1SDA057108R1 ABB E6V 5000 PR122/P-LSI 5000A 3P Fixed Air Circuit Breaker

1SDA057108R1 ABB E6V 5000 PR122/P-LSI 5000A 3P Fixed Air Circuit Breaker

ABB 1SDA057108R1 is a SACE Emax E6V 5000 A three-pole fixed air circuit breaker with rear horizontal terminals and a PR122/P-LSI R5000 electronic release providing long-time, short-time and instantaneous protection.

SKU: 1SDA057108R1MPN: 1SDA057108R1
Price
List Price £74,677.61 ex VAT
Your Price (ex VAT) Save 25%
£56,008.21 25% OFF
You save £18,669.40 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £56,008.21
Trade pricing is personalised to your account

Manufacturer Lead Time

£56,008.21

Why Choose the ABB E6V 5000 PR122/P-LSI 5000A 3P Fixed Air Circuit Breaker?

The ABB 1SDA057108R1 is a high-performance SACE Emax E6V air circuit breaker designed for protection and switching in demanding high-current low-voltage electrical distribution systems. Rated at 5000 A, this three-pole fixed breaker incorporates an ABB PR122/P-LSI R5000 electronic overcurrent release providing long-time overload, short-time delayed and instantaneous short-circuit protection.

As part of the proven ABB SACE Emax series, the E6V 5000 combines exceptional short-circuit performance with robust fixed switchboard construction. Its rear horizontal terminals provide a practical connection arrangement for permanent integration into industrial, infrastructure, utility and large commercial low-voltage distribution assemblies.

The E6V performance level provides an ultimate short-circuit breaking capacity of 150 kA at 415 V AC, 130 kA at 500 V AC and 100 kA at 690 V AC. Combined with a 100 kA short-time withstand current for 1 s, the breaker is well suited to major incoming and feeder circuits with high prospective fault currents.

Key Advantages

  • High-current 5000 A SACE Emax air circuit breaker for major power distribution systems.
  • Three-pole configuration for three-phase electrical networks.
  • Advanced PR122/P-LSI R5000 electronic overcurrent release.
  • LSI functionality provides long-time, short-time and instantaneous protection.
  • 150 kA ultimate breaking capacity at 415 V AC.
  • 100 kA ultimate breaking capacity at 690 V AC.
  • 100 kA short-time withstand current for 1 s.
  • Fixed construction with rear horizontal terminals for robust switchboard integration.

Key Features

  • ABB SACE Emax E6V air circuit breaker platform.
  • 5000 A rated uninterrupted current.
  • Three-pole configuration.
  • Fixed execution.
  • Rear horizontal terminals.
  • PR122/P-LSI R5000 electronic overcurrent release.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • 690 V AC rated operational voltage.
  • Four change-over auxiliary contacts.
  • Open/closed circuit-breaker position indication.

High-Performance Protection for Critical Power Distribution

Air circuit breakers such as the ABB SACE Emax E6V provide switching and overcurrent protection for major low-voltage distribution circuits. The electronic trip unit monitors current conditions and initiates circuit-breaker operation when configured overload or short-circuit thresholds are exceeded, helping protect busbars, cables, transformers and connected electrical equipment.

The PR122/P-LSI release combines long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection with the exceptional fault-interruption capability of the E6V frame. Its 150 kA Icu at 415 V AC makes this breaker particularly suitable for high-capacity distribution systems where very high prospective short-circuit currents can occur.

Typical Applications

  • Main incoming circuit breakers in high-current low-voltage switchboards.
  • Industrial power distribution systems.
  • High-capacity feeder protection.
  • Transformer secondary protection and switching.
  • Manufacturing and process plants.
  • Commercial and infrastructure power distribution.
  • Generator and utility distribution systems.
  • Fixed switchboard installations requiring high breaking capacity and LSI protection.

Technical Specifications

Series SACE Emax
Frame / type E6V
ABB order code 1SDA057108R1
EAN 8015644584481
Product type Air circuit breaker
Execution Fixed
Terminal connection Rear horizontal
Number of poles 3
Rated current (In) 5000 A
Rated uninterrupted current (Iu) 5000 A
Rated operational current (Ie) 5000 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Trip unit PR122/P-LSI R5000
Release type Electronic
Protection functions LSI – long-time, short-time and instantaneous
Overload release setting range 2000–5000 A
Instantaneous short-circuit setting range 7500–75000 A
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 130 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 100 kA
Service short-circuit breaking capacity (Ics) at 415 V AC 150 kA
Service short-circuit breaking capacity (Ics) at 500 V AC 100 kA
Service short-circuit breaking capacity (Ics) at 690 V AC 100 kA
Short-time withstand current (Icw), 1 s 100 kA
Short-time withstand current (Icw), 3 s 85 kA
Earth-fault protection No
Auxiliary contacts 4 change-over contacts
Position indication Circuit breaker open / closed
Motor drive Optional
Power loss 415 W
Electrical durability 3000 cycles at Ue ≤ 440 V; 2000 cycles at 500–690 V
Mechanical durability 12000 cycles
Product net dimensions (W × H × D) 782 × 418 × 302 mm
Product net weight 112 kg
Standard IEC
Product group 310513-New Emax

Frequently Asked Questions

What is the ABB 1SDA057108R1?

The ABB 1SDA057108R1 is a SACE Emax E6V 5000 A three-pole fixed air circuit breaker with rear horizontal terminals and a PR122/P-LSI R5000 electronic overcurrent release.

What protection functions does the PR122/P-LSI trip unit provide?

The PR122/P-LSI electronic release provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection.

What is the breaking capacity of the ABB E6V 5000?

The E6V 5000 has an ultimate short-circuit breaking capacity of 150 kA at 415 V AC, 130 kA at 500 V AC and 100 kA at 690 V AC.

What is the rated current of the ABB 1SDA057108R1?

The ABB 1SDA057108R1 has a rated uninterrupted current of 5000 A, making it suitable for major high-current low-voltage distribution circuits.

Is the ABB 1SDA057108R1 fixed or withdrawable?

The 1SDA057108R1 is a fixed circuit breaker equipped with rear horizontal terminals for permanent integration into a compatible low-voltage switchboard.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Emax air circuit breakers are engineered for reliable protection and switching in demanding low-voltage power distribution systems, combining high-current capability, advanced electronic protection and exceptional short-circuit performance.