short-circuit (I) protection.
  • 18,000 A instantaneous protection setting.
  • Rear horizontal terminal arrangement.
  • Four auxiliary contacts.
  • Open / closed circuit-breaker position indication.
  • UL version.
  • ABB order code 1SDA057239R1.

Dependable Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax E1B-A 1200 provide switching and protection for high-current low-voltage distribution circuits. The electronic overcurrent release monitors current conditions and initiates circuit interruption when configured protection thresholds are exceeded, helping protect busbars, cables, transformers and connected equipment against damaging overload and short-circuit currents.

The PR121/P-LI release combines long-time overload and instantaneous short-circuit protection in a straightforward electronic protection package. Together with the E1B-A's 1200 A current rating, fixed construction, rear horizontal terminals and auxiliary status contacts, the 1SDA057239R1 provides a practical solution for switchboards requiring dependable three-phase circuit protection.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial electrical distribution systems.
  • Main incoming and feeder circuits.
  • Manufacturing and process plants.
  • Commercial building power distribution.
  • Infrastructure electrical systems.
  • Transformer secondary protection and switching.
  • Three-phase distribution systems requiring fixed air circuit breakers.

Technical Specifications

Series SACE Emax / New Emax
Order code 1SDA057239R1
Product group 310513-New Emax
Product type Air circuit breaker
Frame / variant E1B-A
Rated current (In) 1200 A
Number of poles 3
Trip unit PR121/P-LI R1200
Trip unit type Electronic overcurrent release
Protection functions Long-time overload and instantaneous short-circuit protection (LI)
Instantaneous protection setting (Im) 18,000 A
Installation Fixed circuit breaker
Terminal arrangement Rear horizontal
Configuration 3-pole fixed
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Net weight 40 kg
EAN 8015644595029
Customs tariff number 85362090
Certification version UL

Frequently Asked Questions

What is the ABB 1SDA057239R1 used for?

The ABB 1SDA057239R1 is a 1200 A three-pole fixed air circuit breaker designed for switching and protection of substantial low-voltage three-phase electrical distribution circuits.

What is the current rating of the ABB E1B-A 1200?

The E1B-A 1200 in this configuration has a rated current of 1200 A, making it suitable for high-current industrial, commercial and infrastructure distribution applications.

What protection unit is fitted to the ABB 1SDA057239R1?

The circuit breaker is fitted with an electronic ABB PR121/P-LI R1200 overcurrent release providing long-time overload and instantaneous short-circuit protection.

What is the instantaneous protection setting of the ABB 1SDA057239R1?

The 1SDA057239R1 is specified with an instantaneous protection setting of 18,000 A, identified as Im18000 in the ABB product configuration.

Is the ABB 1SDA057239R1 fixed or withdrawable?

The 1SDA057239R1 is a three-pole fixed air circuit breaker with rear horizontal terminals, four auxiliary contacts and circuit-breaker open / closed position indication.

Trusted Protection for Critical Power Systems

ABB SACE Emax air circuit breakers are engineered for dependable switching and protection in low-voltage power distribution systems, combining electronic overcurrent protection, robust construction and practical installation options for industrial, commercial and infrastructure applications.